Improved Performance of PET Myocardial Perfusion Imaging Compared to SPECT in the Evaluation of Suspected CAD

被引:7
|
作者
Alam, Loba [1 ,2 ]
Omar, Alaa Mabrouk Salem [1 ,2 ]
Patel, Krishna K. K. [1 ,3 ]
机构
[1] Mt Sinai Morningside, Dept Cardiol, New York, NY 10025 USA
[2] Icahn Sch Med Mt Sinai, New York, NY USA
[3] Icahn Sch Med Mt Sinai, Dept Populat Hlth Sci & Policy, New York, NY 10029 USA
关键词
Positron emission tomography; Myocardial perfusion imaging; Myocardial blood flow; Coronary artery disease; Microvascular disease; Single photon emission computed tomography; CORONARY-ARTERY-DISEASE; POSITRON-EMISSION-TOMOGRAPHY; IMPAIRED CHRONOTROPIC RESPONSE; TREADMILL EXERCISE SCORE; SYSTOLIC BLOOD-PRESSURE; ALL-CAUSE MORTALITY; PROGNOSTIC VALUE; FLOW RESERVE; MICROVASCULAR DYSFUNCTION; SURVIVAL BENEFIT;
D O I
10.1007/s11886-023-01851-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose of ReviewMyocardial perfusion imaging (MPI) with single photon emission computed tomography (SPECT) has played a central role in the non-invasive evaluation of patients with obstructive coronary artery disease (CAD) for decades. In this review, we discuss the key differences and advantages of positron emission tomography (PET) MPI over SPECT MPI as it relates to the diagnosis, prognosis, as well as clinical decision-making in patients with suspected CAD.Recent FindingsStress-induced perfusion abnormalities on SPECT help estimate presence, extent, and location of ischemia and flow-limiting obstructive CAD, help with risk stratification, and serve as a gatekeeper to identify patients who will benefit from downstream revascularization versus medical management. Some of the major limitations of SPECT include soft-tissue attenuation artifacts, underestimation of ischemia due to reliance on relative perfusion assessment, and longer protocols with higher radiation dose when performed with traditional equipment. PET MPI addresses most of these limitations and offers better quality images, higher diagnostic accuracy along with shorter protocols and lower radiation dose to the patient. A special advantage of PET scanning lies in the ability to quantify absolute myocardial blood flow and assess true extent of epicardial involvement along with identifying non-obstructive phenotypes of CAD such as diffuse atherosclerosis and microvascular dysfunction. In addition, stress acquisition at/near peak stress with PET allows us to measure left ventricular ejection fraction reserve and myocardial blood flow reserve, which help with identifying patients at a higher risk of future cardiac events and optimally select candidates for revascularization.The several technical advantages of PET MPI position as a superior method to diagnose obstructive and non-obstructive phenotypes of ischemic heart disease affecting the entirety of the coronary circulation offer incremental value for risk stratification and guide post-test management strategy for patients with suspected CAD.
引用
收藏
页码:281 / 293
页数:13
相关论文
共 50 条
  • [21] Improved myocardial perfusion PET imaging using artificial neural networks
    Wang, Xinhui
    Yang, Bao
    Moody, Jonathan B.
    Tang, Jing
    PHYSICS IN MEDICINE AND BIOLOGY, 2020, 65 (14)
  • [22] EANM procedural guidelines for PET/CT quantitative myocardial perfusion imaging
    Sciagra, Roberto
    Lubberink, Mark
    Hyafil, Fabien
    Saraste, Antti
    Slart, Riemer H. J. A.
    Agostini, Denis
    Nappi, Carmela
    Georgoulias, Panagiotis
    Bucerius, Jan
    Rischpler, Christoph
    Verberne, Hein J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (04) : 1040 - 1069
  • [23] Static CT myocardial perfusion imaging: image quality, artifacts including distribution and diagnostic performance compared to 82Rb PET
    Inacio, Joao R.
    Srinivasan, Sriraag Balaji
    Ruddy, Terrence D.
    DeKemp, Robert A.
    Rybicki, Frank
    Beanlands, Rob S.
    Chow, Benjamin J. W.
    Dwivedi, Girish
    EUROPEAN JOURNAL OF HYBRID IMAGING, 2022, 6 (01):
  • [24] Recent advances in cardiac PET and PET/CT myocardial perfusion imaging
    Heller, Gary V.
    Calnon, Dennis
    Dorbala, Sharmila
    JOURNAL OF NUCLEAR CARDIOLOGY, 2009, 16 (06) : 962 - 969
  • [25] Myocardial perfusion imaging agents: SPECT and PET
    George A. Beller
    Steven R. Bergmann
    Journal of Nuclear Cardiology, 2004, 11 : 71 - 86
  • [26] Quantification of Myocardial Perfusion Reserve Using Dynamic SPECT Imaging in Humans: A Feasibility Study
    Ben-Haim, Simona
    Murthy, Venkatesh L.
    Breault, Christopher
    Allie, Rayjanah
    Sitek, Arkadiusz
    Roth, Nathaniel
    Fantony, Jolene
    Moore, Stephen C.
    Park, Mi-Ae
    Kijewski, Marie
    Haroon, Athar
    Slomka, Piotr
    Erlandsson, Kjell
    Baavour, Rafael
    Zilberstien, Yoel
    Bomanji, Jamshed
    Di Carli, Marcelo F.
    JOURNAL OF NUCLEAR MEDICINE, 2013, 54 (06) : 873 - 879
  • [27] MYOCARDIAL PERFUSION IMAGING WITH PET
    SCHWAIGER, M
    JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (04) : 693 - 698
  • [28] Prognostic value of coronary flow reserve in patients with suspected or known coronary artery disease referred to PET myocardial perfusion imaging: A meta-analysis
    Green, Roberta
    Cantoni, Valeria
    Acampa, Wanda
    Assante, Roberta
    Zampella, Emilia
    Nappi, Carmela
    Gaudieri, Valeria
    Mannarino, Teresa
    Cuocolo, Renato
    Petretta, Mario
    Cuocolo, Alberto
    JOURNAL OF NUCLEAR CARDIOLOGY, 2021, 28 (03) : 904 - 918
  • [29] SPECT Versus PET Myocardial Perfusion Imaging in Patients with Equivocal CT
    Vasvi Singh
    Marcelo F. Di Carli
    Current Cardiology Reports, 2020, 22
  • [30] Diagnostic performance of PET, SPECT and CMR perfusion imaging for the detection of significant coronary artery disease - a meta-analysis
    Caroline Jaarsma
    Tim Leiner
    Sebastiaan Bekkers
    Harry Crijns
    Joachim Wildberger
    Eike Nagel
    Patricia Nelemans
    Simon Schalla
    Journal of Cardiovascular Magnetic Resonance, 13 (Suppl 1)