Novel 3D printed single electrode-based portable and miniaturized electrochemiluminescence platform to detect lactate from human serum

被引:7
作者
Bhaiyya, Manish [1 ]
Rewatkar, Prakash [1 ]
Pattnaik, Prasant Kumar [1 ]
Goel, Sanket [1 ]
机构
[1] Birla Inst Technol & Sci BITS Pilani, Dept Elect & Elect Engn, Microfluid & Nanoelect Lab, MEMS, Hyderabad Campus, Hyderabad 500078, India
关键词
3D printer; microfluidics; single electrode; electrochemiluminescence; point of care testing; conductive filaments; lactate sensing; BIOSENSOR; SYSTEM;
D O I
10.1088/1361-6439/acac3e
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In low- and middle-income countries, three-dimensional printing (3DP) microfluidic devices have demonstrated their potential to be employed in a variety of point-of-care testing applications. This is due to the fact that they offer many advantages over traditional fabrication techniques, like rapid response, easy integration with miniaturized systems, requiring less sample volume, fast prototyping and cost-effectiveness. To the best of our knowledge for the first time, a novel 3D printed single electrode based electrochemiluminescence (3DP-SE-ECL) sensing device was fabricated and utilized to detect various analytes. To fabricate the 3DP-SE-ECL device, the commercially available conductive filaments, like graphene and carbon, were used and an in-depth analysis was performed by sensing H2O2. Furthermore, in order to validate the analytical performance, the best conductive material (graphene filament) was chosen to realize the optimized 3DP-SE-ECL platform, which was validated for lactate sensing. To detect the electrochemiluminescence signal, two approaches were used, first using photomultiplier tube (PMT) and the second by using a smartphone. The lactate concentration was changed from 100 to 7000 mu M and a linear range was obtained from 100 to 1000 mu M using both PMT and smartphone. Further, the limit of detection was measured to be 6.47 mu M and 5.33 mu M by smartphone and PMT respectively. To validate the practical usability of 3DP-SE-ECL, real sample analysis of lactate with standard spiking method was performed with excellent recovery rate. Overall, the fabricated 3D-SE-ECL device has the possibilities to be used for a variety of applications, including biomedical and environmental monitoring.
引用
收藏
页数:11
相关论文
共 39 条
  • [31] Rusling James F., 2016, BIOSTEC 2016. 9th International Joint Conference on Biomedical Engineering Systems and Technologies. Proceedings: Biodevices, P17
  • [32] Relationship between Lactate Concentrations in Active Muscle Sweat and Whole Blood
    Sakharov, D. A.
    Shkurnikov, M. U.
    Vagin, M. Yu.
    Yashina, E. I.
    Karyakin, A. A.
    Tonevitsky, A. G.
    [J]. BULLETIN OF EXPERIMENTAL BIOLOGY AND MEDICINE, 2010, 150 (01) : 83 - 85
  • [33] ELECTROCHEMILUMINESCENCE OF HYDROGEN-PEROXIDE LUMINOL AT A CARBON ELECTRODE
    SAKURA, S
    [J]. ANALYTICA CHIMICA ACTA, 1992, 262 (01) : 49 - 57
  • [34] Advances in Nanotechnology and Microfluidics for Human Papillomavirus Diagnostics
    Tasoglu, Savas
    Tekin, H. Cumhur
    Inci, Fatih
    Knowlton, Stephanie
    Wang, ShuQi
    Wang-Johanning, Feng
    Johanning, Gary
    Colevas, Dimitrios
    Demirci, Utkan
    [J]. PROCEEDINGS OF THE IEEE, 2015, 103 (02) : 161 - 178
  • [35] NORMAL-RANGE BLOOD LACTATE CONCENTRATION IN SEPTIC SHOCK IS PROGNOSTIC AND PREDICTIVE
    Wacharasint, Petch
    Nakada, Taka-aki
    Boyd, John H.
    Russell, James A.
    Walley, Keith R.
    [J]. SHOCK, 2012, 38 (01): : 4 - 10
  • [36] A Simple and Sensitive Paper-Based Bipolar Electrochemiluminescence Biosensor for Detection of Oxidase-Substrate Biomarkers in Serum
    Wang, Dan
    Liu, Cuiling
    Liang, Yi
    Su, Yan
    Shang, Qiuping
    Zhang, Chunsun
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (09) : B361 - B369
  • [37] Electrochemiluminescence bipolar electrode array for the multiplexed detection of glucose, lactate and choline based on a versatile enzymatic approach
    Xiao, Yi
    Xu, Linru
    Qi, Lian-Wen
    [J]. TALANTA, 2017, 165 : 577 - 583
  • [38] An electrochemiluminescence cloth-based biosensor with smartphone-based imaging for detection of lactate in saliva
    Yao, Yong
    Li, Huijie
    Wang, Dan
    Liu, Cuiling
    Zhang, Chunsun
    [J]. ANALYST, 2017, 142 (19) : 3715 - 3724
  • [39] A novel biosensor array with a wheel-like pattern for glucose, lactate and choline based on electrochemiluminescence imaging
    Zhou, Zhenyu
    Xu, Linru
    Wu, Suozhu
    Su, Bin
    [J]. ANALYST, 2014, 139 (19) : 4934 - 4939