Quantifying microbial robustness in dynamic environments using microfluidic single-cell cultivation

被引:1
|
作者
Bloebaum, Luisa [1 ,2 ]
Pianale, Luca Torello [3 ]
Olsson, Lisbeth [3 ]
Gruenberger, Alexander [1 ,4 ]
机构
[1] Bielefeld Univ, Tech Fac, Multiscale Bioengn, Bielefeld, Germany
[2] Bielefeld Univ, CeBiTec, Bielefeld, Germany
[3] Chalmers Univ Technol, Dept Life Sci, Ind Biotechnol Div, Gothenburg, Sweden
[4] Karlsruhe Inst Technol, Inst Proc Engn Life Sci, Microsyst Bioproc Engn, Karlsruhe, Germany
关键词
Saccharomyces cerevisiae; Population heterogeneity; Dynamic environments; Scale-down; Biosensors; Live-cell imaging; Microfluidic single-cell cultivation; Nutrient oscillation; SACCHAROMYCES-CEREVISIAE; SCALE-UP; STRESS; PLATFORM; TOOLS; ACID;
D O I
10.1186/s12934-024-02318-z
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
BackgroundMicroorganisms must respond to changes in their environment. Analysing the robustness of functions (i.e. performance stability) to such dynamic perturbations is of great interest in both laboratory and industrial settings. Recently, a quantification method capable of assessing the robustness of various functions, such as specific growth rate or product yield, across different conditions, time frames, and populations has been developed for microorganisms grown in a 96-well plate. In micro-titer-plates, environmental change is slow and undefined. Dynamic microfluidic single-cell cultivation (dMSCC) enables the precise maintenance and manipulation of microenvironments, while tracking single cells over time using live-cell imaging. Here, we combined dMSCC and a robustness quantification method to a pipeline for assessing performance stability to changes occurring within seconds or minutes.ResultsSaccharomyces cerevisiae CEN.PK113-7D, harbouring a biosensor for intracellular ATP levels, was exposed to glucose feast-starvation cycles, with each condition lasting from 1.5 to 48 min over a 20 h period. A semi-automated image and data analysis pipeline was developed and applied to assess the performance and robustness of various functions at population, subpopulation, and single-cell resolution. We observed a decrease in specific growth rate but an increase in intracellular ATP levels with longer oscillation intervals. Cells subjected to 48 min oscillations exhibited the highest average ATP content, but the lowest stability over time and the highest heterogeneity within the population.ConclusionThe proposed pipeline enabled the investigation of function stability in dynamic environments, both over time and within populations. The strategy allows for parallelisation and automation, and is easily adaptable to new organisms, biosensors, cultivation conditions, and oscillation frequencies. Insights on the microbial response to changing environments will guide strain development and bioprocess optimisation.
引用
收藏
页数:20
相关论文
共 50 条
  • [21] Microfluidic single-cell cultivation chip with controllable immobilization and selective release of yeast cells
    Zhu, Zhen
    Frey, Olivier
    Ottoz, Diana Silvia
    Rudolf, Fabian
    Hierlemann, Andreas
    LAB ON A CHIP, 2012, 12 (05) : 906 - 915
  • [22] Author Correction: Dynamic single-cell phenotyping of immune cells using the microfluidic platform DropMap
    Yacine Bounab
    Klaus Eyer
    Sophie Dixneuf
    Magda Rybczynska
    Cécile Chauvel
    Maxime Mistretta
    Trang Tran
    Nathan Aymerich
    Guilhem Chenon
    Jean-François Llitjos
    Fabienne Venet
    Guillaume Monneret
    Iain A. Gillespie
    Pierre Cortez
    Virginie Moucadel
    Alexandre Pachot
    Alain Troesch
    Philippe Leissner
    Julien Textoris
    Jérôme Bibette
    Cyril Guyard
    Jean Baudry
    Andrew D. Griffiths
    Christophe Védrine
    Nature Protocols, 2021, 16 : 4108 - 4108
  • [23] Microbial single-cell analysis in picoliter-sized batch cultivation chambers
    Kaganovitch, Eugen
    Steurer, Xenia
    Dogan, Deniz
    Probst, Christopher
    Wiechert, Wolfgang
    Kohlheyer, Dietrich
    NEW BIOTECHNOLOGY, 2018, 47 : 50 - 59
  • [24] Measurement of single-cell adhesion strength using a microfluidic assay
    Kevin V. Christ
    Kyle B. Williamson
    Kristyn S. Masters
    Kevin T. Turner
    Biomedical Microdevices, 2010, 12 : 443 - 455
  • [25] Measurement of single-cell adhesion strength using a microfluidic assay
    Christ, Kevin V.
    Williamson, Kyle B.
    Masters, Kristyn S.
    Turner, Kevin T.
    BIOMEDICAL MICRODEVICES, 2010, 12 (03) : 443 - 455
  • [26] Microfluidic Cell Trapping for Single-Cell Analysis
    Deng, Bing
    Wang, Heyi
    Tan, Zhaoyi
    Quan, Yi
    MICROMACHINES, 2019, 10 (06)
  • [27] Microfluidic device for single-cell analysis
    Wheeler, AR
    Throndset, WR
    Whelan, RJ
    Leach, AM
    Zare, RN
    Liao, YH
    Farrell, K
    Manger, ID
    Daridon, A
    ANALYTICAL CHEMISTRY, 2003, 75 (14) : 3581 - 3586
  • [28] Single-cell Analysis with Microfluidic Devices
    Ou, Xiaowen
    Chen, Peng
    Idut, Bi-Feng
    ANALYTICAL SCIENCES, 2019, 35 (06) : 609 - 618
  • [29] Microfluidic Single-Cell Omics Analysis
    Xu, Xing
    Wang, Junxia
    Wu, Lingling
    Guo, Jingjing
    Song, Yanling
    Tian, Tian
    Wang, Wei
    Zhu, Zhi
    Yang, Chaoyong
    SMALL, 2020, 16 (09)
  • [30] Microfluidic microarray for single-cell analysis
    Rothbauer, Mario
    Schuller, Patrick
    Afkhami, Reza
    Wanzenboeck, Heinz D.
    Ertl, Peter
    Zirath, Helene
    ELEKTROTECHNIK UND INFORMATIONSTECHNIK, 2020, 137 (03): : 108 - 112