Upper Limb Joint Angle Estimation Using Wearable IMUs and Personalized Calibration Algorithm

被引:4
|
作者
Rahman, Md. Mahmudur [1 ,2 ]
Gan, Kok Beng [3 ]
Abd Aziz, Noor Azah [4 ]
Huong, Audrey [5 ]
You, Huay Woon [6 ]
机构
[1] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Bangi 43600, Malaysia
[2] Daffodil Int Univ, Dept Elect & Elect Engn, Dhaka 1216, Bangladesh
[3] Univ Kebangsaan Malaysia, Dept Elect Elect & Syst Engn, Med Engn & Syst Res Grp, Bangi 43600, Malaysia
[4] Univ Kebangsaan Malaysia, Fac Med, Dept Family Med, Med Ctr, Kuala Lumpur 56000, Malaysia
[5] Univ Tun Hussein Onn Malaysia, Dept Elect Engn, Parit Raja 86400, Malaysia
[6] Univ Kebangsaan Malaysia, Pusat GENIUSPintar Negara, Bangi 43600, Malaysia
关键词
inertial measurement unit; accelerometer; gyroscope; magnetometer; electro-goniometer; joint angle; rigid body; sensor fusion; Madgwick filter; Kalman filter; COMPLEMENTARY FILTER; OPTIMIZATION; GYROSCOPES;
D O I
10.3390/math11040970
中图分类号
O1 [数学];
学科分类号
0701 ; 070101 ;
摘要
In physical therapy, exercises improve range of motion, muscle strength, and flexibility, where motion-tracking devices record motion data during exercises to improve treatment outcomes. Cameras and inertial measurement units (IMUs) are the basis of these devices. However, issues such as occlusion, privacy, and illumination can restrict vision-based systems. In these circumstances, IMUs may be employed to focus on a patient's progress quantitatively during their rehabilitation. In this study, a 3D rigid body that can substitute a human arm was developed, and a two-stage algorithm was designed, implemented, and validated to estimate the elbow joint angle of that rigid body using three IMUs and incorporating the Madgwick filter to fuse multiple sensor data. Two electro-goniometers (EGs) were linked to the rigid body to verify the accuracy of the joint angle measuring algorithm. Additionally, the algorithm's stability was confirmed even in the presence of external acceleration. Multiple trials using the proposed algorithm estimated the elbow joint angle of the rigid body with a maximum RMSE of 0.46 degrees. Using the IMU manufacturer's (WitMotion) algorithm (Kalman filter), the maximum RMSE was 1.97 degrees. For the fourth trial, joint angles were also calculated with external acceleration, and the RMSE was 0.996 degrees. In all cases, the joint angles were within therapeutic limits.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] FDA-MIMO for joint angle and range estimation: unfolded coprime framework and parameter estimation algorithm
    Wang, Cheng
    Li, Zheng
    Zhang, Xiaofei
    IET RADAR SONAR AND NAVIGATION, 2020, 14 (06) : 917 - 926
  • [22] Estimation of Individual Muscular Forces of the Lower Limb during Walking Using a Wearable Sensor System
    Kim, Suin
    Ro, Kyongkwan
    Bae, Joonbum
    JOURNAL OF SENSORS, 2017, 2017
  • [23] Joint Angle Estimation Using Accelerometer Arrays and Model-Based Filtering
    Woods, Cole
    Vikas, Vishesh
    IEEE SENSORS JOURNAL, 2022, 22 (20) : 19786 - 19796
  • [24] Estimation of Elbow Joint Angle from Surface Electromyogram Signals Using ANFIS
    Rajalakshmy, P.
    Jacob, Elizabeth
    Sharon, T. Joclyn
    COMPUTER AIDED INTERVENTION AND DIAGNOSTICS IN CLINICAL AND MEDICAL IMAGES, 2019, 31 : 247 - 253
  • [25] Instrumented Ergonomic Risk Assessment Using Wearable Inertial Measurement Units: Impact of Joint Angle Convention
    Humadi, Ahmed
    Nazarahari, Milad
    Ahmad, Rafiq
    Rouhani, Hossein
    IEEE ACCESS, 2021, 9 : 7293 - 7305
  • [26] Estimation of Lower Limb Joint Angles and Joint Moments during Different Locomotive Activities Using the Inertial Measurement Units and a Hybrid Deep Learning Model
    Wang, Fanjie
    Liang, Wenqi
    Afzal, Hafiz Muhammad Rehan
    Fan, Ao
    Li, Wenjiong
    Dai, Xiaoqian
    Liu, Shujuan
    Hu, Yiwei
    Li, Zhili
    Yang, Pengfei
    SENSORS, 2023, 23 (22)
  • [27] Joint estimation of source number and DOA using simulated annealing algorithm
    Liang, Junli
    Liu, Ding
    DIGITAL SIGNAL PROCESSING, 2010, 20 (03) : 887 - 899
  • [28] Joint Angle and Frequency Estimation Using Multiple-Delay Output Based on ESPRIT
    Wang Xudong
    EURASIP Journal on Advances in Signal Processing, 2010
  • [29] Functional calibration procedure for 3D knee joint angle description using inertial sensors
    Favre, J.
    Aissaoui, R.
    Jolles, B. M.
    de Guise, J. A.
    Aminian, K.
    JOURNAL OF BIOMECHANICS, 2009, 42 (14) : 2330 - 2335
  • [30] sEMG-based upper limb motion recognition using improved sparrow search algorithm
    Chen, Peng
    Wang, Hongbo
    Yan, Hao
    Du, Jiazheng
    Ning, Yuansheng
    Wei, Jian
    APPLIED INTELLIGENCE, 2023, 53 (07) : 7677 - 7696