Estimating size specific dose estimate from computed tomography radiograph localizer with radiation risk assessment

被引:1
|
作者
Burton, Christiane Sarah [1 ]
Al-Ward, Shahad [2 ]
机构
[1] St Jude Childrens Res Hosp, Dept Diagnost Imaging, Memphis, TN 38105 USA
[2] St Jude Childrens Res Hosp, Dept Radiat Oncol, Memphis, TN USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 06期
关键词
CT; localizer; SSDE; water-equivalent diameter; BODY CT; ABDOMEN;
D O I
10.1002/acm2.13989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuantifying radiation burden is necessary for optimizing imaging protocols. The normalized dose coefficient (NDC) is determined from the water-equivalent diameter (WED) and is used to scale the CTDIvol based on body habitus to determine the size specific dose estimate (SSDE). In this study we determine the SSDE prior to the CT scan and how sensitive the SSDE from WED is to the lifetime attributable risk (LAR) from BEIR VII. MethodFor calibration, phantom images are used to relate the mean pixel values along a profile (PPV over bar $\overline {{\rm{PPV}}} $) of the CT localizer to the water-equivalent area (A(W)) of the CT axial scan at the same z-location. Images of the CTDIvol phantoms (32 cm, 16 cm, and similar to 1 cm) and ACR phantom (Gammex 464) were acquired on four scanners. The relationship between the A(W) and PPV over bar $\overline {{\rm{PPV}}} $ was used to calculate the WED from the CT localizer for patient scans. A total of 790 CT examinations of the chest and abdominopelvic regions were used in this study. The effective diameter (ED) was calculated from the CT localizer. The LAR was calculated based on the patient chest and abdomen using the National Cancer Institute Dosimetry System for Computed Tomography (NCICT). The radiation sensitivity index (RSI) and risk differentiability index (RDI) were calculated for SSDE and CTDIvol. ResultsThe WED from CT localizers and CT axials scans show good correlation (R-2 = 0.96) with the maximum percentage difference being 13.45%. The NDC from WED correlates poorly with LAR for lungs (R-2 = 0.18) and stomach (R-2 = 0.19), however that is the best correlation. ConclusionThe SSDE can be determined within 20% as recommended by the report of AAPM TG 220. The CTDIvol and SSDE are not good surrogates for radiation risk, however the sensitivity for SSDE improves when using WED instead of ED.
引用
收藏
页数:9
相关论文
共 50 条
  • [41] Size-specific dose estimates (SSDEs) for computed tomography and influencing factors on it: a systematic review
    Satharasinghe, D. M.
    Jeyasugiththan, J.
    Wanninayake, W. M. N. M. B.
    Pallewatte, A. S.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2021, 41 (04) : R108 - R124
  • [42] Radiation dose in chest CT: Assessment of size-specific dose estimates based on water-equivalent correction
    Gabusi, M.
    Riccardi, L.
    Aliberti, C.
    Vio, S.
    Paiusco, M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (02): : 393 - 397
  • [43] Radiation Dose from Computed Tomography Scans for Korean Pediatric and Adult Patients
    Won, Tristan
    Lee, Ae-Kyoung
    Choi, Hyung-do
    Lee, Choonsik
    JOURNAL OF RADIATION PROTECTION AND RESEARCH, 2021, 46 (03): : 98 - 105
  • [44] Estimation of radiation dose associated with bone SPECT/CT and establishing local diagnostic reference levels using size-specific dose estimate
    Alrehily, Faisal
    Alshamrani, Abdullah F.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2023, 16 (01)
  • [45] Radiation risk from chest, abdomen and pelvis computed tomography investigations
    Alkhorayef, M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2018, 318 (01) : 661 - 665
  • [46] CAN THE SIZE-SPECIFIC DOSE ESTIMATE BE DERIVED FROM THE BODY MASS INDEX? A FEASIBILITY STUDY
    Steiniger, Beatrice
    Klippel, Chris
    Teichgraeber, Ulf
    Reichenbach, Juergen R.
    Fiebich, Martin
    RADIATION PROTECTION DOSIMETRY, 2022, 198 (06) : 325 - 333
  • [47] Radiation dose assessment in multiple injured patients using whole-body computed tomography
    Abuzaid, Mohamed M.
    Tekin, H. O.
    Elshami, W.
    Almisned, Ghada
    Ene, Antoaneta
    Zakaly, Hesham M. H.
    JOURNAL OF RADIATION RESEARCH AND APPLIED SCIENCES, 2022, 15 (04)
  • [48] Personalized Dose Reduction for Computed Tomography Scanning: Size Matters, so Does Prior Radiation Exposures
    Kalra, Mannudeep K.
    Francis, Isaac R.
    CLINICAL GASTROENTEROLOGY AND HEPATOLOGY, 2010, 8 (03) : 231 - 232
  • [49] Radiation Dose Associated With Common Computed Tomography Examinations and the Associated Lifetime Attributable Risk of Cancer
    Smith-Bindman, Rebecca
    Lipson, Jafi
    Marcus, Ralph
    Kim, Kwang-Pyo
    Mahesh, Mahadevappa
    Gould, Robert
    de Gonzalez, Amy Berrington
    Miglioretti, Diana L.
    ARCHIVES OF INTERNAL MEDICINE, 2009, 169 (22) : 2078 - 2086
  • [50] A Segmentation-based Automated Calculation of Patient Size and Size-specific Dose Estimates in Pediatric Computed Tomography Scans
    Abdulkadir, Muhammad Kabir
    Osman, Noor Diyana
    Achuthan, Anusha
    Nasirudin, Radin A.
    Ahmad, Muhammad Zabidi
    Zain, Noor Hasyima Mat
    Shuaib, Ibrahim Lutfi
    JOURNAL OF MEDICAL PHYSICS, 2024, 49 (03) : 456 - 463