Biaxial ultrasound driving technique for small animal blood-brain barrier opening

被引:5
作者
Pellow, Carly [1 ,2 ]
Li, Siyun [1 ]
Delgado, Sagid [1 ]
Pike, G. Bruce [1 ,2 ,3 ]
Curiel, Laura [2 ,4 ]
Pichardo, Samuel [1 ,2 ,3 ]
机构
[1] Univ Calgary, Cumming Sch Med, Dept Radiol, Calgary, AB, Canada
[2] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[3] Univ Calgary, Cumming Sch Med, Dept Clin Neurosci, Calgary, AB, Canada
[4] Univ Calgary, Schulich Sch Engn, Dept Biomed Engn, Calgary, AB, Canada
基金
加拿大创新基金会; 加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
biaxial transducer; blood-brain barrier; magnetic resonance imaging; microbubble; transcranial focused ultrasound; FOCUSED-ULTRASOUND; DRUG-DELIVERY; DISRUPTION; MICROBUBBLES; PERMEABILITY; ATTENUATION; DEFINITY; SAFETY; SKULL;
D O I
10.1088/1361-6560/acf2e3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biaxial driving can more efficiently convert electrical power to forward acoustic power in piezoelectric materials, and the interaction between the orthogonal electric fields can produce a combination of extensional and shear deformations as a function of the phase difference between them to allow dynamic steering of the beam with a single-element. In this study, we demonstrate for the first time the application of a single-element biaxially driven ring transducer in vivo for blood-brain barrier opening in mice, and compare it to that achieved with a conventional single-element highly focused (F# = 0.7) spherical transducer operating at a similar frequency. Transcranial focused ultrasound (0.45 MPa, 10 ms pulse length, 1 Hz repetition frequency, 30 s duration) was applied bilaterally to mice with a 40 & mu;l/kg bolus of DefinityTM microbubbles, employing either a single-element biaxial ring (1.482 MHz, 10 mm inner diameter, 13.75 mm outer diameter) or spherical (1.5 MHz, 35 mm diameter, F# = 0.7; RK50, FUS Instruments) transducer on each side. Follow-up MRI scans (T1 pre- and post- 0.2 mmol/kg Gd injection, T2) were acquired to assess blood-brain barrier opening volume and potential damage. Compared to blood-brain barrier opening achieved with a conventional single-element spherical focused transducer, the opening volume achieved with a single-element biaxial ring transducer was 35% smaller (p = 0.002) with a device of a ring diameter of 40% the aperture size. Axial refocusing was further demonstrated with the single-element biaxial ring transducer, yielding a 1.63 mm deeper, five-fold larger opening volume (p = 0.048) relative to its small-focus mode. The biaxial ring transducer achieved a more localized opening compared to the spherical focused transducer under the same parameters, and further enabled dynamic axial refocusing with a single-element transducer with a smaller fabrication footprint.
引用
收藏
页数:12
相关论文
共 50 条
[21]   LONGITUDINAL MOTOR AND BEHAVIORAL ASSESSMENT OF BLOOD-BRAIN BARRIER OPENING WITH TRANSCRANIAL FOCUSED ULTRASOUND [J].
Olumolade, Oluyemi O. ;
Wang, Shutao ;
Samiotaki, Gesthimani ;
Konofagou, Elisa E. .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2016, 42 (09) :2270-2282
[22]   Microbubble volume: A definitive dose parameter in blood-brain barrier opening by focused ultrasound [J].
Song, Kang-Ho ;
Fan, Alexander C. ;
Harvey, Brandon K. ;
Borden, Mark A. .
2019 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2019, :5-7
[23]   Characteristics of Focused Ultrasound Mediated Blood-Brain Barrier Opening in Magnetic Resonance Images [J].
Chang, Kyung Won ;
Hong, Seung Woo ;
Chang, Won Seok ;
Jung, Hyun Ho ;
Chang, Jin Woo .
JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2023, 66 (02) :172-182
[24]   Magnetic Enhancement of Stem Cell-Targeted Delivery into the Brain Following MR-Guided Focused Ultrasound for Opening the Blood-Brain Barrier [J].
Shen, Wei-Bin ;
Anastasiadis, Pavlos ;
Nguyen, Ben ;
Yarnell, Deborah ;
Yarowsky, Paul J. ;
Frenkel, Victor ;
Fishman, Paul S. .
CELL TRANSPLANTATION, 2017, 26 (07) :1235-1246
[25]   Acoustic Holograms for Bilateral Blood-Brain Barrier Opening in a Mouse Model [J].
Jimenez-Gambin, Sergio ;
Jimenez, Noe ;
Pouliopoulos, Antonios N. ;
Benlloch, Jose M. ;
Konofagou, Elisa E. ;
Camarena, Francisco .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2022, 69 (04) :1359-1368
[26]   Numerical simulation study on opening blood-brain barrier by ultrasonic cavitation [J].
Lei, Weirui ;
Chang, Shuai ;
Tian, Feng ;
Zou, Xiao ;
Hu, Jiwen ;
Qian, Shengyou .
ULTRASONICS SONOCHEMISTRY, 2024, 109
[27]   Safety and efficacy of focused ultrasound induced blood-brain barrier opening, an integrative review of animal and human studies [J].
Meng, Ying ;
Pople, Christopher B. ;
Lea-Banks, Harriet ;
Abrahao, Agessandro ;
Davidson, Benjamin ;
Suppiah, Suganth ;
Vecchio, Laura M. ;
Samuel, Nardin ;
Mahmud, Faiza ;
Hynynen, Kullervo ;
Hamani, Clement ;
Lipsman, Nir .
JOURNAL OF CONTROLLED RELEASE, 2019, 309 :25-36
[28]   Opening the Blood-Brain Barrier in the Substantia Nigra of Rat Brain with Focused Ultrasound and Microbubbles [J].
Rodriguez, J. A. ;
Reyes, C. J. ;
Gutierrez, M., I ;
Vera, A. ;
Martinez-Fong, D. ;
Negreira, C. ;
Leija, L. .
2019 GLOBAL MEDICAL ENGINEERING PHYSICS EXCHANGES/PAN AMERICAN HEALTH CARE EXCHANGES (GMEPE/PAHCE), 2019,
[29]   Ultrasound-Assisted Blood-Brain Barrier Opening Monitoring by Photoacoustic and Fluorescence Imaging Using Indocyanine Green [J].
Ador, Thomas ;
Fournie, Mylene ;
Rigollet, Sebastien ;
Counil, Claire ;
Stupar, Vasile ;
Barbier, Emmanuel L. ;
Pichon, Chantal ;
Delalande, Anthony .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2025, 51 (07) :1059-1069
[30]   Acoustic cavitation-based monitoring of the reversibility and permeability of ultrasound-induced blood-brain barrier opening [J].
Sun, Tao ;
Samiotaki, Gesthimani ;
Wang, Shutao ;
Acosta, Camilo ;
Chen, Cherry C. ;
Konofagou, Elisa E. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (23) :9079-9094