Reproducibility of [18F]FDG PET/CT liver SUV as reference or normalisation factor

被引:19
|
作者
Zwezerijnen, Gerben J. C. [1 ,2 ]
Eertink, Jakoba J. [2 ,3 ]
Ferrandez, Maria C. [1 ,2 ]
Wiegers, Sanne E. [1 ,2 ]
Burggraaff, Coreline N. [3 ]
Lugtenburg, Pieternella J. [4 ]
Heymans, Martijn W. [5 ,6 ]
de Vet, Henrica C. W. [5 ,6 ]
Zijlstra, Josee M. [2 ,3 ]
Boellaard, Ronald [1 ,2 ]
机构
[1] Amsterdam UMC Locat Vrije Univ Amsterdam, Radiol & Nucl Med, Amsterdam, Netherlands
[2] Canc Ctr Amsterdam, Imaging & Biomarkers, Amsterdam, Netherlands
[3] Amsterdam UMC Locat Vrije Univ Amsterdam, Hematol, Amsterdam, Netherlands
[4] Univ Med Ctr, Erasmus MC Canc Inst, Hematol, Rotterdam, Netherlands
[5] Amsterdam UMC Locat Vrije Univ Amsterdam, Epidemiol & Data Sci, Boelelaan 1117, Amsterdam, Netherlands
[6] Amsterdam Publ Hlth Res Inst, Methodol, Amsterdam, Netherlands
关键词
Liver uptake; Reference; VOI; 18F]FDG PET; CT; EMISSION TOMOGRAPHY/COMPUTED TOMOGRAPHY; METABOLIC TUMOR VOLUME; STANDARD UPTAKE VALUES; B-CELL LYMPHOMA; F-18-FDG UPTAKE; FDG UPTAKE; ONCOLOGY; BRAIN; NOISE; QUANTIFICATION;
D O I
10.1007/s00259-022-05977-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Introduction Although visual and quantitative assessments of [18F]FDG PET/CT studies typically rely on liver uptake value as a reference or normalisation factor, consensus or consistency in measuring [18F]FDG uptake is lacking. Therefore, we evaluate the variation of several liver standardised uptake value (SUV) measurements in lymphoma [18F]FDG PET/CT studies using different uptake metrics. Methods PET/CT scans from 34 lymphoma patients were used to calculate SUVmax(liver), SUVpeak(liver) and SUVmean(liver) as a function of (1) volume-of-interest (VOI) size, (2) location, (3) imaging time point and (4) as a function of total metabolic tumour volume (MTV). The impact of reconstruction protocol on liver uptake is studied on 15 baseline lymphoma patient scans. The effect of noise on liver SUV was assessed using full and 25% count images of 15 lymphoma scans. Results Generally, SUVmax(liver) and SUVpeak(liver) were 38% and 16% higher compared to SUVmean(liver). SUVmax(liver) and SUVpeak(liver) increased up to 31% and 15% with VOI size while SUVmean(liver) remained unchanged with the lowest variability for the largest VOI size. Liver uptake metrics were not affected by VOI location. Compared to baseline, liver uptake metrics were 15-18% and 9-18% higher at interim and EoT PET, respectively. SUVliver decreased with larger total MTVs. SUVmax(liver) and SUVpeak(liver) were affected by reconstruction protocol up to 62%. SUVmax and SUVpeak moved 22% and 11% upward between full and 25% count images. Conclusion SUVmean(liver) was most robust against VOI size, location, reconstruction protocol and image noise level, and is thus the most reproducible metric for liver uptake. The commonly recommended 3 cm diameter spherical VOI-based SUVmean(liver) values were only slightly more variable than those seen with larger VOI sizes and are sufficient for SUVmean(liver) measurements in future studies.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 50 条
  • [1] Reproducibility of [18F]FDG PET/CT liver SUV as reference or normalisation factor
    Gerben J. C. Zwezerijnen
    Jakoba J. Eertink
    Maria C. Ferrández
    Sanne E. Wiegers
    Coreline N. Burggraaff
    Pieternella J. Lugtenburg
    Martijn W. Heymans
    Henrica C. W. de Vet
    Josée M. Zijlstra
    Ronald Boellaard
    European Journal of Nuclear Medicine and Molecular Imaging, 2023, 50 : 486 - 493
  • [2] Interchangeability of radiomic features between [18F]-FDG PET/CT and [18F]-FDG PET/MR
    Diem Vuong
    Tanadini-Lang, Stephanie
    Huellner, Martin W.
