Marginal Fit Evaluation of Zirconia Substructure Computer-Aided Design and Manufacturing (CAD/CAM) by Scanning Electron Microscope
被引:0
作者:
Abu-Ras, Kian
论文数: 0引用数: 0
h-index: 0
机构:
Tel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, IsraelTel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, Israel
Abu-Ras, Kian
[1
]
Dolev, Eran
论文数: 0引用数: 0
h-index: 0
机构:
Tel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, IsraelTel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, Israel
Dolev, Eran
[1
]
Biadsee, Ameer
论文数: 0引用数: 0
h-index: 0
机构:
Tel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, IsraelTel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, Israel
Biadsee, Ameer
[1
]
Ormianer, Zeev
论文数: 0引用数: 0
h-index: 0
机构:
Tel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, IsraelTel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, Israel
Ormianer, Zeev
[1
]
机构:
[1] Tel Aviv Univ, Sch Dent Med, Dept Oral Rehabil, POB 3904, Tel Aviv, Israel
Purpose. This in vitro study compared the vertical marginal discrepancy (MD) and absolute marginal discrepancy (AMD) between the zirconia substructure and titanium (Ti)-base abutment before and after cementation. Material and methods. An intraoral scanner (CEREC Omnicam scanner; Dentsply Sirona) was used to scan the dental model of missing tooth 36 and obtain a three-dimensional virtual model. It was designed and milled for 25 zirconia superstructures (inCoris ZI meso F2 L, Dentsply Sirona). The samples were cemented to Ti bases. The MD and AMD were measured for each sample by using a scanning electron microscope (SEM) before and after cementation. Results. The overall mean values of MD measurements before and after cementation were 14.12 mu m and 20.28 mu m, respectively. The overall mean values of AMD measurements prior to and after substructure cementation on the Ti base were 54.85 mu m and 116.0 mu m, respectively. ANOVA revealed significant differences in MD (p = 0.001) and AMD (p < 0.001) before and after cementation. Conclusions. Significant differences were observed in MD and AMD values before and after cementation. The MD and AMD values were significantly lower before cementation than after cementation. The mean MD and AMD values were clinically acceptable.
机构:
Ajman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, SwitzerlandAjman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
Afrashtehfar, Kelvin I.
;
Weber, Adrian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Removable Prosthodont, Bern, SwitzerlandAjman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
Weber, Adrian
;
Abou-Ayash, Samir
论文数: 0引用数: 0
h-index: 0
机构:
Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dent, Bern, SwitzerlandAjman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
机构:
Jordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
Univ Sharjah, Sharjah, U Arab EmiratesJordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
Al-Quran, Firas A.
;
Al-Ghalayini, Raed F.
论文数: 0引用数: 0
h-index: 0
机构:
Shemesani Dent Ctr, Amman 11121, JordanJordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
Al-Ghalayini, Raed F.
;
Al-Zu'bi, Bashar N.
论文数: 0引用数: 0
h-index: 0
机构:
Al Jouf Univ, Coll Dent, Al Jouf Skaka, Saudi ArabiaJordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
机构:
Univ Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, MalaysiaUniv Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, Malaysia
Baig, Mirza Rustum
;
Tan, Keson Beng-Choon
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ Singapore, Dept Restorat Dent, Fac Dent, Singapore 117548, SingaporeUniv Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, Malaysia
Tan, Keson Beng-Choon
;
Nicholls, Jack I.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Washington, Dept Restorat Dent, Sch Dent, Seattle, WA 98195 USAUniv Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, Malaysia
机构:
Ajman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, SwitzerlandAjman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
Afrashtehfar, Kelvin I.
;
Weber, Adrian
论文数: 0引用数: 0
h-index: 0
机构:
Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Removable Prosthodont, Bern, SwitzerlandAjman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
Weber, Adrian
;
Abou-Ayash, Samir
论文数: 0引用数: 0
h-index: 0
机构:
Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Sect Digital Implant & Reconstruct Dent, Bern, SwitzerlandAjman Univ, Clin Sci Dept, Evidence Based Practice Unit, Coll Dent, Ajman, U Arab Emirates
机构:
Jordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
Univ Sharjah, Sharjah, U Arab EmiratesJordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
Al-Quran, Firas A.
;
Al-Ghalayini, Raed F.
论文数: 0引用数: 0
h-index: 0
机构:
Shemesani Dent Ctr, Amman 11121, JordanJordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
Al-Ghalayini, Raed F.
;
Al-Zu'bi, Bashar N.
论文数: 0引用数: 0
h-index: 0
机构:
Al Jouf Univ, Coll Dent, Al Jouf Skaka, Saudi ArabiaJordan Univ Sci & Technol, Fac Dent, Irbid 22110, Jordan
机构:
Univ Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, MalaysiaUniv Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, Malaysia
Baig, Mirza Rustum
;
Tan, Keson Beng-Choon
论文数: 0引用数: 0
h-index: 0
机构:
Natl Univ Singapore, Dept Restorat Dent, Fac Dent, Singapore 117548, SingaporeUniv Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, Malaysia
Tan, Keson Beng-Choon
;
Nicholls, Jack I.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Washington, Dept Restorat Dent, Sch Dent, Seattle, WA 98195 USAUniv Malaya, Dept Prosthet Dent, Fac Dent, Kuala Lumpur 50603, Malaysia