Estimating size specific dose estimate from computed tomography radiograph localizer with radiation risk assessment

被引:1
|
作者
Burton, Christiane Sarah [1 ]
Al-Ward, Shahad [2 ]
机构
[1] St Jude Childrens Res Hosp, Dept Diagnost Imaging, Memphis, TN 38105 USA
[2] St Jude Childrens Res Hosp, Dept Radiat Oncol, Memphis, TN USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 06期
关键词
CT; localizer; SSDE; water-equivalent diameter; BODY CT; ABDOMEN;
D O I
10.1002/acm2.13989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuantifying radiation burden is necessary for optimizing imaging protocols. The normalized dose coefficient (NDC) is determined from the water-equivalent diameter (WED) and is used to scale the CTDIvol based on body habitus to determine the size specific dose estimate (SSDE). In this study we determine the SSDE prior to the CT scan and how sensitive the SSDE from WED is to the lifetime attributable risk (LAR) from BEIR VII. MethodFor calibration, phantom images are used to relate the mean pixel values along a profile (PPV over bar $\overline {{\rm{PPV}}} $) of the CT localizer to the water-equivalent area (A(W)) of the CT axial scan at the same z-location. Images of the CTDIvol phantoms (32 cm, 16 cm, and similar to 1 cm) and ACR phantom (Gammex 464) were acquired on four scanners. The relationship between the A(W) and PPV over bar $\overline {{\rm{PPV}}} $ was used to calculate the WED from the CT localizer for patient scans. A total of 790 CT examinations of the chest and abdominopelvic regions were used in this study. The effective diameter (ED) was calculated from the CT localizer. The LAR was calculated based on the patient chest and abdomen using the National Cancer Institute Dosimetry System for Computed Tomography (NCICT). The radiation sensitivity index (RSI) and risk differentiability index (RDI) were calculated for SSDE and CTDIvol. ResultsThe WED from CT localizers and CT axials scans show good correlation (R-2 = 0.96) with the maximum percentage difference being 13.45%. The NDC from WED correlates poorly with LAR for lungs (R-2 = 0.18) and stomach (R-2 = 0.19), however that is the best correlation. ConclusionThe SSDE can be determined within 20% as recommended by the report of AAPM TG 220. The CTDIvol and SSDE are not good surrogates for radiation risk, however the sensitivity for SSDE improves when using WED instead of ED.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Changing Radiation Dose From Diagnostic Computed Tomography Examinations in Saskatchewan
    Dumaine, Chance S.
    Leswick, David A.
    Fladeland, Derek A.
    Lim, Hyun J.
    Toews, Lori J.
    CANADIAN ASSOCIATION OF RADIOLOGISTS JOURNAL-JOURNAL DE L ASSOCIATION CANADIENNE DES RADIOLOGISTES, 2012, 63 (03): : 183 - 191
  • [32] Imaging dose from cone beam computed tomography in radiation therapy
    Alaei, Parham
    Spezi, Emiliano
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 647 - 658
  • [33] Current utilization and radiation dose from computed tomography in patients with trauma
    Salottolo, Kristin
    Bar-Or, Raphael
    Fleishman, Matthew
    Maruyama, Gen
    Slone, Denetta Sue
    Mains, Charles W.
    Bar-Or, David
    CRITICAL CARE MEDICINE, 2009, 37 (04) : 1336 - 1340
  • [34] Estimating risk of cancer associated with radiation exposure from 64-slice computed tomography coronary angiography
    Einstein, Andrew J.
    Henzlova, Milena J.
    Rajagopalan, Sanjay
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2007, 298 (03): : 317 - 323
  • [35] Establishing local diagnostic reference levels for computed tomography examinations using size-specific dose estimates
    Alrehily, Faisal A.
    Alqahtani, Khalid S.
    Aljohani, Marwan H.
    Alharbi, Nawaf S.
    Alharbi, Reyan M.
    Abdulaal, Osamah M.
    Alshamrani, Abdullah F.
    Alsaedi, Abdulrahman S.
    Al-Murshedi, Sadeq H.
    Alhazmi, Fahad H.
    SAUDI MEDICAL JOURNAL, 2023, 44 (08) : 761 - 766
  • [36] Can Patient's Body Weight Represent Body Diameter for Pediatric Size-Specific Dose Estimate in Thoracic and Abdominal Computed Tomography?
    Kritsaneepaiboon, Supika
    Eng-chuan, Suwadee
    Yoykaew, Saowapark
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2019, 9 : 1 - 8
  • [37] Feasibility of using the computed tomography dose indices to estimate radiation dose to partially and fully irradiated brains in pediatric neuroradiology examinations
    Januzis, Natalie
    Giao Nguyen
    Frush, Donald P.
    Hoang, Jenny K.
    Lowry, Carolyn
    Yoshizumi, Terry T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (14): : 5699 - 5710
  • [38] Radiation dose reduction from low-kilovoltage liver computed tomography using multidetector row computed tomography
    Cho, Pyong-Kon
    RADIATION PROTECTION DOSIMETRY, 2013, 154 (01) : 76 - 80
  • [39] A NOVEL METHOD FOR ESTIMATING PATIENT-SPECIFIC PRIMARY DOSE IN CONE-BEAM COMPUTED TOMOGRAPHY
    Kim, Jinwoo
    Kim, Ho Kyung
    RADIATION PROTECTION DOSIMETRY, 2021, 196 (1-2) : 71 - 84
  • [40] Development of size-specific dose estimates for common computed tomography examinations: a study in Ghana
    Ohene-Botwe, Benard
    Anim-Sampong, Samuel
    Nkansah, Josephine
    JOURNAL OF RADIOLOGICAL PROTECTION, 2023, 43 (01)