Feasibility study of dynamic thermal-modeling development using measurement and validation: Case study of indoor fish farm

被引:8
作者
Goo, Jabin [1 ]
Kwak, Younghoon [2 ]
Shin, Hakjong [1 ]
Kim, Jiwon [1 ]
Jo, Seng-Kyoun [3 ]
Huh, Jung -Ho [2 ]
机构
[1] Univ Seoul, Dept Architectural Engn, 163 Seoulsiripdae Ro, Seoul 02504, South Korea
[2] Univ Seoul, Dept Architecture, 163 Seoulsiripdae Ro, Seoul 02504, South Korea
[3] Elect & Telecommun Res Inst, Agr Anim & Aquaculture Intelligence Res Ctr, 218 Gajeong Ro, Daejeon 34129, South Korea
关键词
Indoor fish farm; Thermal performance; Validation; Parameter analysis; Feasibility study; ENERGY-CONSUMPTION; PERFORMANCE; SIMULATION; SYSTEM;
D O I
10.1016/j.applthermaleng.2023.120512
中图分类号
O414.1 [热力学];
学科分类号
摘要
Since energy consumption in buildings relies primarily on their purpose as opposed to the type of occupants, relatively high energy is also consumed in the indoor fish farms where people do not live. In particular, energy consumption of indoor fish farms has been increasing for the high productivity and economic efficiency. Therefore, a feasibility study of dynamic thermal modeling development for indoor fish farms is critical to analyze energy consumption. In this study, an indoor fish farm thermal model was developed, and the feasibility of the model was analyzed using onsite indoor temperature, relative humidity, and water temperature data. Further, the major sensitive variables in model development and their effects were investigated. The errors between measured and predicted results obtained using the developed thermal model were within hourly acceptable limits, which means the developed thermal model was valid. The activity factor (AF) and air change per hour (ACH), which are the major sensitive variables, significantly affected thermal performance such as evaporation loss, indoor temperature, relative humidity and water temperature. The average indoor relative humidity increased by approximately 16% when AF increased from 0 to 2. The average evaporation loss of the fish farm increased by 20.9 kW to 49 kW when ACH was 10. Therefore, similar to an indoor fish farm, the effects of aeration, opening/closing of windows and doors must be considered for simulations during energy-model development and future improvements. The results suggest that the proposed thermal model for indoor fish farms can be used to develop an energy model and expanded to various fields for predicting energy consumption and optimal control.
引用
收藏
页数:18
相关论文
共 56 条
[11]   Critical comparison between thermal performance test (TPT) and thermal response test (TRT): Differences in heat transfer process and extractable information [J].
Choi, Wonjun ;
Kikumoto, Hideki ;
Ooka, Ryozo .
ENERGY CONVERSION AND MANAGEMENT, 2019, 199
[12]   Energy and resource consumption of land-based Atlantic salmon smolt hatcheries in the Pacific Northwest (USA) [J].
Colt, John ;
Summerfelt, Steve ;
Pfeiffer, Tim ;
Fivelstad, Sveinung ;
Rust, Michael .
AQUACULTURE, 2008, 280 (1-4) :94-108
[13]   Optimizing photovoltaic electric generation and roof insulation in existing residential buildings [J].
D'Agostino, Delia ;
Parker, Danny ;
Melia, Paco ;
Dotelli, Giovanni .
ENERGY AND BUILDINGS, 2022, 255
[14]   Water quality and rainbow trout performance in a Danish Model Farm recirculating system: Comparison with a flow through system [J].
d'orbcastel, Emmanuelle Roque ;
Blancheton, Jean-Paul ;
Belaud, Alain .
AQUACULTURAL ENGINEERING, 2009, 40 (03) :135-143
[15]   Towards environmentally sustainable aquaculture: Comparison between two trout farming systems using Life Cycle Assessment [J].
d'Orbcastel, Emmanuelle Roque ;
Blancheton, Jean-Paul ;
Aubin, Joel .
AQUACULTURAL ENGINEERING, 2009, 40 (03) :113-119
[16]   Temperature modeling of a land-based aquaculture system for the production of Gracilaria pacifica: Possible system modifications to conserve heat and extend the growing season [J].
Davison, Andrew V. ;
Piedrahita, Raul H. .
AQUACULTURAL ENGINEERING, 2015, 66 :1-10
[17]  
DOE, 2020, ENERGYPLUS ENG REF
[18]  
energyplus.net, about us
[19]   Control methodologies based on geothermal recirculating aquaculture system [J].
Farghally, Hanaa M. ;
Atia, Doaa M. ;
El-Madany, Hanaa T. ;
Fahmy, Faten H. .
ENERGY, 2014, 78 :826-833
[20]   A multiple regression approach for calibration of residential building energy models [J].
Fumo, Nelson ;
Torres, Maria Josefina ;
Broomfield, Kayla .
JOURNAL OF BUILDING ENGINEERING, 2021, 43