Assessment of indoor air quality and their inter-association in hospitals of northern India-a cross-sectional study

被引:14
作者
Taushiba, Anam [1 ,2 ]
Dwivedi, Samridhi [1 ]
Zehra, Farheen [1 ]
Shukla, Pashupati Nath [3 ]
Lawrence, Alfred J. [1 ]
机构
[1] Isabella Thoburn Coll, Dept Chem, Lucknow, India
[2] Integral Univ, Dept Environm Sci, Lucknow, India
[3] Natl Bot Res Inst, Dept Pharmacol & Microbial Technol, Lucknow, India
关键词
Indoor air quality; Nosocomial infection; Exposure; Mold; Bacteria; Indoor pollution; PARTICULATE MATTER; HEAVY-METALS; MICROBIOLOGICAL ASSESSMENT; BIOAEROSOL EXPOSURE; RISK-ASSESSMENT; HEALTH; BURDEN; IMPACT; PM2.5; CONTAMINATION;
D O I
10.1007/s11869-023-01321-4
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study was commenced to evaluate the indoor and outdoor air quality concentrations of PM2.5, sub-micron particles (PM>2.5, PM1.0-2.5, PM0.50 -1.0, PM0.25-0.50, and PM<0.25), heavy metals, and microbial contaminants along with their identification in three different hospitals of Lucknow City. The study was conducted from February 2022 to April 2022 in hospitals situated in the commercial, residential, and industrial belts of the city. The indoor concentration trend of particulate matter as observed during the study suggested that most of the highest concentrations belonged to the hospital situated in an industrial area. The highest obtained indoor and outdoor concentrations for PM1.0-2.5, PM0.50-1.0, PM0.25-0.50, and PM<0.25 are 40.44 mu g/m(3), 56.08 mu g/m(3), 67.20 mu g/m(3), 74.50 mu g/m(3), 61.9 mu g/m(3), 79.3 mu g/m(3), 82.0 mu g/m(3), and 93.9 mu g/m(3), respectively, which belonged to hospital C situated in the industrial belt. However, for PM>2.5, the highest indoor concentration obtained belonged to hospital B, i.e., 30.7 mu g/m(3), which is situated in the residential belt of the city. Regarding PM2.5, the highest indoor and outdoor concentrations obtained are 149.41 mu g/m(3) and 227.45 mu g/m(3), which were recorded at hospital A and hospital C, respectively. The present study also observed that a high bacterial load of 1389.21 CFU/m(3) is recorded in hospital B, and the fungi load was highest in hospital C with 786.34 CFU/m(3). Henceforth, the present study offers thorough information on the various air pollutants in a crucial indoor setting, which will further aid the researchers in the field to identify and mitigate the same more precisely.
引用
收藏
页码:1023 / 1036
页数:14
相关论文
共 70 条
[1]   Cadmium exposure and cancer mortality in the Third National Health and Nutrition Examination Survey cohort [J].
Adams, Scott V. ;
Passarelli, Michael N. ;
Newcomb, Polly A. .
OCCUPATIONAL AND ENVIRONMENTAL MEDICINE, 2012, 69 (02) :153-156
[2]   Indoor bacterial load and its correlation to physical indoor air quality parameters in public primary schools [J].
Andualem, Zewudu ;
Gizaw, Zemichael ;
Bogale, Laekemariam ;
Dagne, Henok .
MULTIDISCIPLINARY RESPIRATORY MEDICINE, 2019, 14
[3]  
[Anonymous], 1989, EPA540189002
[4]   Epidemiological time series studies of PM2.5 and daily mortality and hospital admissions: a systematic review and meta-analysis [J].
Atkinson, R. W. ;
Kang, S. ;
Anderson, H. R. ;
Mills, I. C. ;
Walton, H. A. .
THORAX, 2014, 69 (07) :660-665
[5]   Environmental contamination and hospital-acquired infection: factors that are easily overlooked [J].
Beggs, C. ;
Knibbs, L. D. ;
Johnson, G. R. ;
Morawska, L. .
INDOOR AIR, 2015, 25 (05) :462-474
[6]   VOC Contamination in Hospital, from Stationary Sampling of a Large Panel of Compounds, in View of Healthcare Workers and Patients Exposure Assessment [J].
Bessonneau, Vincent ;
Mosqueron, Luc ;
Berrube, Adele ;
Mukensturm, Gael ;
Buffet-Bataillon, Sylvie ;
Gangneux, Jean-Pierre ;
Thomas, Olivier .
PLOS ONE, 2013, 8 (02)
[7]  
Bhattacharya T., 2013, OJMETAL, V3, P42, DOI [10.4236/ojmetal.2013.32A1006, DOI 10.4236/OJMETAL.2013.32A1006, 10.4236/ojmetal.2013.32a1006]
[8]   Heavy metal concentration and its distribution analysis in urban road dust: A case study from most populated city of Indian state of Uttarakhand [J].
Bisht, Lalita ;
Gupta, Vidhu ;
Singh, Ajay ;
Gautam, Alok Sagar ;
Gautam, Sneha .
SPATIAL AND SPATIO-TEMPORAL EPIDEMIOLOGY, 2022, 40
[9]   Assessment of bioaerosol particle characteristics at different hospital wards and operating theaters: A case study in Tehran [J].
Bolookat, Fatemeh ;
Hassanvand, Mohammad Sadegh ;
Faridi, Sasan ;
Hadei, Mostafa ;
Rahmatini, Masoumeh ;
Alimohammadi, Mahmood .
METHODSX, 2018, 5 :1588-1596
[10]   Characterization of the gastrointestinal yeast microbiota of cockatiels (Nymphicus hollandicus): a potential hazard to human health [J].
Brilhante, R. S. N. ;
Castelo-Branco, D. S. C. M. ;
Soares, G. D. P. ;
Astete-Medrano, D. J. ;
Monteiro, A. J. ;
Cordeiro, R. A. ;
Sidrim, J. J. C. ;
Rocha, M. F. G. .
JOURNAL OF MEDICAL MICROBIOLOGY, 2010, 59 (06) :718-723