Investigation of the effect of magnetic field on the PEC and exergy of heat exchanger filled with two-phase hybrid nanofluid, equipped with an edged twisted tape

被引:9
|
作者
El-Shafay, A. S. [1 ,2 ]
Mohamed, Abdeliazim Mustafa [3 ,4 ]
Agbulut, Umit [5 ]
Gad, M. S. [6 ]
机构
[1] Prince Sattam Bin Abdulaziz Univ, Coll Engn Al Kharj, Dept Mech Engn, Al Kharj 11942, Saudi Arabia
[2] Mansoura Univ, Fac Engn, Mech Power Engn Dept, Mansoura 35516, Egypt
[3] Kharj Prince Sattam Bin Abdulaziz Univ, Coll Engn Al, Dept Civil Engn, Al Kharj 11942, Saudi Arabia
[4] Bayan Univ, Bldg & Construct Technol Dept, Khartoum 210, Sudan
[5] Duzce Univ, Fac Engn, Mech Engn, TR-81620 Duzce, Turkiye
[6] Fayoum Univ, Fac Engn, Mech Engn Dept, Faiyum, Egypt
关键词
Heat exchanger; Twisted tape; Two-phase model; Hybrid nanofluid; Exergy efficiency; Magnetic field; ENTROPY GENERATION ANALYSIS; TRANSFER ENHANCEMENT; TUBE; PERFORMANCE; FLOW;
D O I
10.1016/j.enganabound.2022.12.025
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, the effect of using hybrid nanofluid and helical twisted tape (HTT) on the exergy efficiency and thermo-hydraulic performance of a heat exchanger is investigated numerically using the finite volume method (FVM). Also, Solidworks is used to sketch the geometry. The study is carried out by assuming the steady state flow using the pressure-based solver. Simulations of Cu-ZnO/water hybrid nanofluids are based on the mixture model. The Reynolds number (Re) changes from 10,000 to 40,000, volume fraction (phi) vary from 1 to 5%, and pitch ratio (PR) is of 1, 2, 3, and 4. The results demonstrate that the average Nusselt number (Nuav) and thermal performance of the heat exchanger are enhanced with Re and phi. At phi = 5% and Re = 40,000, placing a HTT with a PR of 4 causes the pressure drop (Delta P) to enhance by 180.97% In comparison with a collector without a solar panel a turbulator. In addition, in the heat exchanger with a HTT with a PR of 4 and phi = 5%, the exergy efficiency is increased by 38.89% as Re is enhanced from 10,000 to 40,000. The use of a magnetic field causes the PEC in the heat exchanger to become greater than 1 in all cases. Also, the maximum exergy efficiency occurs when a magnetic field is applied at Re = 20,000 and a Hartmann number (Ha) of 150.
引用
收藏
页码:153 / 164
页数:12
相关论文
共 50 条
  • [1] Two-phase simulation of a shell and tube heat exchanger filled with hybrid nanofluid
    Alqarni, M. M.
    Ibrahim, Muhammaad
    Assiri, Taghreed A.
    Saeed, Tareq
    Mousa, Abd Allah A.
    Ali, Vakkar
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 146 : 80 - 88
  • [2] Investigation of Overlapped Twisted Tapes Inserted in a Double-Pipe Heat Exchanger Using Two-Phase Nanofluid
    Ghalambaz, Mehdi
    Arasteh, Hossein
    Mashayekhi, Ramin
    Keshmiri, Amir
    Talebizadehsardari, Pouyan
    Yaici, Wahiba
    NANOMATERIALS, 2020, 10 (09) : 1 - 17
  • [3] Impact of vortex generator, magnetic field, and magnetic two-phase hybrid nanofluid on the performance of a dual-tube heat exchanger: Hydrodynamic and exergy analyses
    Liu, Xiaomei
    Le, Binh Nguyen
    Karimipour, Aliakbar
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 157 : 471 - 482
  • [4] Numerical simulation of dual-tube heat exchanger equipped with an innovative turbulator containing two-phase hybrid nanofluid: Hydrodynamic and exergy analysis
    Negeed, El-Sayed R.
    Alhazmy, Majed
    Abulkhair, Hani
    Attar, H. M.
    Hedia, H. S.
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 155 : 1059 - 1068
  • [5] Numerical investigation of the simultaneous effect of twisted tape and nanofluid hybrid in shell and spiral tube heat exchanger with a special design
    Karouei, Seyed Hossein Hashemi
    Jasim, Dheyaa J.
    Fares, Mohammad N.
    Sabri, Laith S.
    Al-Shati, Ahmed Salah
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 64
  • [6] The effects of tape insert material on the flow and heat transfer in a nanofluid-based double tube heat exchanger: Two-phase mixture model
    Karimi, Ali
    Al-Rashed, Abdullah A. A. A.
    Afrand, Masoud
    Mahian, Omid
    Wongwises, Somchai
    Shahsavar, Amin
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2019, 156 : 397 - 409
  • [7] Numerical solution for optimization of curved turbulator geometry in a double-pipe heat exchanger containing two-phase Cu-GO/Therminol VP-1 hybrid nanofluid to achieve maximum exergy efficiency
    Khdair, Adnan I.
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 155 : 803 - 813
  • [8] Improving the thermal efficiency of parabolic trough collector equipped with combined turbulator containing two-phase magnetic hybrid nanofluid
    Ghanbari, Gholamhossein
    Marzban, Ali
    Yousefzadeh, Shahrouz
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 155 : 565 - 583
  • [9] Multiphase numerical simulation of exergy loss and thermo-hydraulic behavior with environmental cosiderations of a hybrid nanofluid in a shell-and-tube heat exchanger with twisted tape
    Wang, Dan
    Ali, Masood Ashraf
    Sharma, Kamal
    Almojil, Sattam Fahad
    Alizadeh, As'ad
    Alali, Abdulrhman Fahmi
    Almohana, Abdulaziz Ibrahim
    ENGINEERING ANALYSIS WITH BOUNDARY ELEMENTS, 2023, 147 : 1 - 10
  • [10] Effect of nanofluid concentration on two-phase thermosyphon heat exchanger performance
    Cieslinski, Janusz T.
    ARCHIVES OF THERMODYNAMICS, 2016, 37 (02) : 23 - 40