Biomechanical evaluation of a novel anterior transpedicular screw-plate system for anterior cervical corpectomy and fusion (ACCF): a finite element analysis

被引:1
|
作者
Huang, Shengbin [1 ,2 ]
Ling, Qinjie [3 ]
Lin, Xinxin [2 ]
Qin, Hao [2 ]
Luo, Xiang [2 ]
Huang, Wenhua [1 ,4 ]
机构
[1] Guangxi Med Univ, Sch Basic Med Sci, Dept Human Anat, Nanning, Guangxi, Peoples R China
[2] Guangxi Med Univ, Dept Cardiol, Affiliated Hosp 8, Guigang, Peoples R China
[3] Guangzhou Med Univ, Dept Spinal Surg, Affiliated Hosp 1, Guangzhou, Guangdong, Peoples R China
[4] Southern Med Univ, Guangdong Engn Res Ctr Translat Med 3D Printing Ap, Guangdong Prov Key Lab Med Biomech, Sch Basic Med Sci,Natl Key Discipline Human Anat, Guangzhou, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
cervical spine; anterior pedicle screw; anterior surgery; corpectomy; reconstruction; biomechanics; finite element analysis; PULL-OUT STRENGTH; PEDICLE-SCREW; FIXATION; SPINE; RECONSTRUCTION; STABILITY; 4-LEVEL; INJURY; LOAD;
D O I
10.3389/fbioe.2023.1260204
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Background and objective: Cervical fusion with vertebral body screw (VBS)-plate systems frequently results in limited biomechanical stability. To address this issue, anterior transpedicular screw (ATPS) fixation has been developed and applied preliminarily to multilevel spinal fusion, osteoporosis, and three-column injury of the cervical spine. This study aimed to compare the biomechanical differences between unilateral ATPS (UATPS), bilateral ATPS (BATPS), and VBS fixation using finite element analysis.Materials and methods: A C6 corpectomy model was performed and a titanium mesh cage (TMC) and bone were implanted, followed by implantation of a novel ATPS-plate system into C5 and C7 to simulate internal fixation with UATPS, BATPS, and VBS. Internal fixation with UATPS comprises ipsilateral transpedicular screw-contralateral vertebral body screw (ITPS-CVBS) and cross transpedicular screw-vertebral body screw (CTPS-VBS) fixations. Mobility, the maximal von Mises stress on TMC, the stress distribution and maximal von Mises stress on the screws, and the maximum displacement of the screw were compared between the four groups.Results: Compared with the original model, each group had a reduced range of motion (ROM) under six loads. After ACCF, the stress was predominantly concentrated at two-thirds of the length from the tail of the screw, and it was higher on ATPS than on VBS. The stress of the ATPS from the cranial part was higher than that of the caudal part. The similar effect happened on VBS. The screw stress cloud maps did not show any red areas reflective of a concentration of the stress on VBS. Compared with VBS, ATPS can bear a greater stress from cervical spine movements, thus reducing the stress on TMC. The maximal von Mises stress was the lowest with bilateral transpedicular TMC and increased with cross ATPS and with ipsilateral ATPS. ITPS-CVBS, CTPS-VBS, and BATPS exhibited a reduction of 2.3%-22.1%, 11.9%-2.7%, and 37.9%-64.1% in the maximum displacement of screws, respectively, compared with that of VBS.Conclusion: In FEA, the comprehensive stability ranked highest for BATPS, followed by CTPS-VBS and ITPS-CVBS, with VBS demonstrating the lowest stability. Notably, utilizing ATPS for fixation has the potential to reduce the occurrence of internal fixation device loosening after ACCF when compared to VBS.
