Contrast-enhanced Ultrasound (CEUS)-based Characterization Solid Renal Masses: A role for quantitative imaging approaches

被引:0
|
作者
Varghese, Bino A. [1 ]
Rivas, Marielena [2 ]
Cen, Steven [1 ]
Lei, Xiaomeng [1 ]
Chang, Michael [3 ]
Lee, KwangJu [4 ]
Gunter, Jamie [1 ]
Amoedo, Renata L. [5 ]
Franco, Mario [1 ]
Hwang, Darryl H. [1 ]
Desai, Bhushan [1 ]
King, Kevin G. [6 ]
Cheng, Phillip M. [1 ]
Duddalwar, Vinay [1 ]
机构
[1] Univ Southern Calif, Keck Sch Med, Los Angeles, CA 90007 USA
[2] Univ Richmond, Med Ctr, New York, NY USA
[3] Icahn Sch Med Mt Sinai, New York, NY USA
[4] Samsung Medison Co Ltd, Seoul, South Korea
[5] Hosp Sao Rafael Rede Dor, Salvador, BA, Brazil
[6] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA USA
来源
18TH INTERNATIONAL SYMPOSIUM ON MEDICAL INFORMATION PROCESSING AND ANALYSIS | 2023年 / 12567卷
关键词
CEUS; Radiomics; TIC; renal masses; visual assessment;
D O I
10.1117/12.2670366
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In this prospective study, forty patients with solid renal masses who underwent contrast-enhanced ultrasound (CEUS) examinations were selected. Using the ImageJ software, renal masses and adjacent normal tissue were manually segmented from CEUS cine exams obtained using the built-in RS85 Samsung scanner software. For the radiomics analysis, one frame representing precontrast, early, peak, and delay enhancement phase were selected post segmentation from each CEUS clip. From each region of interest (ROI) within a tumor tissue normalized renal mass, 112 radiomic metrics were extracted using custom Matlab (R) code. For the time-intensity curve (TIC) analysis, the segmented ROIs were plotted as a function of time, and the data were fit to a washout curve. From these time-signal intensity curves, perfusion quantitative parameters, were generated. Wilcoxon rank sum test or univariate independent t-test depending on data normality were used for descriptive analyses. Agreement was analyzed using Kappa statistic. Of the 40 solid masses, 31 (77.5%) were malignant, 9 (22.5%) were benign based on histopathology. Excellent agreement was found between histopathological confirmation and visual assessment based on CEUS in discriminating solid renal masses into benign vs. malignant categories (kappa=0.89 95% confidence interval ( CI): (0.77,1)). The total agreement between the two was 92.5%. The sensitivity and specificity of CEUS-based visual assessment was found to be 100% and 66.7%, respectively. Quantitative analysis revealed TIC metrics revealed statistically significant differences between the malignant and benign groups and between clear cell renal cell carcinoma (ccRCC) and papillary renal cell carcinoma (pRCC) subtypes. The study shows excellent agreement between visual assessment and histopathology, but with the room to improve in specificity.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Diagnostic Performance of Contrast-Enhanced Ultrasound (CEUS) in the Evaluation of Solid Renal Masses
    Geyer, Thomas
    Schwarze, Vincent
    Marschner, Constantin
    Schnitzer, Moritz L.
    Froelich, Matthias F.
    Ruebenthaler, Johannes
    Clevert, Dirk-Andre
    MEDICINA-LITHUANIA, 2020, 56 (11): : 1 - 8
  • [2] Contrast-enhanced ultrasound for characterizing renal masses
    Bertolotto, Michele
    Bucci, Stefano
    Valentino, Massimo
    Curro, Francesca
    Sachs, Camilla
    Cova, Maria Assunta
    EUROPEAN JOURNAL OF RADIOLOGY, 2018, 105 : 41 - 48
  • [3] Renal Complex Cystic Masses: Usefulness of Contrast-Enhanced Ultrasound (CEUS) in Their Assessment and Its Agreement with Computed Tomography
    Sanz, Enrique
    Hevia, Vital
    Gomez, Victoria
    Alvarez, Sara
    Fabuel, Jose-Javier
    Martinez, Laura
    Rodriguez-Patron, Rafael
    Gonzalez-Gordaliza, Cristina
    Burgos, Francisco-Javier
    CURRENT UROLOGY REPORTS, 2016, 17 (12)
  • [4] Renal Complex Cystic Masses: Usefulness of Contrast-Enhanced Ultrasound (CEUS) in Their Assessment and Its Agreement with Computed Tomography
    Enrique Sanz
    Vital Hevia
    Victoria Gómez
    Sara Álvarez
    Jose-Javier Fabuel
    Laura Martínez
    Rafael Rodriguez-Patrón
    Cristina González-Gordaliza
    Francisco-Javier Burgos
    Current Urology Reports, 2016, 17
  • [5] Renal Masses With Equivocal Enhancement at CT: Characterization With Contrast-Enhanced Ultrasound
    Bertolotto, Michele
    Cicero, Calogero
    Perrone, Rosaria
    Degrassi, Ferruccio
    Cacciato, Francesca
    Cova, Maria A.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (05) : W557 - W565
  • [6] The value of contrast enhanced ultrasound (CEUS) in the characterisation of patients with renal masses
    Ignee, Andre
    Straub, Bernd
    Brix, David
    Schuessler, Gudrun
    Ott, Michaela
    Dietrich, Christoph F.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2010, 46 (04) : 275 - 290
  • [7] Contrast-enhanced ultrasound (CEUS) and perfusion imaging using VueBox®
    Wiesinger, Isabel
    Jung, Friedrich
    Jung, Ernst Michael
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2021, 78 (01) : 29 - 40
  • [8] Contrast-enhanced ultrasound (CEUS) in renal imaging at an interdisciplinary ultrasound centre: Possibilities of dynamic microvascularisation and perfusion
    Putz, Franz Josef
    Erlmeier, Anna
    Wiesinger, Isabel
    Verloh, Niklas
    Stroszczynski, Christian
    Banas, Bernhard
    Jung, Ernst Michael
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2017, 66 (04) : 293 - 302
  • [9] Contrast-Enhanced Ultrasound (CEUS) of Pancreatic Cancer
    D’Onofrio M.
    Ciaravino V.
    Crosara S.
    De Robertis R.
    Pozzi Mucelli R.
    Current Radiology Reports, 3 (3)
  • [10] CHARACTERIZATION AND DIAGNOSTIC CONFIDENCE OF CONTRAST-ENHANCED ULTRASOUND FOR SOLID RENAL TUMORS
    Zhou, Xiang
    Yan, Feng
    Luo, Yan
    Peng, Yu-Lan
    Parajuly, Shyam Sundar
    Wen, Xiao-Rong
    Cai, Di-Ming
    Li, Yong-Zhong
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2011, 37 (06) : 845 - 853