Estimating the skin dose near to the applicator and acute toxicity in breast cancer patients: An intraoperative electron radiotherapy technique

被引:0
作者
Mirkazemi, Maryam Sadat [1 ]
Mahdavi, Seyed Rabi [2 ]
Nafissi, Nahid [3 ]
Monfared, Ali Shabestani [4 ]
Ghoreishi, Seyedeh Masoumeh [5 ]
Gorji, Kourosh Ebrahimnejad [1 ]
机构
[1] Babol Univ Med Sci, Dept Med Phys, Tehran, Iran
[2] Iran Univ Med Sci, Dept Med Phys, Tehran, Iran
[3] Iran Univ Med Sci, Sch Med, Dept Surg, Tehran, Iran
[4] Babol Univ Med Sci, Hlth Res Inst, Canc Res Ctr, Babol, Iran
[5] Babol Univ Med Sci, Hlth Res Inst, Cellular & Mol Biol Res Ctr, Babol, Iran
关键词
Acute toxicity; applicator; breast cancer; intraoperative electron radiotherapy; skin dose; RADIATION-THERAPY; DOSIMETRY; SEROMA; IOERT;
D O I
10.4103/jcrt.jcrt_898_21
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Introduction: Intraoperative electron radiation therapy (IOERT) is one of the most recently popular therapeutic methods for breast cancer. This study aimed to measure the skin dose near the applicator during IOERT of breast cancer patients, as well as, the incidence of acute toxicity after surgery. Materials and Methods: Thirty-six female patients participated in the current study with the prescribed dose of 21 and 12 Gy for IOERT as full and boost, respectively. The skin dose was investigated based on different applicator sizes, tumor bed thicknesses, and monitor units (MUs). The energy was chosen 8 MeV, and EBT3 film was used for the dosimetric process. In addition, the acute toxicity included healing time for the surgical wound, scaling of the skin, itching, necrosis, redness as well as seroma formation for 1 week and 1 month were recorded. The results were compared to those of 22 patients who underwent the surgery without IOERT. Results: The highest skin dose for the patients was obtained 2.09 Gy, which is lower than the threshold dose (6 Gy). Furthermore, the findings showed that the average skin dose was higher in bigger applicator sizes and MU and lower tumor bed thicknesses. The average of wound healing for the patient underwent IOERT and without the use of IOERT (as the control group) was 19.32 and 11.67 days, respectively. One month after surgery, the volume of aspirated seroma was higher in the patients who performed IOERT compared to the control group (250 ml vs. 200 ml). It is notable that there were not observed any redness, itching, scaling, and necrosis in both investigated groups. Conclusion: Owing to the results, the skin dose during IOERT was lower than the recommended level. The dose of IOERT as a full was higher than boost which can be related to the lower number of the patients in full method; however, there was a well-tolerated without severe acute complication, especially seroma formation and wound healing time in both full and boost methods.
引用
收藏
页码:650 / 656
页数:7
相关论文
共 30 条
[1]   Surface dose measurement with Gafchromic EBT3 film for intensity modulated radiotherapy technique [J].
Akbas, Ugur ;
Kesen, Nazmiye Donmez ;
Koksal, Canan ;
Okutan, Murat ;
Demir, Bayram ;
Becerir, Hatice Bilge .
3RD INTERNATIONAL CONFERENCE ON THEORETICAL AND EXPERIMENTAL STUDIES IN NUCLEAR APPLICATIONS AND TECHNOLOGY (TESNAT 2017), 2017, 154
[2]   Awareness and current knowledge of breast cancer [J].
Akram, Muhammad ;
Iqbal, Mehwish ;
Daniyal, Muhammad ;
Khan, Asmat Ullah .
BIOLOGICAL RESEARCH, 2017, 50
[3]   Wound Healing and Cancer Stem Cells: Inflammation as a Driver of Treatment Resistance in Breast Cancer [J].
Arnold, Kimberly M. ;
Opdenaker, Lynn M. ;
Flynn, Daniel ;
Sims-Mourtada, Jennifer .
CANCER GROWTH AND METASTASIS, 2015, 8 :1-13
[4]   Evaluation of Dose Rate and Photon Energy Dependence of Gafchromic EBT3 Film Irradiating with 6 MV and Co-60 Photon Beams [J].
Ataei, Gholamreza ;
Rezaei, Maral ;
Gorji, Ebrahimnejad ;
Banaei, Amin ;
Goushbolagh, Nouraddin Abdi ;
Farhood, Bagher ;
Bagheri, Mahmoud ;
Firouzjah, Razzagh Abedi .
JOURNAL OF MEDICAL SIGNALS & SENSORS, 2019, 9 (03) :204-210
[5]   Electron radiotherapy (IOERT) for applications outside of the breast: Dosimetry and influence of tissue inhomogeneities [J].
Avanzo, Michele ;
Dassie, Andrea ;
Acharya, Prabhu Chandra ;
Chiovati, Paola ;
Pirrone, Giovanni ;
Avigo, Cinzia ;
Barresi, Loredana ;
Soai Dang Quoc ;
Fiagbedzi, Emmanuel ;
Navarria, Federico ;
Palazzari, Elisa ;
Bertola, Giulio ;
De Paoli, Antonino ;
Stancanello, Joseph ;
Sartor, Giovanna .
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 69 :82-89
[6]   Measurement of the photon and thermal neutron doses of contralateral breast surface in breast cancer radiotherapy [J].
Bagheri, Hamed ;
Firouzjah, Razzagh Abedi ;
Farhood, Bagher .
JOURNAL OF RADIOTHERAPY IN PRACTICE, 2020, 19 (03) :226-232
[7]   In vivo dosimetry using Gafchromic films during pelvic intraoperative electron radiation therapy (IOERT) [J].
Costa, Filipa ;
Sarmento, Sandra ;
Gomes, Dora ;
Magalhaes, Helena ;
Arrais, Rosario ;
Moreira, Graciete ;
Cruz, Maria Fatima ;
Silva, Jose Pedro ;
Santos, Lucio ;
Sousa, Olga .
BRITISH JOURNAL OF RADIOLOGY, 2016, 89 (1063)
[8]  
Dutta SW, 2017, BREAST CANCER-TARGET, V9, P257, DOI 10.2147/BCTT.S112516
[9]   The accuracy of EGSnrc, Geant4 and PENELOPE Monte Carlo systems for the simulation of electron scatter in external beam radiotherapy [J].
Faddegon, Bruce A. ;
Kawrakow, Iwan ;
Kubyshin, Yuri ;
Perl, Joseph ;
Sempau, Josep ;
Urban, Laszlo .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (20) :6151-6163
[10]  
Fastner G, 2016, STRAHLENTHER ONKOL, V192, P1, DOI 10.1007/s00066-015-0895-2