Maximizing Annual Energy Yield in a Grid-Connected PV Solar Power Plant: Analysis of Seasonal Tilt Angle and Solar Tracking Strategies

被引:7
|
作者
Zaheb, Hameedullah [1 ,2 ]
Amiry, Habibullah [3 ]
Ahmadi, Mikaeel [1 ,4 ]
Fedayi, Habibullah [1 ]
Amiry, Sajida [2 ]
Yona, Atsushi [1 ]
机构
[1] Univ Ryukyus, Fac Engn, Dept Elect & Elect Engn, 1 Senbaru, Nishihara, Okinawa 9030213, Japan
[2] Kabul Univ, Fac Engn, Dept Energy Engn, Kabul 1006, Afghanistan
[3] Renewable Energy & Energy Efficiency Dept, Da Afghanistan Breshna Sherkat DABS, Kabul 1009, Afghanistan
[4] Univ Ryukyus, Cocreat Management Dept, Res Promot Unit, Nishihara, Okinawa 9030213, Japan
关键词
sustainable energy; sustainable development; energy yield; grid-connected PV; seasonal tilt; solar tracking; energy resilience; solar power generation; economic feasibility; SYSTEM; PERFORMANCE; OPTIMIZATION; TECHNOLOGY; REGION;
D O I
10.3390/su151411053
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Harnessing the abundant solar resources holds great potential for sustainable energy generation. This research paper delves into a comprehensive analysis of seasonal tilt and solar tracking strategy scenarios for a 15 MW grid-connected PV solar power plant situated in Kandahar province, Afghanistan. The study investigates the impact of fixed tilt, seasonal tilt, SAHST (single-axis horizontal solar tracking), and SAVST (single-axis vertical solar tracking) on energy yield, considering technical, economic, and environmental aspects. In the first scenario, a fixed tilt angle of 31 degrees was employed. The second scenario explored the use of seasonal tilt angles, with a summer tilt angle of 15 degrees and a winter tilt angle of 30 degrees. The third scenario analyzed SAHST. Finally, the fourth scenario focused on implementing SAVST. SAVST proved to be an exceptional solution, showcasing a remarkable increase in annual energy yield, and generating an additional 6680 MWh/year, 6336 MWh/year, and 5084 MWh/year compared to fixed, seasonal, and SAHST scenarios, respectively. As a result, surplus energy yielded an income of USD 554,440.00 per year compared to fixed tilt. However, the investment cost for the solar tracking system amounted to USD 1,451,932, accompanied by an annual operation and maintenance cost of 0.007 USD/W/year. The analysis revealed a promising payback period of 3 years, confirming the economic feasibility of this investment. The findings underscore the effectiveness of different strategies for optimizing solar power generation in the Kandahar region. Notably, the installation of SAVST emerged as an influential solution, significantly increasing power production. These research outcomes bear practical implications for solar tracking strategies for addressing the load challenges faced by Kandahar province and offer valuable insights for the operators and operation of solar power plants in similar regions.
引用
收藏
页数:20
相关论文
共 50 条
  • [31] Energy Quality Analysis of Grid-Connected Solar Inverter Topologies
    Ozli, Suheda
    Ciftci, Hazal
    Ayan, Onur
    Turkay, Belgin Emre
    2019 11TH INTERNATIONAL CONFERENCE ON ELECTRICAL AND ELECTRONICS ENGINEERING (ELECO 2019), 2019, : 997 - 1001
  • [32] An effective design method for grid-connected solar PV power plants for power supply reliability
    Konde, Arcell Lelo
    Kusaf, Mehmet
    Dagbasi, Mustafa
    ENERGY FOR SUSTAINABLE DEVELOPMENT, 2022, 70 : 301 - 313
  • [33] Modeling and Simulation of Grid Connected 1 MW Solar PV Power Plant
    Sahay, Kishan Bhushan
    Anand, Prabuddha
    Yadav, Vishal
    PROCEEDINGS OF THE 2018 INTERNATIONAL CONFERENCE AND UTILITY EXHIBITION ON GREEN ENERGY FOR SUSTAINABLE DEVELOPMENT (ICUE 2018), 2018,
  • [34] Application of Solar PV Grid-connected Power Generation System in Shanghai Rail Transit
    Jian, Li
    Min, Cui
    2018 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION (CICED), 2018, : 110 - 113
  • [35] The state of solar PV and performance analysis of different PV technologies grid-connected installations in Hungary
    Atsu, Divine
    Seres, Istvan
    Farkas, Istvan
    RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2021, 141
  • [36] Grid-Connected PV Inverter Test System for Solar Photovoltaic Power System Certification
    Liu, Yu-Jen
    Lan, Pei-Hsiu
    Lin, Hong-Hsun
    2014 IEEE PES GENERAL MEETING - CONFERENCE & EXPOSITION, 2014,
  • [37] Performance analysis of a 500-kWp grid-connected solar photovoltaic power plant in Kahramanmaras
    Yilmaz, Saban
    Ozcalik, Hasan Riza
    TURKISH JOURNAL OF ELECTRICAL ENGINEERING AND COMPUTER SCIENCES, 2015, 23 (06) : 1946 - 1957
  • [38] On Controlling Power Ramping and Output of Grid-Connected Rooftop Solar PV Using Battery Energy Storage System
    Saipet, Apichai
    Nuchprayoon, Somboon
    2019 IEEE INTERNATIONAL CONFERENCE ON ENVIRONMENT AND ELECTRICAL ENGINEERING AND 2019 IEEE INDUSTRIAL AND COMMERCIAL POWER SYSTEMS EUROPE (EEEIC / I&CPS EUROPE), 2019,
  • [39] Layout Optimization for a Large-Scale Grid-Connected Solar Power Plant
    Wang, Chong
    Wu, Qinghua
    Pan, Kai
    Shen, Zuo-Jun Max
    INFORMS JOURNAL ON COMPUTING, 2024,
  • [40] Power quality analysis of grid-connected solar photovoltaic generators in Brazil
    Urbanetz, Jair
    Braun, Priscila
    Ruether, Ricardo
    ENERGY CONVERSION AND MANAGEMENT, 2012, 64 : 8 - 14