Effects of circumferential fin on cooling performance improvement of forced air-cooled battery pack

被引:11
|
作者
Padalkar, Akshay B. [1 ]
Chaudhari, Mangesh B. [1 ,2 ]
Kore, Kiran B. [3 ]
Newaskar, Shivkumar R. [3 ]
Nilegave, Dhanaraj S. [3 ,4 ]
Funde, Adinath M. [3 ]
机构
[1] Savitribai Phule Pune Univ, Dept Technol, Pune 411007, Maharashtra, India
[2] Vishwakarma Inst Technol, Dept Mech Engn, Pune 411037, Maharashtra, India
[3] Savitribai Phule Pune Univ, Ctr Energy Studies, Sch Energy Studies, Pune 411007, India
[4] BK Birla Coll, Dept Phys, Kalyan 421304, India
关键词
Battery thermal management; Battery Cooling performance; Design of battery; Cooling efficiency factor; LITHIUM-ION BATTERY; THERMAL MANAGEMENT-SYSTEM; CONVECTION; DISCHARGE; ISSUES; MODELS; STATE;
D O I
10.1016/j.applthermaleng.2023.122013
中图分类号
O414.1 [热力学];
学科分类号
摘要
In demand for clean energy sources, batteries have a vital role to play. Batteries are the heart of many electrical energy storage systems, as in electric vehicles (EVs). The high internal heat generation from a battery is the main hindrance to battery performance and safety. The high-temperature environment impacts performance; therefore, maintaining the battery temperature within desired limits is essential. In this work, we focus on the increasing effectivity of forced air cooling for high-capacity batteries at high discharge rates, decreasing auxiliary power consumption without compromising the compactness of the battery pack. The novelty of this work is that we have developed a hybrid BTMS consisting of circumferential fins and forced air cooling. Using a circumferential fin clad to the cell body has the advantage of increasing the surface area of the battery pack so that the ability of air to extract heat from the battery pack is improved and the auxiliary power consumption is reduced. The experiments use thin circumferential fins of 0.5 mm thickness mounted on cell bodies and discharged at various rates. The numerical model has been developed and tested using ANSYS FLUENT software. Using a single circumferential fin (Model 1) improves cooling performance by 3.14 %, and using three circumferential fins (Model 2) improves cooling performance by 7.32 % in the natural convection mode compared to the uncooled model. The improvement achieved in forced air cooling with a velocity of 2 m/s and three circumferential fins cooling performance is improved by 18.71 %. It is observed that using fins, the overall increase in weight of the system is by 3.58 %.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Study on The Cooling Performance By Cooling Air Channel Design For Air-Cooled Hev Battery Pack
    Lee, Geon Hui
    Yeom, Dae Yeon
    Kim, Geon Ho
    Jang, Siyoul
    INTERNATIONAL JOURNAL OF AUTOMOTIVE TECHNOLOGY, 2025, 26 (02) : 415 - 435
  • [2] Design of the structure of battery pack in parallel air-cooled battery thermal management system for cooling efficiency improvement
    Chen, Kai
    Song, Mengxuan
    Wei, Wei
    Wang, Shuangfeng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2019, 132 : 309 - 321
  • [3] Research on heat dissipation performance and flow characteristics of air-cooled battery pack
    Xu, Xiao Ming
    Sun, Xu Dong
    Hu, Dong Hai
    Li, Ren Zheng
    Tang, Wei
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2018, 42 (11) : 3658 - 3671
  • [4] Cooling performance optimization of air-cooled battery thermal management system
    Wang, Meiwei
    Teng, Shiyang
    Xi, Huan
    Li, Yuquan
    APPLIED THERMAL ENGINEERING, 2021, 195
  • [5] Research on the heat dissipation performance of battery pack based on forced air cooling
    Xu, X. M.
    He, R.
    JOURNAL OF POWER SOURCES, 2013, 240 : 33 - 41
  • [6] Improved energy performance of air-cooled chiller system with mist pre-cooling Mist improvement on air-cooled chillers
    Yu, F. W.
    Chan, K. T.
    APPLIED THERMAL ENGINEERING, 2011, 31 (04) : 537 - 544
  • [7] Shortcut computation for the thermal management of a large air-cooled battery pack
    Liu, Zhongming
    Wang, Yuxin
    Zhang, Jun
    Liu, Zhibin
    APPLIED THERMAL ENGINEERING, 2014, 66 (1-2) : 445 - 452
  • [8] Evaporative cooling technologies for air-cooled chillers for building energy performance improvement
    Yu, F. W.
    Chan, K. T.
    Yang, J.
    Sit, R. K. Y.
    ADVANCES IN BUILDING ENERGY RESEARCH, 2016, 10 (01) : 10 - 19
  • [9] Thermal performance investigation of an air-cooled lithium-ion battery pack considering the inconsistency of battery cells
    Peng, Xiongbin
    Ma, Chong
    Garg, Akhil
    Bao, Nengsheng
    Liao, Xiangping
    APPLIED THERMAL ENGINEERING, 2019, 153 : 596 - 603
  • [10] Performance measurements of a forced convection air-cooled rack
    Hwang, Y
    Radermacher, R
    Spinazzola, S
    Menachery, Z
    ITHERM 2004, VOL 1, 2004, : 194 - 198