引用
收藏
页数:11
相关论文
共 50 条
  • [31] Anterior Controllable Antedisplacement Fusion (ACAF) for Severe Cervical Ossification of the Posterior Longitudinal Ligament: Comparison with Anterior Cervical Corpectomy with Fusion (ACCF)
    Yang, Haisong
    Sun, Jingchuan
    Shi, Jiangang
    Shi, Guodong
    Guo, Yongfei
    Yang, Yong
    WORLD NEUROSURGERY, 2018, 115 : E428 - E436
  • [32] Finite element analysis of anterior cervical spine interbody fusion
    Kumaresan, S
    Yoganandan, N
    Pintar, FA
    BIO-MEDICAL MATERIALS AND ENGINEERING, 1997, 7 (04) : 221 - 230
  • [33] Biomechanical Analysis of Differential Pull-Out Strengths of Bone Screws Using Cervical Anterior Transpedicular Technique in Normal and Osteoporotic Cervical Cadaveric Spines
    Wu, Changfu
    Chen, Chun
    Wu, Weidong
    Zhao, Weidong
    Sun, Peidong
    Fan, Jihong
    Bi, Zhenyu
    Zhang, Jinyuan
    Ouyang, Jun
    SPINE, 2015, 40 (01) : E1 - E8
  • [34] Biomechanical comparison of anterior cervical spine instrumentation techniques with and without supplemental posterior fusion after different corpectomy and discectomy combinations
    Setzer, Matthias
    Eleraky, Mohamed
    Johnson, Wesley M.
    Aghayev, Kamran
    Tran, Nam D.
    Vrionis, Frank D.
    JOURNAL OF NEUROSURGERY-SPINE, 2012, 16 (06) : 579 - 584
  • [35] The effects of titanium mesh cage size on the biomechanical responses of cervical spine after anterior cervical corpectomy and fusion: A finite element study
    Zhou, Enze
    Huang, Huiwen
    Zhao, Yanbin
    Wang, Lizhen
    Fan, Yubo
    CLINICAL BIOMECHANICS, 2022, 91
  • [36] A spontaneous anterior fusion of lumbar spine after posterolateral lumbar fusion with pedicle screw-plate system
    Kraiwattanapong, Chaiwat
    Chandrsawang, Issara
    Keorochana, Gun
    Rajinda, Panupol
    Chanplakorn, Pongsthorn
    Leelapattana, Pittavat
    Udomsubpayakul, Umaporn
    Lertudomphonwanit, Thamrong
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [37] Cage-screw and anterior plating combination reduces the risk of micromotion and subsidence in multilevel anterior cervical discectomy and fusion-a finite element study
    Lin, Maohua
    Shapiro, Stephen Z.
    Doulgeris, James
    Engeberg, Erik D.
    Tsai, Chi-Tay
    Vrionis, Frank D.
    SPINE JOURNAL, 2021, 21 (05) : 874 - 882
  • [38] Biomechanical assessment of anterior plate system, bilateral pedicle screw and transdiscal screw system for high-grade spondylolisthesis: a finite element study
    Dhar, Utpal K.
    Sultan, Hadi
    Aghayev, Kamran
    Tsai, Chi-Tay
    Vrionis, Frank D.
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2024, 12
  • [39] Biomechanical effects on the intermediate segment of noncontiguous hybrid surgery with cervical disc arthroplasty and anterior cervical discectomy and fusion: a finite element analysis
    Wu, Ting-kui
    Meng, Yang
    Liu, Hao
    Wang, Bei-yu
    Hong, Ying
    Rong, Xin
    Ding, Chen
    Chen, Hua
    SPINE JOURNAL, 2019, 19 (07) : 1254 - 1263
  • [40] Anterior transpedicular screws in conjunction with plate fixation and fusion for the treatment of subaxial cervical spine diseases
    Jie Li
    Liujun Zhao
    Wangmi Liu
    Weihu Ma
    Rongming Xu
    Wei-yu Jiang
    Yongjie Gu
    Liangjie Lu
    Liang Yu
    Feng Qi
    European Spine Journal, 2015, 24 : 1681 - 1690