Feasibility of Automated Gonioscopy Imaging in Clinical Practice

被引:3
|
作者
Barbour-Hastie, Catriona [1 ,2 ]
Deol, Sundeep S. [1 ,2 ]
Peroni, Andrea [3 ]
Gillan, Stewart [4 ]
Trucco, Emanuele [3 ]
Tatham, Andrew J. [1 ,2 ,5 ]
机构
[1] Univ Edinburgh, NHS Lothian & Ctr Clin Brain Sci, Princess Alexandra Eye Pavil, Edinburgh, Scotland
[2] Univ Edinburgh, Edinburgh, Scotland
[3] Univ Dundee, Sch Sci & Engn, Dundee, Scotland
[4] NHS Tayside, Ninewells Hosp, Dept Ophthalmol, Dundee, Scotland
[5] Univ Edinburgh, Dept Ophthalmol, Princess Alexandra Eye Pavil, Chalmers St, Edinburgh EH3 9HA, Scotland
关键词
Gonioscopy; angle closure; glaucoma; imaging; diagnosis; GLAUCOMA;
D O I
10.1097/IJG.0000000000002162
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Precis:Automated gonioscopy provided good-quality images of the anterior chamber angle. There was a short learning curve for operators, and the examination was well tolerated by patients. Patients expressed a preference for automated gonioscopy compared with traditional gonioscopy. Purpose:The purpose of this study was to assess the feasibility of using a desktop automated gonioscopy camera in glaucoma clinics by examining patient tolerability, ease of use, and image quality and comparing patient preference compared with traditional gonioscopy. Patients and Methods:A prospective study was conducted in a university hospital clinic. Traditional gonioscopy was performed followed by imaging of the iridocorneal angle (ICA) using the Nidek GS-1 camera by 2 glaucoma specialists. Participants were asked to rate the comfort of automated gonioscopy and which method they preferred. The clinicians graded the ease of acquisition for each patient, and the image quality was reviewed by a grader. Results:Forty-three eyes of 25 participants were included. Sixty-eight percent of participants viewed automated gonioscopy as "extremely comfortable," and the remainder reported it "comfortable". Forty percent preferred automated gonioscopy compared with traditional gonioscopy, while 52% were equivocal. Clinicians scored 32% of participants as "somewhat difficult" to the image. In 46% of eyes, good-quality photographs were obtained for 360 degrees of the ICA. Only 1 eye had no parts of the ICA clearly visible. Seventy-four percent of eyes had at least half of the ICA clearly visible in all 4 quadrants. Conclusion:Automated gonioscopy provided good-quality images of the ICA for most patients. It was often not possible to image the entire 360 degrees at the first attempt, but the examination was comfortable for patients, and only 8% preferred traditional gonioscopy to the automated photographic examination.
引用
收藏
页码:159 / 164
页数:6
相关论文
共 50 条
  • [21] Bridging gaps in ophthalmology residency programs: the link between practice, training and confidence in ocular examination and gonioscopy for diagnosing glaucoma, a blinding disease
    Tempelhof, Ortal Fogel
    Mezad-Koursh, Daphna
    Hilely, Assaf
    Gaton, Dan
    Kurtz, Shimon
    BMC MEDICAL EDUCATION, 2024, 24 (01)
  • [22] Amyloid imaging for dementia in clinical practice
    John T. O’Brien
    Karl Herholz
    BMC Medicine, 13
  • [23] Molecular Breast Imaging in Clinical Practice
    Dibble, Elizabeth H.
    Hunt, Katie N.
    Ehman, Eric C.
    O'Connor, Michael K.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2020, 215 (02) : 277 - 284
  • [24] MR imaging of the prostate in clinical practice
    Yousef Mazaheri
    Amita Shukla-Dave
    Ada Muellner
    Hedvig Hricak
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2008, 21
  • [25] MR imaging of the prostate in clinical practice
    Mazaheri, Yousef
    Shukla-Dave, Amita
    Muellner, Ada
    Hricak, Hedvig
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2008, 21 (06) : 379 - 392
  • [26] Novel automated hematology parameters in clinical pediatric practice
    Rastogi P.
    Bhatia P.
    Varma N.
    Indian Pediatrics, 2017, 54 (5) : 395 - 401
  • [27] Limitations of an automated embolism segmentation method in clinical practice
    Wang, Ruifeng
    Yu, Nan
    Zhou, Sheng
    Dong, Fuwen
    Wang, Jun
    Yin, Nan
    Bai, Lu
    Shen, Cong
    Guo, Youmin
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2018, 26 (04) : 667 - 680
  • [28] Novel Automated Hematology Parameters in Clinical Pediatric Practice
    Rastogi, Pulkit
    Bhatia, Prateek
    Varma, Neelam
    INDIAN PEDIATRICS, 2017, 54 (05) : 395 - 401
  • [29] Performance of imaging devices versus optic disc and fiber layer photography in a clinical practice guideline for glaucoma diagnosis
    Guerri, Noemi
    Polo, Vicente
    Larrosa, Jose M.
    Ferreras, Antonio
    Fuertes, Isabel
    Pablo, Luis E.
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (04) : 554 - 562
  • [30] Accuracy of imaging in discriminating complicated from uncomplicated appendicitis in daily clinical practice
    Bolmers, Matthijs D. M.
    Bom, Wouter J.
    Scheijmans, Jochem C. G.
    van Geloven, Anna A. W.
    Boermeester, Marja. A.
    Bemelman, Willem A.
    van Rossem, Charles. C.
    INTERNATIONAL JOURNAL OF COLORECTAL DISEASE, 2022, 37 (06) : 1385 - 1391