Feasibility of Automated Gonioscopy Imaging in Clinical Practice

被引:3
|
作者
Barbour-Hastie, Catriona [1 ,2 ]
Deol, Sundeep S. [1 ,2 ]
Peroni, Andrea [3 ]
Gillan, Stewart [4 ]
Trucco, Emanuele [3 ]
Tatham, Andrew J. [1 ,2 ,5 ]
机构
[1] Univ Edinburgh, NHS Lothian & Ctr Clin Brain Sci, Princess Alexandra Eye Pavil, Edinburgh, Scotland
[2] Univ Edinburgh, Edinburgh, Scotland
[3] Univ Dundee, Sch Sci & Engn, Dundee, Scotland
[4] NHS Tayside, Ninewells Hosp, Dept Ophthalmol, Dundee, Scotland
[5] Univ Edinburgh, Dept Ophthalmol, Princess Alexandra Eye Pavil, Chalmers St, Edinburgh EH3 9HA, Scotland
关键词
Gonioscopy; angle closure; glaucoma; imaging; diagnosis; GLAUCOMA;
D O I
10.1097/IJG.0000000000002162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis:Automated gonioscopy provided good-quality images of the anterior chamber angle. There was a short learning curve for operators, and the examination was well tolerated by patients. Patients expressed a preference for automated gonioscopy compared with traditional gonioscopy. Purpose:The purpose of this study was to assess the feasibility of using a desktop automated gonioscopy camera in glaucoma clinics by examining patient tolerability, ease of use, and image quality and comparing patient preference compared with traditional gonioscopy. Patients and Methods:A prospective study was conducted in a university hospital clinic. Traditional gonioscopy was performed followed by imaging of the iridocorneal angle (ICA) using the Nidek GS-1 camera by 2 glaucoma specialists. Participants were asked to rate the comfort of automated gonioscopy and which method they preferred. The clinicians graded the ease of acquisition for each patient, and the image quality was reviewed by a grader. Results:Forty-three eyes of 25 participants were included. Sixty-eight percent of participants viewed automated gonioscopy as "extremely comfortable," and the remainder reported it "comfortable". Forty percent preferred automated gonioscopy compared with traditional gonioscopy, while 52% were equivocal. Clinicians scored 32% of participants as "somewhat difficult" to the image. In 46% of eyes, good-quality photographs were obtained for 360 degrees of the ICA. Only 1 eye had no parts of the ICA clearly visible. Seventy-four percent of eyes had at least half of the ICA clearly visible in all 4 quadrants. Conclusion:Automated gonioscopy provided good-quality images of the ICA for most patients. It was often not possible to image the entire 360 degrees at the first attempt, but the examination was comfortable for patients, and only 8% preferred traditional gonioscopy to the automated photographic examination.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [41] Adnexal Mass Imaging: Contemporary Guidelines for Clinical Practice
    Roseland, Molly E.
    Maturen, Katherine E.
    Shampain, Kimberly L.
    Wasnik, Ashish P.
    Stein, Erica B.
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2023, 61 (04) : 671 - 685
  • [42] What future for in vivo photon imaging in clinical practice?
    Laplace-Builhe, Corinne
    Abbaci, Muriel
    ONCOLOGIE, 2010, 12 (03) : 202 - 207
  • [43] Dual Scheimpflug imaging as a screening method for occludable angles-a comparison with gonioscopy
    Natália Maes Bessa
    Rebeca de Azevedo Souza
    Marcony R.Santhiago
    Haroldo Vieira Moraes Jr
    Beatriz Fiuza Gomes
    International Journal of Ophthalmology, 2019, (02) : 241 - 245
  • [44] Clinical analysis of supraciliary effusion development following gonioscopy-assisted transluminal trabeculotomy surgery for pseudoexfoliation glaucoma
    Gunay, Murat
    Uzun, Burak
    Turk, Adem
    Kose, Busra
    Uzlu, Dilek
    ACTA OPHTHALMOLOGICA, 2024,
  • [45] Iridocorneal angle assessment of companion rabbits using gonioscopy, spectral-domain optical coherence tomography (Optovue iVue®), high-resolution ultrasound, and Pentacam HR imaging
    Li Puma, Margaret C.
    Freeman, Kate S.
    Cleymaet, Allison M.
    Pederson, Samantha L.
    Crawford, Amanda C.
    Dinger, Shelby C.
    Li Puma, Lance C.
    Johnston, Matthew S.
    VETERINARY OPHTHALMOLOGY, 2019, 22 (06) : 834 - 841
  • [46] Mycetoma imaging: the best practice
    Bahar, Mustafa Elnour
    Bakheet, Osama E. L. Hadi
    Fahal, Ahmed Hassan
    TRANSACTIONS OF THE ROYAL SOCIETY OF TROPICAL MEDICINE AND HYGIENE, 2021, 115 (04) : 387 - 396
  • [47] Indications, advantages and limitations of perinatal postmortem imaging in clinical practice
    Arthurs, Owen J.
    Taylor, Andrew M.
    Sebire, Neil J.
    PEDIATRIC RADIOLOGY, 2015, 45 (04) : 491 - 500
  • [48] The evolution of articular cartilage imaging and its impact on clinical practice
    Carl S. Winalski
    Prabhakar Rajiah
    Skeletal Radiology, 2011, 40 : 1197 - 1222
  • [49] The Pursuit of Value in Musculoskeletal Imaging: Policy and Clinical Practice Intersect
    Harkey, Paul
    Duszak, Richard, Jr.
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2017, 21 (01) : 3 - 8
  • [50] IMAGING OF AUTOIMMUNE ENCEPHALITIS - RELEVANCE FOR CLINICAL PRACTICE AND HIPPOCAMPAL FUNCTION
    Heine, J.
    Pruess, H.
    Bartsch, T.
    Ploner, C. J.
    Paul, F.
    Finke, C.
    NEUROSCIENCE, 2015, 309 : 68 - 83