Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty

被引:0
作者
Cosendey, Killian [1 ,2 ]
Stanovici, Julien [1 ,2 ]
Cadas, Hugues [3 ]
Omoumi, Patrick [2 ,4 ]
Jolles, Brigitte M. [1 ,2 ,5 ]
Favre, Julien [1 ,2 ,6 ]
机构
[1] Lausanne Univ Hosp, Dept Musculoskeletal Med, CH-1011 Lausanne, Switzerland
[2] Univ Lausanne UNIL, CHUV, CH-1011 Lausanne, Switzerland
[3] Univ Lausanne UNIL, Morphol & Anat Fac Unit, CH-1005 Lausanne, Switzerland
[4] Lausanne Univ Hosp, Dept Diagnost & Intervent Radiol, CH-1011 Lausanne, Switzerland
[5] Ecole Polytech Fed Lausanne EPFL, Inst Elect & Micro Engn, CH-1015 Lausanne, Switzerland
[6] Sense Innovat & Res Ctr, CH-1007 Lausanne, Switzerland
关键词
total knee arthroplasty; robotic-assisted surgery; accuracy; bone cuts and implant placements; position and orientation errors; ALIGNMENT; NAVIGATION; RESECTION; TKA;
D O I
10.3390/jcm13051293
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: This study aimed to evaluate the accuracy of bone cuts and implant placements, simultaneously, for total knee arthroplasty (TKA) performed using a system with an active robotic arm. Methods: Two experienced orthopaedic surgeons performed TKA on ten cadaveric legs. Computed tomography scans were performed to compare the bone cuts and implant placements with the preoperative planning. The differences between the planned and actual bone cuts and implant placements were assessed using positional and angular errors in the three anatomical planes. Additionally, the cut-implant deviations were calculated. Statistical analysis was performed to detect systematic errors in the bone cuts and implant placements and to quantify the correlations between these errors. Results: The root-mean-square (RMS) errors of the bone cuts (with respect to the planning) were between 0.7-1.5 mm and 0.6-1.7 degrees. The RMS implant placement errors (with respect to the planning) varied between 0.6-1.6 mm and 0.4-1.5 degrees, except for the femur and tibia in the sagittal plane (2.9 degrees). Systematic errors in the bone cuts and implant placements were observed, respectively, in three and two degrees of freedom. For cut-implant deviations, the RMS values ranged between 0.3-2.0 mm and 0.6-1.9 degrees. The bone cut and implant placement errors were significantly correlated in eight degrees-of-freedom (rho >= 0.67, p < 0.05). Conclusions: With most of the errors below 2 mm or 2 degrees, this study supported the value of active robotic TKA in achieving accurate bone cuts and implant placements. The findings also highlighted the need for both accurate bone cuts and proper implantation technique to achieve accurate implant placements.
引用
收藏
页数:12
相关论文
共 24 条
[1]   Computer assisted navigation in total knee arthroplasty - Comparison with conventional methods [J].
Anderson, KC ;
Buehler, KC ;
Markel, DC .
JOURNAL OF ARTHROPLASTY, 2005, 20 (07) :132-138
[2]   Robotics in Total Knee Arthroplasty [J].
Bautista, Maria ;
Manrique, Jorge ;
Hozack, William J. .
JOURNAL OF KNEE SURGERY, 2019, 32 (07) :600-606
[3]  
Boas FE., 2012, Imaging Med, V4, P229
[4]   Accuracy assessment of a novel image-free handheld robot for Total Knee Arthroplasty in a cadaveric study [J].
Casper, Michael ;
Mitra, Riddhit ;
Khare, Rahul ;
Jaramaz, Branislav ;
Hamlin, Brian ;
McGinley, Brian ;
Mayman, David ;
Headrick, Jeff ;
Urish, Kenneth ;
Gittins, Mark ;
Incavo, Stephen ;
Neginhal, Vivek .
COMPUTER ASSISTED SURGERY, 2018, 23 (01) :14-20
[5]   Alignment deviation between bone resection and final implant positioning in computer-navigated total knee arthroplasty [J].
Catani, Fabio ;
Biasca, Nicola ;
Ensini, Andrea ;
Leardini, Alberto ;
Bianchi, Luca ;
Digennaro, Vitantonio ;
Giannini, Sandro .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :765-771
[6]   Does Accurate Anatomical Alignment Result in Better Function and Quality of Life? Comparing Conventional and Computer-Assisted Total Knee Arthroplasty [J].
Choong, Peter F. ;
Dowsey, Michelle M. ;
Stoney, James D. .
JOURNAL OF ARTHROPLASTY, 2009, 24 (04) :560-569
[7]   Navigated total knee arthroplasty: is it error-free? [J].
Chua, Kerk Hsiang Zackary ;
Chen, Yongsheng ;
Lingaraj, Krishna .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2014, 22 (03) :643-649
[8]   Bone Cuts Accuracy of a System for Total Knee Arthroplasty including an Active Robotic Arm [J].
Cosendey, Killian ;
Stanovici, Julien ;
Mahlouly, Jaad ;
Omoumi, Patrick ;
Jolles, Brigitte M. ;
Favre, Julien .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (16)
[9]   Robotic-assisted knee arthroplasty: an evolution in progress. A concise review of the available systems and the data supporting them [J].
Elliott, Johanna ;
Shatrov, Jobe ;
Fritsch, Brett ;
Parker, David .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) :2099-2117
[10]   Analyzing Femorotibial Cartilage Thickness Using Anatomically Standardized Maps: Reproducibility and Reference Data [J].
Favre, Julien ;
Babel, Hugo ;
Cavinato, Alessandro ;
Blazek, Katerina ;
Jolles, Brigitte M. ;
Andriacchi, Thomas P. .
JOURNAL OF CLINICAL MEDICINE, 2021, 10 (03) :1-12