Maximizing Annual Energy Yield in a Grid-Connected PV Solar Power Plant: Analysis of Seasonal Tilt Angle and Solar Tracking Strategies

被引:7
|
作者
Zaheb, Hameedullah [1 ,2 ]
Amiry, Habibullah [3 ]
Ahmadi, Mikaeel [1 ,4 ]
Fedayi, Habibullah [1 ]
Amiry, Sajida [2 ]
Yona, Atsushi [1 ]
机构
[1] Univ Ryukyus, Fac Engn, Dept Elect & Elect Engn, 1 Senbaru, Nishihara, Okinawa 9030213, Japan
[2] Kabul Univ, Fac Engn, Dept Energy Engn, Kabul 1006, Afghanistan
[3] Renewable Energy & Energy Efficiency Dept, Da Afghanistan Breshna Sherkat DABS, Kabul 1009, Afghanistan
[4] Univ Ryukyus, Cocreat Management Dept, Res Promot Unit, Nishihara, Okinawa 9030213, Japan
关键词
sustainable energy; sustainable development; energy yield; grid-connected PV; seasonal tilt; solar tracking; energy resilience; solar power generation; economic feasibility; SYSTEM; PERFORMANCE; OPTIMIZATION; TECHNOLOGY; REGION;
D O I
10.3390/su151411053
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Harnessing the abundant solar resources holds great potential for sustainable energy generation. This research paper delves into a comprehensive analysis of seasonal tilt and solar tracking strategy scenarios for a 15 MW grid-connected PV solar power plant situated in Kandahar province, Afghanistan. The study investigates the impact of fixed tilt, seasonal tilt, SAHST (single-axis horizontal solar tracking), and SAVST (single-axis vertical solar tracking) on energy yield, considering technical, economic, and environmental aspects. In the first scenario, a fixed tilt angle of 31 degrees was employed. The second scenario explored the use of seasonal tilt angles, with a summer tilt angle of 15 degrees and a winter tilt angle of 30 degrees. The third scenario analyzed SAHST. Finally, the fourth scenario focused on implementing SAVST. SAVST proved to be an exceptional solution, showcasing a remarkable increase in annual energy yield, and generating an additional 6680 MWh/year, 6336 MWh/year, and 5084 MWh/year compared to fixed, seasonal, and SAHST scenarios, respectively. As a result, surplus energy yielded an income of USD 554,440.00 per year compared to fixed tilt. However, the investment cost for the solar tracking system amounted to USD 1,451,932, accompanied by an annual operation and maintenance cost of 0.007 USD/W/year. The analysis revealed a promising payback period of 3 years, confirming the economic feasibility of this investment. The findings underscore the effectiveness of different strategies for optimizing solar power generation in the Kandahar region. Notably, the installation of SAVST emerged as an influential solution, significantly increasing power production. These research outcomes bear practical implications for solar tracking strategies for addressing the load challenges faced by Kandahar province and offer valuable insights for the operators and operation of solar power plants in similar regions.
引用
收藏
页数:20
相关论文
共 38 条
  • [21] Optimal Grid-Connected with Multi-Solar PV Placement and Sizing for Power Loss Reduction and Voltage Profile Improvement
    Seepromting, Katsarin
    Chatthaworn, Rongrit
    Khunkitti, Pirat
    Krusubthaworn, Anan
    Siritaratiwat, Apirat
    Surawanitkun, Chayada
    2018 18TH INTERNATIONAL SYMPOSIUM ON COMMUNICATIONS AND INFORMATION TECHNOLOGIES (ISCIT), 2018, : 479 - 483
  • [22] Design Optimization of Solar-Collector Tilt Angle for Annual-Maximum and Seasonal-Balanced Energy Received
    Alvarez, Adrian
    Pate, Michael B.
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2025, 147 (02):
  • [23] Optimization of a reliable grid-connected PV-based power plant with/without energy storage system by a heuristic approach
    Zebarjadi, Masoud
    Askarzadeh, Alireza
    SOLAR ENERGY, 2016, 125 : 12 - 21
  • [25] Evaluation of Energy Production and Energy Yield Assessment Based on Feasibility, Design, and Execution of 3x50MW Grid-Connected Solar PV Pilot Project in Nooriabad
    Jamil, Irfan
    Zhao, Jinquan
    Zhang, Li
    Jamil, Rehan
    Rafique, Syed Furqan
    INTERNATIONAL JOURNAL OF PHOTOENERGY, 2017, 2017
  • [26] Optimal Energy Management and Economic analysis of a grid-connected Hybrid Solar Water Heating System in Bloemfontein
    Hohne, Percy A.
    Kusakana, Kanzumba
    Numbi, Bubele P.
    2018 IEEE PES/IAS POWERAFRICA CONFERENCE, 2018, : 515 - 520
  • [27] Technoeconomic Analysis of 1 MWp Grid Connected Solar Power Plant in Konya (Türkiye)
    Sen, Mehmet
    Ozcan, Muciz
    TEHNICKI VJESNIK-TECHNICAL GAZETTE, 2023, 30 (06): : 1737 - 1743
  • [28] Assessing Techno-Economic Value of Battery Energy Storage with Grid-Connected Solar PV Compensation Schemes for Malaysian Commercial Prosumers
    Ilham, Nur Iqtiyani
    Dahlan, Nofri Yenita
    Hussin, Mohamad Zhafran
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2022, 12 (02): : 759 - 767
  • [29] Error Assessment of Solar Irradiance Forecasts and AC Power from Energy Conversion Model in Grid-Connected Photovoltaic Systems
    Chicco, Gianfranco
    Cocina, Valeria
    Di Leo, Paolo
    Spertino, Filippo
    Pavan, Alessandro Massi
    ENERGIES, 2016, 9 (01)
  • [30] Urban-scale distributed power generation - Forecast methods for the estimation of electricity exchange profiles for grid-connected solar photovoltaic (PV) systems
    Aste, N.
    Del Pero, C.
    2013 4TH INTERNATIONAL CONFERENCE ON CLEAN ELECTRICAL POWER (ICCEP): RENEWABLE ENERGY RESOURCES IMPACT, 2013, : 336 - 342