Scaling Study of Smoke Spread from Building Integrated Photovoltaic (BIPV) Double Skin Facade Fire for Achieving Sustainable Buildings and Cities

被引:4
|
作者
Aram, Monireh [1 ]
Zhang, Xin [1 ]
Qi, Dahai [1 ]
Ko, Yoon [1 ]
机构
[1] Univ Sherbrooke, Dept Civil & Bldg Engn, 2500 Boul Univ, Sherbrooke, PQ J1K 2R1, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会;
关键词
Scaling method; helium smoke; sustainable design; BIPV DSF fires; smoke spread; ROOM FIRE; VENTILATION; VALIDATION; SIMULATION; HELIUM; CAVITY;
D O I
10.1016/j.scs.2023.104648
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Due to the shift to sustainable design of buildings and cities, the building integrated photovoltaic (BIPV) is getting more attention. However, this technology may bring new challenges to safety in buildings and cities, i.e., fire safety issues regarding BIPV fire induced smoke propagation in double skin facades (DSF). To study this phenomenon, it is essential to conduct experiments, in which full-scale fire experiments are often inefficient regarding economics and safety. To cope with these issues, this study proposes a new scaling method, which applies the helium sub-scale tests to replace full-scale fire smoke tests for buildings with DSF during BIPV fires. To verify this scaling method, three groups of cases are defined and simulated by fire dynamic simulator (FDS), i. e., full-scale with fire (FSF), small-scale with fire (SSF) and small-scale with helium (SSH). Then, a small-scale experimental model is constructed to validate the FDS model. At last, the simulation results are compared among SSH, SSF and FSF cases, which show acceptable agreement. Therefore, the new scaling method of smoke spread from BIPV DSF fires is justified, which can be applied to the study of BIPV DFS fires induced smoke control in urban scale.
引用
收藏
页数:13
相关论文
共 6 条
  • [1] Optimising Design Parameters of a Building-Integrated Photovoltaic Double-Skin Facade in Different Climate Zones in Australia
    Yang, Siliang
    Fiorito, Francesco
    Sproul, Alistair
    Prasad, Deo
    BUILDINGS, 2023, 13 (04)
  • [2] A comparative study on thermal performance evaluation of a new double skin facade system integrated with photovoltaic blinds
    Luo, Yongqiang
    Zhang, Ling
    Wang, Xiliang
    Xie, Lei
    Liu, Zhongbing
    Wu, Jing
    Zhang, Yelin
    He, Xihua
    APPLIED ENERGY, 2017, 199 : 281 - 293
  • [3] Investigation of burning photovoltaic panels on a double-skin facade with ejecting flame from an adjacent room fire
    Miao, Lei
    Chow, Cheuk-Lun
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (07) : 938 - 949
  • [4] Quasi-dynamic energy performance analysis of building integrated photovoltaic thermal double skin facade for middle eastern climate case
    Shakouri, Mahdi
    Ghadamian, Hossein
    Noorpoor, Alireza
    APPLIED THERMAL ENGINEERING, 2020, 179
  • [5] Upward Fire Spread Hazard of Vertical Greenery Systems: A Comparative Study with External Thermal Insulation Composite System and Double-Skin Facade
    Karunaratne, Tharindu Lakruwan Wickremanayake
    Chow, Cheuk Lun
    FIRE-SWITZERLAND, 2023, 6 (05):
  • [6] Similarity assessment of using helium to predict smoke movement through buildings with double skin fa?ades during building integrated photovoltaics fires
    Aram, Monireh
    Zhang, Xin
    Reda, Ibrahim
    Dghim, Marouen
    Qi, Dahai
    Ko, Yoon
    JOURNAL OF CLEANER PRODUCTION, 2023, 405