关键词
Inter-story isolation; Elastomeric bearings; Segmental buildings; Drift ratio; High-rise buildings; Numerical simulations; OpenSees; TUNED-MASS DAMPERS; ROOF ISOLATION SYSTEM; HORIZONTAL BEHAVIOR; AXIAL LOADS; MODEL; PERFORMANCE; STRENGTH; DESIGN; BASE;
D O I
10.1016/j.engstruct.2022.115175
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Inter-story seismic isolation has become a valuable solution for high-rise buildings to effectively separate the various parts having several functions, and thus different seismic performance requirements, with the main advantage being the interruption of the flux of energy between the upper and lower stories. The isolation layers that are introduced at various heights of the buildings may filter the inertial forces transmitted to the super-structure and improve the seismic behavior of the whole system. This paper studies a 20-floor building and several inter-story configurations where the isolation layer is located at several heights, in order to discuss the performances of each model and to assess the best location along the height of the structure. OpenSees is employed to calculate the high non-linearities of the models and to consider the interaction between the vertical loads and the horizontal forces. The various responses are discussed in terms of shear forces, accelerations and drifts, demonstrating the potentialities of inter-story isolation as a means of base isolation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Investigation of the seismic response of high-rise buildings supported on tension-resistant elastomeric isolation bearings
    Lu, Xilin
    Wang, Dong
    Wang, Shanshan
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2016, 45 (13) : 2207 - 2228
  • [23] The design of inter-story isolated buildings built on top of metro depots
    Xie L.-L.
    Wang X.-Y.
    Li A.-Q.
    Miao Q.-S.
    Ge D.-D.
    Sun H.-L.
    Gongcheng Lixue/Engineering Mechanics, 2022, 39 (07): : 39 - 48
  • [24] Seismic analysis of high-rise mega-braced frame-core buildings
    Brunesi, E.
    Nascimbene, R.
    Casagrande, L.
    ENGINEERING STRUCTURES, 2016, 115 : 1 - 17
  • [25] Study on seismic performance of inter-story isolation structure with shape memory alloy friction pendulum bearings
    Xian Z.
    Tan P.
    Zheng W.
    Chen H.
    Liu Y.
    Yang K.
    Jianzhu Jiegou Xuebao/Journal of Building Structures, 2024, 45 (08): : 141 - 153
  • [26] Toward multivariate fragility functions for seismic damage and loss estimation of high-rise buildings
    Kourehpaz, Pouria
    Molina Hutt, Carlos
    Lallemant, David
    EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2023, 52 (13) : 4164 - 4182
  • [27] Insights into inter-story isolation design through the analysis of two case studies
    Faiella, Diana
    Mele, Elena
    ENGINEERING STRUCTURES, 2020, 215
  • [28] Analysis Methods of Irregular High-Rise Buildings Subjected to Seismic Loads
    Intekhab, Md Shahzar
    Das, Swagato
    Jajnery, M. Ahmad
    Akhtar, Salman
    Sahoo, Debarshi
    Saha, Purnachandra
    JOURNAL OF VIBRATION ENGINEERING & TECHNOLOGIES, 2023, 11 (03) : 1359 - 1382
  • [29] Seismic assessment of high-rise buildings through dynamic nonlinear analysis
    Wu, Xiuwen
    Lin, Daoyun
    ANNALS OF GEOPHYSICS, 2022, 65
  • [30] Mitigation of seismic risk on high-rise buildings using rocking cores
    Mollaioli, F.
    Angelucci, G.
    De Angelis, M.
    STRUCTURES AND ARCHITECTURE: A VIABLE URBAN PERSPECTIVE?, 2022, 2 : 1203 - 1210