Acoustic injection method based on weak echo signals for leak detection and localization in gas pipelines

被引:5
|
作者
Yan, Zhaoli [1 ]
Cui, Xiwang [2 ]
Gao, Yan [1 ]
机构
[1] Chinese Acad Sci, Inst Acoust, Key Lab Noise & Vibrat Res, Beijing 100190, Peoples R China
[2] Beijing Informat Sci & Technol Univ, Sch Instrument Sci & Optoelect Engn, Beijing 100192, Peoples R China
基金
中国国家自然科学基金;
关键词
Leak detection; Leak localization; Acoustic injection; Gas pipelines; NOISE; WAVE; EXCITATION; LOCATION;
D O I
10.1016/j.apacoust.2023.109577
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Underground gas pipelines are facing health and safety issues due to the material corrosion and equipment aging. Conventional acoustic methods may fail to detect and localize leaks in low and medium pressure gas pipelines because the sound of gas escaping from a leak source is usually too weak to be detected. In this paper, an active acoustic injection method is presented to stimulate specific frequency sound waves into the pipeline for leak detection based on weak echoes from the leak location. Further analysis is conducted on the relationships between the reflection coefficient and the size of the leak hole, the pipe diameter, the wall thickness of the pipe and the sound frequency. A signal reconstruction method is subsequently proposed to effectively detect and localize the echo signals. Finally, some experiments are carried out in a specially constructed gas pipe. Field test results indicate that a leak localization accuracy of 0.1 m can be achieved by the proposed method, which may be beneficial to practical leakage detection in gas pipelines.
引用
收藏
页数:10
相关论文
共 50 条
  • [41] An acoustic leak-detection tool for water pipelines
    Tscheliesnig, P
    McNulty, JG
    1ST INTERNATIONAL CONFERENCE ON PROTECTING THE ENVIRONMENT - IN PROCESS INDUSTRY, 1998, (30): : 53 - 61
  • [42] Piezoelectric structural acoustic leak detection for pressurized pipelines
    Pretorius, JV
    Van Shoor, MC
    Muller, GJ
    Jessiman, AW
    Smart Structures and Materials 2005: Industrial and Commercial Applications of Smart Structures Technologies, 2005, 5762 : 212 - 223
  • [43] Leak localization in industrial-fluid pipelines based on acoustic emission burst monitoring
    Thang Bui Quy
    Kim, Jong-Myon
    MEASUREMENT, 2020, 151
  • [44] Leak detection and localization of main methane drainage pipelines
    Zhou, Song
    Jiang, Shuguang
    Wang, Kai
    Zhao, Honghong
    Wang, Yanheng
    Tao, Weiyong
    Yu, Bin
    Electronic Journal of Geotechnical Engineering, 2015, 20 (07): : 1999 - 2018
  • [45] A review of leak detection methods based on pressure waves in gas pipelines
    Zhao, Linkun
    Cao, Zheng
    Deng, Jianqiang
    MEASUREMENT, 2024, 236
  • [46] Leak detection in gas pipelines using wavelet-based filtering
    Urbanek, J.
    Barszcz, T.
    Uhl, T.
    Staszewski, W. J.
    Beck, S. B. M.
    Schmidt, B.
    STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2012, 11 (04): : 405 - 412
  • [47] Leak detection in a gas pipeline using spectral portrait of acoustic emission signals
    Thang Bui Quy
    Kim, Jong-Myon
    MEASUREMENT, 2020, 152
  • [48] Leak Detection and Localization of Gas Pipeline System Based on Full Dynamical Model Method
    Chai Senchun
    Dong Lijing
    Zhang Baihai
    Chai Xiangyun
    2011 30TH CHINESE CONTROL CONFERENCE (CCC), 2011, : 5894 - 5898
  • [49] Leak detection in pipelines based on PCA
    Hu, R
    Ye, H
    Wang, GZ
    Lu, C
    2004 8TH INTERNATIONAL CONFERENCE ON CONTROL, AUTOMATION, ROBOTICS AND VISION, VOLS 1-3, 2004, : 1985 - 1989
  • [50] Vacuum leak detection based on acoustic emission method
    Zhang, Tao
    Zeng, Zhou-Mo
    Li, Yi-Bo
    Meng, Dong-Hui
    Wang, Wei-Kui
    Bian, Xu
    Qi, Lei
    Jin, Shi-Jiu
    Zhendong yu Chongji/Journal of Vibration and Shock, 2013, 32 (24): : 164 - 168