Novel anti-reflux biliary metal stent with a distal tapered end for distal malignant biliary obstruction: a feasibility study

被引:0
作者
Doi, Shinpei [1 ,3 ]
Namura, Yuta [1 ]
Kikuyama, Tomohiro [1 ]
Saito, Go [1 ]
Adachi, Takako [1 ]
Matsumoto, Kotaro [1 ]
Watanabe, Ayako [1 ]
Tsunashima, Hiromichi [1 ]
Katsukura, Nobuhiro [1 ]
Tsujikawa, Takayuki [1 ]
Yasuda, Ichiro [2 ]
机构
[1] Teikyo Univ, Mizonokuchi Hosp, Dept Gastroenterol, Kanagawa, Japan
[2] Univ Toyama, Dept Internal Med 3, Toyama, Japan
[3] Teikyo Univ, Mizonokuchi Hosp, Dept Gastroenterol, 5-1-1 Futago,Takatsu Ku, Kawasaki 2138507, Japan
关键词
ENDOSCOPIC SPHINCTEROTOMY; RANDOMIZED-TRIAL; RISK-FACTORS; STRICTURES; MANAGEMENT; PLACEMENT; MIGRATION; REDUCE; VALVE;
D O I
10.1055/a-2039-3853
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and study aims We developed a self-expandable metallic stent (SEMS) with a distal tapered end to reproduce the physiological bile flow with a pressure gradient due to the difference in the diameter. We aimed to evaluate the safety and efficacy of the newly developed distal tapered covered metal stent (TMS) for distal malignant biliary obstruction (DMBO).Patients and methods This single-center, prospective, single-arm study was conducted in patients with DMBO. The primary endpoint was time to recurrent biliary obstruction (TRBO), and the secondary endpoints were the survival time and incidence of adverse events (AEs).Results Thirty-five patients (15 men, 20 women; median age, 81 years [range: 53-92]) were enrolled between December 2017 and December 2019. The primary diseases were pancreatic head cancer in 25 cases, bile duct cancer in eight cases, and ampullary cancer in two cases. TMS was successfully placed in all cases. Acute cholecystitis occurred as an early AE (within 30 days) in two cases (5.7 %). The median TRBO was 503 days, median survival time was 239 days. RBO was observed in 10 cases (28.6 %), and the causes were distal migration in six cases, proximal migration in two cases, biliary sludge in one case, and tumor overgrowth in one case.Conclusions Endoscopic placement of the newly developed TMS in patients with DMBO is technically feasible and safe, and the TRBO was remarkably long. The anti-reflux mechanism based on the difference in diameter may be effective, and a randomized controlled trial with a conventional SEMS is required.
引用
收藏
页码:E460 / E465
页数:6
相关论文
共 50 条
[21]   Management of distal malignant biliary obstruction [J].
Aljahdli, Emad S. .
SAUDI JOURNAL OF GASTROENTEROLOGY, 2018, 24 (02) :71-72
[22]   Feasibility of Double-Deployment Small-Diameter Covered Metallic Stent for Malignant Distal Biliary Obstruction (with Video) [J].
Nakano, Ryota ;
Shiomi, Hideyuki ;
Okamoto, Mamiko ;
Kawase, Yuta ;
Yoshihara, Kohei ;
Yoshioka, Ryota ;
Kawata, Shoki ;
Yuri, Yukihisa ;
Takashima, Tomoyuki ;
Aizawa, Nobuhiro ;
Ikeda, Naoto ;
Nishimura, Takashi ;
Fukunishi, Shinya ;
Enomoto, Hirayuki .
DIAGNOSTICS, 2024, 14 (19)
[23]   Predictors of Recurrent Biliary Obstruction Following Percutaneous Uncovered Metal Stent Insertion in Patients with Distal Malignant Biliary Obstruction: An Analysis Using a Competing Risk Model [J].
Zhang, Jin-Xing ;
Wang, Bin ;
Liu, Sheng ;
Zu, Qing-Quan ;
Shi, Hai-Bin .
CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2019, 42 (02) :276-282
[24]   Efficacy and safety of a novel polytetrafluoroethylene-coated self-expandable metal stent for distal malignant biliary obstruction [J].
Nakagawa, Hiroki ;
Takeda, Tsuyoshi ;
Okamoto, Takeshi ;
Hirai, Tatsuki ;
Mie, Takafumi ;
Furukawa, Takaaki ;
Kasuga, Akiyoshi ;
Sasaki, Takashi ;
Ozaka, Masato ;
Matsuda, Takahisa ;
Igarashi, Yoshinori ;
Sasahira, Naoki .
DEN OPEN, 2025, 5 (01)
[25]   Feasibility of one-step endoscopic metal stenting for distal malignant biliary obstruction [J].
Shimizu, Shuya ;
Naitoh, Itaru ;
Nakazawa, Takahiro ;
Hayashi, Kazuki ;
Miyabe, Katsuyuki ;
Kondo, Hiromu ;
Yoshida, Michihiro ;
Yamashita, Hiroaki ;
Ohara, Hirotaka ;
Joh, Takashi .
JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2014, 21 (03) :219-225
[26]   Long-term outcomes of endoscopic double stenting using an anti-reflux metal stent for combined malignant biliary and duodenal obstruction [J].
Sasaki, Takashi ;
Takeda, Tsuyoshi ;
Yamada, Yuto ;
Okamoto, Takeshi ;
Mori, Chinatsu ;
Mie, Takafumi ;
Kasuga, Akiyoshi ;
Matsuyama, Masato ;
Ozaka, Masato ;
Sasahira, Naoki .
JOURNAL OF HEPATO-BILIARY-PANCREATIC SCIENCES, 2023, 30 (01) :144-152
[27]   Percutaneous transpapillary biliary stent placement for distal malignant biliary obstruction: Outcomes and survival analysis [J].
Zu, Qing-Quan ;
Zhang, Jin-Xing ;
Wang, Bin ;
Ye, Wei ;
Liu, Sheng ;
Shi, Hai-Bin .
TURKISH JOURNAL OF GASTROENTEROLOGY, 2019, 30 (08) :714-+
[28]   Metallic stent with high axial force as a risk factor for cholecystitis in distal malignant biliary obstruction [J].
Nakai, Yousuke ;
Isayama, Hiroyuki ;
Kawakubo, Kazumichi ;
Kogure, Hirofumi ;
Hamada, Tsuyoshi ;
Togawa, Osamu ;
Ito, Yukiko ;
Matsubara, Saburo ;
Arizumi, Toshihiko ;
Yagioka, Hiroshi ;
Takahara, Naminatsu ;
Uchino, Rie ;
Mizuno, Suguru ;
Miyabayashi, Koji ;
Yamamoto, Keisuke ;
Sasaki, Takashi ;
Yamamoto, Natsuyo ;
Hirano, Kenji ;
Tada, Minoru ;
Koike, Kazuhiko .
JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2014, 29 (07) :1557-1562
[29]   The Role of Lumen Apposing Metal Stents in the Palliation of Distal Malignant Biliary Distal Obstruction [J].
Voiosu, Theodor Alexandru ;
Rimbas, Mihai ;
Larghi, Alberto .
CANCERS, 2023, 15 (10)
[30]   Palliation of Distal Malignant Biliary Obstruction: A Selective Approach [J].
Yeung, Y. P. ;
Yip, A. W. C. .
INTERNATIONAL SURGERY, 2009, 94 (01) :67-73