Accelerating image reconstruction for multi-contrast MRI based on Y-Net3+

被引:0
|
作者
Cai, Xin [1 ]
Hou, Xuewen [2 ]
Sun, Rong [1 ]
Chang, Xiao [1 ]
Zhu, Honglin [1 ]
Jia, Shouqiang [3 ]
Nie, Shengdong [1 ]
机构
[1] Univ Shanghai Sci & Technol, Sch Hlth Sci & Engn, Shanghai, Peoples R China
[2] Shanghai Kangda COLORFUL Healthcare Co Ltd, Shanghai, Peoples R China
[3] Shandong First Med Univ, Dept Imaging, Jinan Peoples Hosp, Shandong, Peoples R China
基金
中国国家自然科学基金; 上海市自然科学基金;
关键词
Magnetic resonance imaging; Deep learning; Multi-contrast MRI; Image reconstruction; Data consistency; NETWORKS;
D O I
10.3233/XST-230012
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
BACKGROUND: As one of the significant preoperative imaging modalities in medical diagnosis, Magnetic resonance imaging (MRI) takes a long scanning time due to its special imaging principle. OBJECTIVE: We propose an innovative MRI reconstruction strategy and data consistency method based on deep learning to reconstruct high-quality brain MRIs from down-sampled data and accelerate the MR imaging process. METHODS: Sixteen healthy subjects undergoing T1-weighted spin-echo (SE) and T2-weighted fast spin-echo (FSE) sequences by a 1.5T MRI scanner were recruited. A Y-Net3+ network was used to facilitate the high-quality MRI reconstruction through context information. In addition, the existing data consistency fidelity method was improved. The difference between the reconstructed K-space and the original K-space was shorten by the linear regression algorithm. Therefore, the redundant artifacts derived from under-sampling were avoided. The Structural Similarity (SSIM) and Peak Signal to Noise Ratio (PSNR) were applied to quantitatively evaluate image reconstruction performance of different down-sampling patterns. RESULTS: Compared with the classical Y-Net, Y-Net3+ network improved SSIM and PSNR of MRI images from 0.9164 +/- 0.0178 and 33.2216 +/- 3.2919 to 0.9387 +/- 0.0363 and 35.1785 +/- 3.3105, respectively, under compressed sensing reconstruction with acceleration factor of 4. The improved network increases signal-to-noise ratio and adds more image texture information in the reconstructed images. Furthermore, in the process of data consistency, linear regression analysis was used to reduce the difference between the reconstructed K-space and the original K-space, so that the SSIM and PSNR were increased to 0.9808 +/- 0.0081 and 40.9254 +/- 1.1911, respectively. CONCLUSIONS: The improved Y-Net combined with data consistency fidelity method elucidates its potential in reconstructing high-quality T2-weighted images from the down-sampled data by fully exploring the T1-weighted information. With the advantage of avoiding down-sampled artifacts, the improved network exhibits remarkable clinical promise for fast MRI applications.
引用
收藏
页码:797 / 810
页数:14
相关论文
共 50 条
  • [41] A review of deep learning-based reconstruction methods for accelerated MRI using spatiotemporal and multi-contrast redundancies
    Kim, Seonghyuk
    Park, HyunWook
    Park, Sung-Hong
    BIOMEDICAL ENGINEERING LETTERS, 2024, 14 (06) : 1221 - 1242
  • [42] Compressed Multi-Contrast Magnetic Resonance Image Reconstruction using Augmented Lagrangian Method
    Gungor, Alper
    Kopanoglu, Emre
    Cukur, Tolga
    Guven, H. Emre
    2016 24TH SIGNAL PROCESSING AND COMMUNICATION APPLICATION CONFERENCE (SIU), 2016, : 1985 - 1988
  • [43] A GAN BASED MULTI-CONTRAST MODALITIES MEDICAL IMAGE REGISTRATION APPROACH
    Qiao, Jinhao
    Lai, Qirong
    Li, Ying
    Lan, Ling
    Yu, Chunyan
    Wang, Xiu
    2020 IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2020, : 3000 - 3004
  • [44] Null Space Matters: Range-Null Decomposition for Consistent Multi-Contrast MRI Reconstruction
    Chen, Jiacheng
    Jiang, Jiawei
    Wu, Fei
    Zheng, Jianwei
    THIRTY-EIGHTH AAAI CONFERENCE ON ARTIFICIAL INTELLIGENCE, VOL 38 NO 2, 2024, : 1081 - 1090
  • [45] Fully Automatic 3D Glioma Extraction in Multi-contrast MRI
    Dvorak, Pavel
    Bartusek, Karel
    IMAGE ANALYSIS AND RECOGNITION, ICIAR 2014, PT II, 2014, 8815 : 239 - 246
  • [46] Deep Unfolding Convolutional Dictionary Model for Multi-Contrast MRI Super-resolution and Reconstruction
    Lei, Pengcheng
    Fang, Faming
    Zhang, Guixu
    Xu, Ming
    PROCEEDINGS OF THE THIRTY-SECOND INTERNATIONAL JOINT CONFERENCE ON ARTIFICIAL INTELLIGENCE, IJCAI 2023, 2023, : 1008 - 1016
  • [47] High-dimensionality undersampled patch-based reconstruction (HD-PROST) for accelerated multi-contrast MRI
    Bustin, Aurelien
    da Cruz, Gastao Lima
    Jaubert, Olivier
    Lopez, Karina
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (06) : 3705 - 3719
  • [48] Multi-contrast multi-shot EPI for accelerated diffusion MRI
    Shafieizargar, Banafshe
    Jeurissen, Ben
    Poot, Dirk H. J.
    den Dekker, Arnold J.
    Sijbers, Jan
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 3869 - 3872
  • [49] Improving Image Synthesis Quality in Multi-Contrast MRI Using Transfer Learning via Autoencoders
    Selcuk, Saban Yoruc
    Dalmaz, Onat
    Dar, Salman ul Hassan
    Cukur, Tolga
    2022 30TH SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE, SIU, 2022,
  • [50] DSFormer: A Dual-domain Self-supervised Transformer for Accelerated Multi-contrast MRI Reconstruction
    Zhou, Bo
    Dey, Neel
    Liu, Chi
    Schlemper, Jo
    Duncan, James S.
    Salehi, Seyed Sadegh Mohseni
    Sofka, Michal
    2023 IEEE/CVF WINTER CONFERENCE ON APPLICATIONS OF COMPUTER VISION (WACV), 2023, : 4955 - 4964