    Veit-Haibach, Patrick
    Unkelbach, Jan
    Andratschke, Nicolaus
    Kraft, Johannes
    Guckenberger, Matthias
    Bogowicz, Marta
    MEDICAL PHYSICS, 2019, 46 (04) : 1677 - 1685
  • [3] [18F]FAPI PET/CT in the evaluation of focal liver lesions with [18F]FDG non-avidity
    Zhang, Jing
    He, Qiao
    Jiang, Shuqin
    Li, Mengsi
    Xue, Haibao
    Zhang, Donghui
    Li, Shuyi
    Peng, Hao
    Liang, Jiucen
    Liu, Zhidong
    Rao, Songquan
    Wang, Jin
    Zhang, Rusen
    Zhang, Linqi
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2023, 50 (03) : 937 - 950
  • [4] [18F]FDG PET/CT versus [18F]FDG PET/MRI for the diagnosis of colorectal liver metastasis: A systematic review and meta-analysis
    Miao, Zhi
    Zhao, Xiaomeng
    Li, Xuanwen
    FRONTIERS IN ONCOLOGY, 2023, 13
  • [5] PET/CT in patients with hepatocellular carcinoma using [18F]fluorocholine: preliminary comparison with [18F]FDG PET/CT
    Jean-Noël Talbot
    Fabrice Gutman
    Laetitia Fartoux
    Jean-Didier Grange
    Nathalie Ganne
    Khaldoun Kerrou
    Dany Grahek
    Françoise Montravers
    Raoul Poupon
    Olivier Rosmorduc
    European Journal of Nuclear Medicine and Molecular Imaging, 2006, 33 : 1285 - 1289
  • [6] PET/CT in patients with hepatocellular carcinoma using [18F] fluorocholine:: preliminary comparison with [18F]FDG PET/CT
    Talbot, Jean-Noël
    Gutman, Fabrice
    Fartoux, Laetitia
    Grange, Jean-Didier
    Ganne, Nathalie
    Kerrou, Khaldoun
    Grahek, Dany
    Montravers, Francoise
    Poupon, Raoul
    Rosmorduc, Olivier
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 (11) : 1285 - 1289
  • [7] [18F]FDG PET/CT imaging of spinal infections
    te Beek, Erik T.
    ten Broek, Marc R. J.
    Abdul-Fatah, Sakar
    Glaudemans, Andor W. J. M.
    CLINICAL AND TRANSLATIONAL IMAGING, 2024, 12 (05) : 527 - 539
  • [8] Optimization of SUV with Changing the Dose Amount in F18-FDG PET/CT of Pediatric Lymphoma Patients
    Gulaldi, Nedim Cuneyt Murat
    Cagdas, Berkay
    Gortan, Fatma Arzu
    CURRENT RADIOPHARMACEUTICALS, 2023, 16 (02) : 151 - 157
  • [9] Reference Range for Intrapatient Variability in Blood-Pool and Liver SUV for 18F-FDG PET
    Boktor, Raef R.
    Walker, Gregory
    Stacey, Roderick
    Gledhill, Samuel
    Pitman, Alexander G.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (05) : 677 - 682
  • [10] Reproducibility of functional volume and activity concentration in 18F-FDG PET/CT of liver metastases in colorectal cancer
    Heijmen, Linda
    de Geus-Oei, Lioe-Fee
    de Wilt, Johannes H. W.
    Visvikis, Dimitris
    Hatt, Mathieu
    Visser, Eric P.
    Bussink, Johan
    Punt, Cornelis J. A.
    Oyen, Wim J. G.
    van Laarhoven, Hanneke W. M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (12) : 1858 - 1867