Pneumocystis jirovecii Pneumonia Diagnostic Approach: Real-Life Experience in a Tertiary Centre

被引:9
作者
Veintimilla, Cristina [1 ,2 ]
Alvarez-Uria, Ana [1 ,2 ]
Martin-Rabadan, Pablo [1 ,2 ,3 ]
Valerio, Maricela [1 ,2 ,4 ]
Machado, Marina [1 ,2 ]
Padilla, Belen [1 ,2 ]
Alonso, Roberto [1 ,2 ,4 ]
Diez, Cristina [1 ,2 ,5 ]
Munoz, Patricia [1 ,2 ,3 ,4 ]
Marin, Mercedes [1 ,2 ,3 ,4 ]
机构
[1] Hosp Gen Univ Gregorio Maranon, Dept Clin Microbiol & Infect Dis, Madrid 28007, Spain
[2] Inst Invest Sanitaria Gregorio Maranon, Madrid 28009, Spain
[3] CIBER Enfermedades Resp CIBERES CB06 06 0058, Madrid 08036, Spain
[4] UCM, Sch Med, Med Dept, Madrid 28040, Spain
[5] Inst Salud Carlos III, Ctr Invest Biomed Red Enfermedades Infecciosas CIB, Madrid 28220, Spain
关键词
Pneumocystis jirovecii pneumonia; indirect immunofluorescence; staining; polymerase chain reaction (PCR); diagnostic accuracy; immunocompromised host; HIV-INFECTED PATIENTS; TIME PCR ASSAY; CARINII-PNEUMONIA; QUANTITATIVE PCR; COLONIZATION; DIFFERENTIATION; SPECIMENS; MORTALITY; DNA;
D O I
10.3390/jof9040414
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Pneumocystis jirovecii pneumonia (PJP) in immunocompromised patients entails high mortality and requires adequate laboratory diagnosis. We compared the performance of a real time-PCR assay against the immunofluorescence assay (IFA) in the routine of a large microbiology laboratory. Different respiratory samples from HIV and non-HIV-infected patients were included. The retrospective analysis used data from September 2015 to April 2018, which included all samples for which a P. jirovecii test was requested. A total of 299 respiratory samples were tested (bronchoalveolar lavage fluid (n = 181), tracheal aspirate (n = 53) and sputum (n = 65)). Forty-eight (16.1%) patients fulfilled the criteria for PJP. Five positive samples (10%) had only colonization. The PCR test was found to have a sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of 96%, 98%, 90% and 99%, compared to 27%, 100%, 100% and 87%, for the IFA, respectively. PJ-PCR sensitivity and specificity were >80% and >90% for all tested respiratory samples. Median cycle threshold values in definite PJP cases were 30 versus 37 in colonized cases (p < 0.05). Thus, the PCR assay is a robust and reliable test for the diagnosis PJP in all respiratory sample types. Ct values of >= 36 could help to exclude PJP diagnosis.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] Diagnosis model of early Pneumocystis jirovecii pneumonia based on convolutional neural network: a comparison with traditional PCR diagnostic method
    Li, Yingying
    Liu, Hailin
    Lv, Qingwen
    Long, Jun
    [J]. BMC PULMONARY MEDICINE, 2024, 24 (01)
  • [42] Epidemiology and real-life experience in progressive pulmonary fibrosis
    Valenzuela, Claudia
    Cottin, Vincent
    [J]. CURRENT OPINION IN PULMONARY MEDICINE, 2022, 28 (05) : 407 - 413
  • [43] Pneumocystis jiroveci pneumonia in rheumatic disease: a 20-year single-centre experience
    Mecoli, C. A.
    Saylor, D.
    Gelber, A. C.
    Christopher-Stine, L.
    [J]. CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2017, 35 (04) : 671 - 673
  • [44] The conventional diagnosis challenge: Real-time PCR and nested PCR correlation with the scoring system for individuals at high-risk of Pneumocystis jirovecii pneumonia
    Almeida-Silva, Fernando
    Almeida-Paes, Rodrigo
    Serra-Damasceno, Lisandra
    Motta-Santos, Edwiges
    Ferreira, Luiz Claudio
    Pereira-Quintella, Leonardo
    de Faria Ferreira, Marcela
    de Medeiros-Muniz, Mauro
    Zancope-Oliveira, Rosely M.
    [J]. BIOMEDICA, 2023, 43 : 255 - 266
  • [45] Pneumocystis jirovecii dihydropteroate synthase (DHPS) genotypes in non-HIV-immunocompromised patients: a tertiary care reference health centre study
    Tyagi, A. K.
    Mirdha, B. R.
    Luthra, K.
    Guleria, R.
    Mohan, A.
    Singh, U. B.
    Samantaray, J. C.
    Dar, L.
    Iyer, V. K.
    Sreenivas, V.
    [J]. MEDICAL MYCOLOGY, 2011, 49 (02) : 167 - 171
  • [46] Comparison of PneumID real-time PCR assay with Amplex eazyplex LAMP assay for laboratory diagnosis of Pneumocystis jirovecii Pneumonia
    Ng, Willy W. Y.
    Ho, Yolanda I. I.
    Wong, Ann H.
    Leung, Eddie C. M.
    Lee, Alfred L. H.
    Chow, Viola C. Y.
    [J]. MEDICAL MYCOLOGY, 2022, 60 (06)
  • [47] Diagnostic values of BALF metagenomic next-generation sequencing, BALF real-time PCR and serum BDG for Pneumocystis jirovecii pneumonia in HIV-infected patients
    Chen, Qianhui
    Chen, Xiaoping
    Mo, Pingzheng
    Chen, Liangjun
    Du, Qian
    Hu, Wenjia
    Jiang, Qunqun
    Zhang, Zhongwei
    Zhang, Yongxi
    Guo, Qinglian
    Xiong, Yong
    Deng, Liping
    [J]. FRONTIERS IN MICROBIOLOGY, 2024, 15
  • [48] Prophylactic effect of low-dose trimethoprim-sulfamethoxazole for Pneumocystis jirovecii pneumonia in adult recipients of kidney transplantation: a real-world data study
    Chen, Ruo-Yang
    Li, Da-Wei
    Wang, Jie-Ying
    Zhuang, Shao-Yong
    Wu, Hao-Yu
    Wu, Jia-Jin
    Qu, Jun-Wen
    Sun, Nan
    Zhong, Chen
    Zhu, Cheng
    Zhang, Ming
    Yu, Yue-Tian
    Yuan, Xiao-Dong
    [J]. INTERNATIONAL JOURNAL OF INFECTIOUS DISEASES, 2022, 125 : 209 - 215
  • [49] Pneumocystis Jirovecii detection and comparison of multiple diagnostic methods with quantitative real-time PCR in patients with respiratory symptoms
    Alshahrani, Mohammad Y.
    Alfaifi, Mohammed
    Ahmad, Irfan
    Alkhathami, Ali Gaithan
    Hakami, Abdulrahim Refdan
    Ahmad, Hafiz
    Alshehri, Osama M.
    Dhakad, Megh Singh
    [J]. SAUDI JOURNAL OF BIOLOGICAL SCIENCES, 2020, 27 (06) : 1423 - 1427
  • [50] Clinical efficacy and safety of cefiderocol for resistant Gram-negative infections: a real-life, single-centre experience
    Karruli, Arta
    Massa, Alessia
    Andini, Roberto
    Marrazzo, Tommaso
    Ruocco, Giuseppe
    Zampino, Rosa
    Durante-Mangoni, Emanuele
    [J]. INTERNATIONAL JOURNAL OF ANTIMICROBIAL AGENTS, 2023, 61 (02)