INFLUENCE OF VENTILATION TO LIMIT AIRBORNE INFECTION CONCENTRATION IN AN ISOLATION ROOM

被引:0
作者
Kassem, Fatma A. -M. [1 ]
Abdelgawad, Ahmed Farouk [2 ]
Abu El-Ezz, A. E. [3 ]
Nassief, Mofreh M. [2 ]
Adel, Mohamed [2 ]
机构
[1] Natl Inst Stand, Dept Volume & Fluid Flow Metrol Lab, Giza, Egypt
[2] Zagazig Univ, Fac Engn, Dept Mech Power Engn, Zagazig, Egypt
[3] Natl Inst Stand, Dept Force & Mat Metrol Lab, Giza, Egypt
来源
ENVIRONMENT PROTECTION ENGINEERING | 2023年 / 49卷 / 02期
关键词
AIR-DISTRIBUTION; TRANSMISSION; PERFORMANCE; FLOW;
D O I
10.37190/epe230204
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Coronavirus (COVID-19) was detected at the end of 2019 and has since caused a worldwide pan-demic. This virus is transferred airborne. In this study, an investigation was carried out of the ventila-tion strategies inside the isolation room based on exhaust air locations. To reduce the infection disease (COVID-19), due to the spreading of exhaled contaminants by humans in interior environments, five models for ventilation systems differing in the position of the outlet and inlet were used. This study aims to increase knowledge regarding the exhaled contaminant distribution under different environ-mental conditions (opening exhaust and negative pressure). The results showed a good agreement be-tween the computational results and the experimental data. Tracer gas CO2 was used to evaluate the air quality experimentally and computationally. The results showed that stable conditions are obtained inside the room at a negative pressure value above -1.5 Pa. The residence time of the infected airborne decreases when the pressure difference increases. The study revealed that the model with an air outlet opening installed behind the patient enabled avoiding the spread of infection in the room.
引用
收藏
页码:39 / 54
页数:16
相关论文
共 50 条
  • [41] Why do ventilation strategies matter in controlling infectious airborne particles? A comprehensive numerical analysis in isolation ward
    Tan, Huiyi
    Wong, Keng Yinn
    Othman, Mohd Hafiz Dzarfan
    Kek, Hong Yee
    Nyakuma, Bemgba Bevan
    Ho, Wai Shin
    Hashim, Haslenda
    Wahab, Roswanira Abdul
    Sheng, Desmond Daniel Chin Vui
    Wahab, Nur Haliza Abdul
    Yatim, Ardiyansyah Saad
    BUILDING AND ENVIRONMENT, 2023, 231
  • [42] INFLUENCE OF VENTILATION SYSTEM TYPE ON MICROCLIMATE PARAMETERS IN FARROWING ROOM AND REPRODUCTIVE QUALITIES OF PIGS
    Mykhalko, Oleksandr
    Povod, Mykola
    Gutyj, Bogdan
    Lumedze, Iminjon
    Iovenko, Artem
    Bondar, Alla
    SCIENTIFIC PAPERS-SERIES MANAGEMENT ECONOMIC ENGINEERING IN AGRICULTURE AND RURAL DEVELOPMENT, 2023, 23 (01) : 425 - 436
  • [43] Estimating ventilation rates in a window-aired room using Kalman filtering and considering uncertain measurements of occupancy and CO2 concentration
    Duarte, Rogerio
    Gomes, Maria Gloria
    Rodrigues, Antonio Moret
    BUILDING AND ENVIRONMENT, 2018, 143 : 691 - 700
  • [44] Evaluation of airborne contaminant exposure in a single-bed isolation ward equipped with a protected occupied zone ventilation system
    Aganovic, Amar
    Cao, Guangyu
    INDOOR AND BUILT ENVIRONMENT, 2019, 28 (08) : 1092 - 1103
  • [45] Seasonal variation in airborne infection risk in schools due to changes in ventilation inferred from monitored carbon dioxide
    Vouriot, Carolanne V. M.
    Burridge, Henry C.
    Noakes, Catherine J.
    Linden, Paul F.
    INDOOR AIR, 2021, 31 (04) : 1154 - 1163
  • [46] The ventilation needed to control thermal plume and particle dispersion from manikins in a unidirectional ventilated protective isolation room
    Caiqing Yang
    Xudong Yang
    Bin Zhao
    Building Simulation, 2015, 8 : 551 - 565
  • [47] Estimation of airborne infection risk in a school classroom according to operation of a floor-standing type ventilation system
    Shin, Hee Won
    Kang, Dong Hwa
    JOURNAL OF BUILDING ENGINEERING, 2023, 78
  • [48] A simplified methodology for the prediction of mean air velocity and particle concentration in isolation rooms with downward ventilation systems
    Wang, Bing
    Zhao, Bin
    Chen, Chun
    BUILDING AND ENVIRONMENT, 2010, 45 (08) : 1847 - 1853
  • [49] Influence of Natural Convection Ventilation of the Space Between the Roof and the False Ceiling on the Distribution of the Temperature in a Room
    Tarek, Djeldjeli
    Benamara, Nabil
    Aminallah, Miloud
    Lahcene, Abdelkader
    Tewfik, Sereir
    INTERNATIONAL JOURNAL OF HEAT AND TECHNOLOGY, 2023, 41 (03) : 749 - 754
  • [50] THE INFLUENCE OF THE VENTILATION SYSTEM IN THE ROOM FOR REARING PIGS AND THE TYPE OF FEEDING ON THE INDICATORS OF MICROCLIMATE AND PRODUCTIVITY OF PIGS
    Mykhalko, Oleksandr
    Povod, Mykola
    Gutyj, Bogdan
    Korzh, Olga
    Mironenko, Olena
    Karunna, Tatiana
    Bilokopytov, Vasyl
    Krempa, Nadiia
    SCIENTIFIC PAPERS-SERIES MANAGEMENT ECONOMIC ENGINEERING IN AGRICULTURE AND RURAL DEVELOPMENT, 2024, 24 (01) : 635 - 652