Three-dimensional, 2.5-minute, 7T phosphorus magnetic resonance spectroscopic imaging of the human heart using concentric rings

被引:10
作者
Clarke, William T. [1 ]
Hingerl, Lukas [2 ]
Strasser, Bernhard [2 ]
Bogner, Wolfgang [2 ]
Valkovic, Ladislav [3 ,4 ]
Rodgers, Christopher T. [3 ,5 ]
机构
[1] Univ Oxford, Wellcome Ctr Integrat Neuroimaging, Nuffield Dept Clin Neurosci, FMRIB, Oxford, England
[2] Med Univ Vienna, High Field MR Ctr, Dept Biomed Imaging & Image Guided Therapy, Vienna, Austria
[3] Univ Oxford, Oxford Ctr Clin Magnet Resonance Res, Radcliffe Dept Med, Oxford, England
[4] Slovak Acad Sci, Inst Measurement Sci, Dept Imaging Methods, Bratislava, Slovakia
[5] Univ Cambridge, Wolfson Brain Imaging Ctr, Dept Clin Neurosci, Cambridge, England
基金
英国惠康基金; 奥地利科学基金会;
关键词
P-31; CRT; heart; MRSI; phosphorus; spectroscopy; CREATINE-KINASE; ACCURATE;
D O I
10.1002/nbm.4813
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A three-dimensional (3D), density-weighted, concentric rings trajectory (CRT) magnetic resonance spectroscopic imaging (MRSI) sequence is implemented for cardiac phosphorus (P-31)-MRS at 7 T. The point-by-point k-space sampling of traditional phase-encoded chemical shift imaging (CSI) sequences severely restricts the minimum scan time at higher spatial resolutions. Our proposed CRT sequence implements a stack of concentric rings, with a variable number of rings and planes spaced to optimise the density of k-space weighting. This creates flexibility in acquisition time, allowing acquisitions substantially faster than traditional phase-encoded CSI sequences, while retaining high signal-to-noise ratio (SNR). We first characterise the SNR and point-spread function of the CRT sequence in phantoms. We then evaluate it at five different acquisition times and spatial resolutions in the hearts of five healthy participants at 7 T. These different sequence durations are compared with existing published 3D acquisition-weighted CSI sequences with matched acquisition times and spatial resolutions. To minimise the effect of noise on the short acquisitions, low-rank denoising of the spatiotemporal data was also performed after acquisition. The proposed sequence measures 3D localised phosphocreatine to adenosine triphosphate (PCr/ATP) ratios of the human myocardium in 2.5 min, 2.6 times faster than the minimum scan time for acquisition-weighted phase-encoded CSI. Alternatively, in the same scan time, a 1.7-times smaller nominal voxel volume can be achieved. Low-rank denoising reduced the variance of measured PCr/ATP ratios by 11% across all protocols. The faster acquisitions permitted by 7-T CRT P-31-MRSI could make cardiac stress protocols or creatine kinase rate measurements (which involve repeated scans) more tolerable for patients without sacrificing spatial resolution.
引用
收藏
页数:14
相关论文
共 37 条
[31]   Measuring inorganic phosphate and intracellular pH in the healthy and hypertrophic cardiomyopathy hearts by in vivo 7T 31P-cardiovascular magnetic resonance spectroscopy [J].
Valkovic, Ladislav ;
Clarke, William T. ;
Schmid, Albrecht I. ;
Raman, Betty ;
Ellis, Jane ;
Watkins, Hugh ;
Robson, Matthew D. ;
Neubauer, Stefan ;
Rodgers, Christopher T. .
JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2019, 21 (1)
[32]   Improved method for accurate and efficient quantification of MRS data with use of prior knowledge [J].
Vanhamme, L ;
van den Boogaart, A ;
Van Huffel, S .
JOURNAL OF MAGNETIC RESONANCE, 1997, 129 (01) :35-43
[33]   Denoising of diffusion MRI using random matrix theory [J].
Veraart, Jelle ;
Novikov, Dmitry S. ;
Christiaens, Daan ;
Ades-Aron, Benjamin ;
Sijbers, Jan ;
Fieremans, Els .
NEUROIMAGE, 2016, 142 :384-396
[34]  
Wampl S., 2020, P INT SOC MAG RESON, V28, P0487
[35]   Investigating the effect of trigger delay on cardiac 31P MRS signals [J].
Wampl, Stefan ;
Koerner, Tito ;
Valkovic, Ladislav ;
Trattnig, Siegfried ;
Wolzt, Michael ;
Meyerspeer, Martin ;
Schmid, Albrecht Ingo .
SCIENTIFIC REPORTS, 2021, 11 (01)
[36]   ATP flux through creatine kinase in the normal, stressed, and failing human heart [J].
Weiss, RG ;
Gerstenblith, G ;
Bottomley, PA .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2005, 102 (03) :808-813
[37]   MRI using a concentric rings trajectory [J].
Wu, Hochong H. ;
Lee, Jin Hyung ;
Nishimura, Dwight G. .
MAGNETIC RESONANCE IN MEDICINE, 2008, 59 (01) :102-112