Anatomical and imaging measurements of the angle between the axis of the lumbar pedicle and lateral isthmus margin and its clinical significance

被引:0
|
作者
Wang, Shuiquan [1 ]
Aikeremu, Dilimulati [2 ]
Kahaer, Alafate [3 ]
Maimaiti, Abulikemu [3 ]
Xiao, Yang [3 ]
Tuoheti, Abudusalamu [3 ]
Zhang, Rui [3 ]
Maimaiti, Xieraili [3 ]
Guo, Hailong [3 ]
Rexiti, Paerhati [3 ]
机构
[1] Xinjiang Med Univ, Coll Basic Med, Dept Anat, Urumqi, Peoples R China
[2] Peoples Hosp Xinjiang, Dept Spine Surg 2, Urumqi, Peoples R China
[3] Xinjiang Med Univ, Affiliated Hosp 1, Dept Spine Surg, Urumqi, Peoples R China
关键词
Pedicle axis; Lateral margin of isthmus; Angle; Pedicle screw; FACET JOINT OSTEOARTHRITIS; LOW-BACK-PAIN; SPINE;
D O I
10.1186/s13018-023-03983-3
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
BackgroundThis study aims to explore the measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar spine, and investigate its clinical significance.MethodsThe angle was measured on 120 normal adults' X-ray and 25 dry anatomical specimens. 60 screws were placed by junior residents on 6 wet specimens through the freehand technique. 30 screws were placed on one side with their original experience. After learning the techniques mentioned in the study, 30 screws were placed on the other side. The specimens were examined by X-ray and CT, and the angles of the screw paths and the integrity of the pedicle were evaluated.ResultsThe angles of 120 subjects and 25 anatomical specimens show a gradually increasing trend. The differences among each segment were statistically significant (P < 0.05), but the difference in the same segment between the X-ray and the anatomical specimens was not statistically significant (P > 0.05). Furthermore, the differences in L1, L2, and L3 between the two genders were not statistically significant (P > 0.05). However, the angles were larger in female group than in male group in L4 and L5, and the differences were statistically significant (P < 0.05). The difference in the deviation rate of screw placement before and after the learning was statistically significant only in the L5 segment (P < 0.05). The difference in overall excellence rate was statistically significant (P < 0.05).ConclusionsThe measurement of the angle between the axis of the pedicle and the lateral margin of the isthmus on the lumbar can improve the accuracy of the lumbar sagittal screw angle.
引用
收藏
页数:9
相关论文
共 3 条
  • [1] Anatomical and imaging measurements of the angle between the axis of the lumbar pedicle and lateral isthmus margin and its clinical significance
    Shuiquan Wang
    Dilimulati Aikeremu
    Alafate Kahaer
    Abulikemu Maimaiti
    Yang Xiao
    Abudusalamu Tuoheti
    Rui Zhang
    Xieraili Maimaiti
    Hailong Guo
    Paerhati Rexiti
    Journal of Orthopaedic Surgery and Research, 18
  • [2] Clinical Significance of Lateral Pedicle Screw Malposition in Lumbar Spine Fusion
    LeRoy, Taryn E.
    Smith, Isabel C.
    Kim, David H.
    Golenbock, Samuel W.
    Baker, Kevin C.
    Arnold, Paul M.
    Sasso, Rick C.
    Park, Daniel K.
    Fischgrund, Jeffrey S.
    Zaidi, Qasim H.
    Hwang, Raymond W.
    CLINICAL SPINE SURGERY, 2023, 36 (06): : E258 - E262
  • [3] A description of the lumbar interfascial triangle and its relation with the lateral raphe: anatomical constituents of load transfer through the lateral margin of the thoracolumbar fascia
    Schuenke, M. D.
    Vleeming, A.
    Van Hoof, T.
    Willard, F. H.
    JOURNAL OF ANATOMY, 2012, 221 (06) : 568 - 576