Evaluation of the Image Quality of Ultra-Low-Dose Paranasal Sinus CT

被引:0
作者
Aksamoglu, Melih [1 ]
Menzilcioglu, Mehmet Sait [1 ]
机构
[1] Gaziantep Univ, Dept Radiol, Fac Med, Gaziantep, Turkiye
来源
EUROPEAN JOURNAL OF THERAPEUTICS | 2023年 / 29卷 / 02期
关键词
Multidetector Computed Tomography; Paranasal Sinus; Radiation Exposure;
D O I
10.58600/eurjther.20232902-1131.y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: We aimed to investigate the image quality of paranasal sinus computed tomography (CT) scans obtained with the "Advanced intelligent Clear-IQ Engine" (AiCE) software and ultra-low dose parameters in patients with pre-diagnosed rhinitis, sinusitis or nasal septum deviation. Methods: The first 50 patients (31 men and 19 women, aged 18-70 years) who agreed to participate in our prospectively planned study were included in the study. Imaging of the patients was performed with a 160-slice multidetector CT device Canon Aquilion Prime SP (Canon Medical Systems, Otawara, Japan). Tube voltage of 80 kV and tube current of 40 mA were chosen. The effective radiation dose (ED) was calculated based on the "dose-length product"(DLP) information of each patient. Evaluation of images was made on reformat images made with "AiCE Bone" filter in the axial and coronal planes. All images were double-blindly evaluated by 2 radiologists out of 5 points (5 = very good; 1 = not diagnostic). The visibility of 17 bilateral important anatomical landmarks examined on paranasal sinus CT was scored (0 = not visible; 2 = completely visible). In the evaluation of images, the agreement between radiologists was evaluated with Kappa statistics. Results: The median ED value of the CT protocol was 0.015 +/- 0.001 mSv [range 0.012-0.017 mSv]. The overall image quality of the images in our study was interpreted as 4 (good) or 3 (moderate) for all patients. Inter-research agreement was 92%. Most of the anatomical landmarks evaluated were completely visible. Six (bilateral of three) anatomical landmarks could be partially visible in some patients. Conclusion: Combining the ultra-low dose CT protocol and the AiCE reconstruction algorithm makes it possible to achieve very low ED values in paranasal sinus CT scans and still obtain sufficient image quality in indications such as septum deviation and sinusitis.
引用
收藏
页码:143 / 148
页数:6
相关论文
共 12 条
  • [1] Reliability of High-Pitch Ultra-Low-Dose Paranasal Sinus Computed Tomography for Evaluating Paranasal Sinus Anatomy and Sinus Disease
    Aksoy, Elif Ayanoglu
    Ozden, Sila Ulus
    Karaarslan, Ercan
    Unal, Omer Faruk
    Tanyeri, Hasan
    [J]. JOURNAL OF CRANIOFACIAL SURGERY, 2014, 25 (05) : 1801 - 1804
  • [2] Seventy kilovolt ultra-low dose CT of the paranasal sinus: first clinical results
    Bodelle, B.
    Wichmann, J. L.
    Klotz, N.
    Lehnert, T.
    Vogl, T. J.
    Luboldt, W.
    Schulz, B.
    [J]. CLINICAL RADIOLOGY, 2015, 70 (07) : 711 - 715
  • [3] Bongartz G., 1999, European Guidelines on Quality Criteria for Computed Tomography
  • [4] Multidetector CT of the paranasal sinus: Potential for radiation dose reduction
    Brem, Matthias H.
    Zamani, Amir A.
    Riva, Roberto
    Zou, Kelly H.
    Rumboldt, Zoran
    Hennig, Friedrich F.
    Kikinis, Ron
    Norbash, Alexander M.
    Schoepf, U. Joseph
    [J]. RADIOLOGY, 2007, 243 (03) : 847 - 852
  • [5] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [6] Organ doses, effective dose, and radiation risk assessment in radiography of pediatric paranasal sinuses (Waters view)
    Chaparian, Ali
    Tavakoli, Iman
    Karimi, Vahid
    [J]. ASIAN BIOMEDICINE, 2013, 7 (05) : 695 - 698
  • [7] Targeted and non-targeted effects of ionizing radiation
    Desouky, Omar
    Ding, Nan
    Zhou, Guangming
    [J]. JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2015, 8 (02) : 247 - 254
  • [8] Optimization of paranasal sinus CT procedure: Ultra-low dose CT as a roadmap for pre-functional endoscopic sinus surgery
    Diklic, Ana
    Zujic, Petra Valkovic
    Segota, Doris
    Debeljuh, Dea Dundara
    Jurkovic, Slaven
    Brambilla, Marco
    Kalra, Mannudeep K.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 78 : 195 - 200
  • [9] CT scanning of the paranasal sinuses - the effect of reducing mAs
    Kearney, SE
    Jones, P
    Meakin, K
    Garvey, CJ
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1997, 70 (838) : 1071 - 1074
  • [10] The Preoperative Sinus CT: Avoiding a "CLOSE" Call with Surgical Complications
    O'Brien, William T.
    Hamelin, Stefan
    Weitzel, Erik K.
    [J]. RADIOLOGY, 2016, 281 (01) : 10 - 21