Biaxial ultrasound driving technique for small animal blood-brain barrier opening

被引:2
|
作者
Pellow, Carly [1 ,2 ]
Li, Siyun [1 ]
Delgado, Sagid [1 ]
Pike, G. Bruce [1 ,2 ,3 ]
Curiel, Laura [2 ,4 ]
Pichardo, Samuel [1 ,2 ,3 ]
机构
[1] Univ Calgary, Cumming Sch Med, Dept Radiol, Calgary, AB, Canada
[2] Univ Calgary, Hotchkiss Brain Inst, Calgary, AB, Canada
[3] Univ Calgary, Cumming Sch Med, Dept Clin Neurosci, Calgary, AB, Canada
[4] Univ Calgary, Schulich Sch Engn, Dept Biomed Engn, Calgary, AB, Canada
基金
加拿大创新基金会; 加拿大自然科学与工程研究理事会; 加拿大健康研究院;
关键词
biaxial transducer; blood-brain barrier; magnetic resonance imaging; microbubble; transcranial focused ultrasound; FOCUSED-ULTRASOUND; DRUG-DELIVERY; DISRUPTION; MICROBUBBLES; PERMEABILITY; ATTENUATION; DEFINITY; SAFETY; SKULL;
D O I
10.1088/1361-6560/acf2e3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Biaxial driving can more efficiently convert electrical power to forward acoustic power in piezoelectric materials, and the interaction between the orthogonal electric fields can produce a combination of extensional and shear deformations as a function of the phase difference between them to allow dynamic steering of the beam with a single-element. In this study, we demonstrate for the first time the application of a single-element biaxially driven ring transducer in vivo for blood-brain barrier opening in mice, and compare it to that achieved with a conventional single-element highly focused (F# = 0.7) spherical transducer operating at a similar frequency. Transcranial focused ultrasound (0.45 MPa, 10 ms pulse length, 1 Hz repetition frequency, 30 s duration) was applied bilaterally to mice with a 40 & mu;l/kg bolus of DefinityTM microbubbles, employing either a single-element biaxial ring (1.482 MHz, 10 mm inner diameter, 13.75 mm outer diameter) or spherical (1.5 MHz, 35 mm diameter, F# = 0.7; RK50, FUS Instruments) transducer on each side. Follow-up MRI scans (T1 pre- and post- 0.2 mmol/kg Gd injection, T2) were acquired to assess blood-brain barrier opening volume and potential damage. Compared to blood-brain barrier opening achieved with a conventional single-element spherical focused transducer, the opening volume achieved with a single-element biaxial ring transducer was 35% smaller (p = 0.002) with a device of a ring diameter of 40% the aperture size. Axial refocusing was further demonstrated with the single-element biaxial ring transducer, yielding a 1.63 mm deeper, five-fold larger opening volume (p = 0.048) relative to its small-focus mode. The biaxial ring transducer achieved a more localized opening compared to the spherical focused transducer under the same parameters, and further enabled dynamic axial refocusing with a single-element transducer with a smaller fabrication footprint.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Ultrasound-Induced Blood-Brain Barrier Opening
    Konofagou, Elisa E.
    Tung, Yao-Sheng
    Choi, James
    Deffieux, Thomas
    Baseri, Babak
    Vlachos, Fotios
    CURRENT PHARMACEUTICAL BIOTECHNOLOGY, 2012, 13 (07) : 1332 - 1345
  • [2] Magnetic Resonance Methods for Focused Ultrasound-Induced Blood-Brain Barrier Opening
    Conti, Allegra
    Kamimura, Hermes A. S.
    Novell, Anthony
    Duggento, Andrea
    Toschi, Nicola
    FRONTIERS IN PHYSICS, 2020, 8 (08):
  • [3] Small volume blood-brain barrier opening in macaques with a 1 MHz ultrasound phased array
    Manuel, Thomas J.
    Sigona, Michelle K.
    Phipps, M. Anthony
    Kusunose, Jiro
    Luo, Huiwen
    Yang, Pai-Feng
    Newton, Allen T.
    Gore, John C.
    Grissom, William
    Chen, Li Min
    Caskey, Charles F.
    JOURNAL OF CONTROLLED RELEASE, 2023, 363 : 707 - 720
  • [4] Optimization of the Ultrasound-Induced Blood-Brain Barrier Opening
    Konofagou, Elisa E.
    THERANOSTICS, 2012, 2 (12): : 1223 - 1237
  • [5] FEASIBILITY STUDY OF A CLINICAL BLOOD-BRAIN BARRIER OPENING ULTRASOUND SYSTEM
    Marquet, Fabrice
    Tung, Yao-Sheng
    Konofagou, Elisa E.
    NANO LIFE, 2010, 1 (3-4) : 309 - 322
  • [6] Blood-brain barrier opening with focused ultrasound in experimental models of Parkinson's disease
    Karakatsani, Maria Eleni
    Blesa, Javier
    Konofagou, Elisa Evgenia
    MOVEMENT DISORDERS, 2019, 34 (09) : 1252 - 1261
  • [7] The size of blood-brain barrier opening induced by focused ultrasound is dictated by the acoustic pressure
    Chen, Hong
    Konofagou, Elisa E.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2014, 34 (07) : 1197 - 1204
  • [8] LOCALIZED BLOOD-BRAIN BARRIER OPENING IN OVINE MODEL USING IMAGE-GUIDED TRANSCRANIAL FOCUSED ULTRASOUND
    Yoon, Kyungho
    Lee, Wonhye
    Chen, Emily
    Lee, Ji Eun
    Croce, Phillip
    Cammalleri, Amanda
    Foley, Lori
    Tsao, Allison L.
    Yoo, Seung-Schik
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (09) : 2391 - 2404
  • [9] Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening
    Ji, Robin
    Karakatsani, Maria E.
    Burgess, Mark
    Smith, Morgan
    Murillo, Maria F.
    Konofagou, Elisa E.
    JOURNAL OF CONTROLLED RELEASE, 2021, 337 : 458 - 471
  • [10] Opening of the blood-brain barrier with an unfocused ultrasound device in rabbits Laboratory investigation
    Beccaria, Kevin
    Canney, Michael
    Goldwirt, Lauriane
    Fernandez, Christine
    Adam, Clovis
    Piquet, Julie
    Autret, Gwennhael
    Clement, Olivier
    Lafon, Cyril
    Chapelon, Jean-Yves
    Carpentier, Alexandre
    JOURNAL OF NEUROSURGERY, 2013, 119 (04) : 887 - 898