Estimating size specific dose estimate from computed tomography radiograph localizer with radiation risk assessment

被引:1
|
作者
Burton, Christiane Sarah [1 ]
Al-Ward, Shahad [2 ]
机构
[1] St Jude Childrens Res Hosp, Dept Diagnost Imaging, Memphis, TN 38105 USA
[2] St Jude Childrens Res Hosp, Dept Radiat Oncol, Memphis, TN USA
来源
JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS | 2023年 / 24卷 / 06期
关键词
CT; localizer; SSDE; water-equivalent diameter; BODY CT; ABDOMEN;
D O I
10.1002/acm2.13989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
BackgroundQuantifying radiation burden is necessary for optimizing imaging protocols. The normalized dose coefficient (NDC) is determined from the water-equivalent diameter (WED) and is used to scale the CTDIvol based on body habitus to determine the size specific dose estimate (SSDE). In this study we determine the SSDE prior to the CT scan and how sensitive the SSDE from WED is to the lifetime attributable risk (LAR) from BEIR VII. MethodFor calibration, phantom images are used to relate the mean pixel values along a profile (PPV over bar $\overline {{\rm{PPV}}} $) of the CT localizer to the water-equivalent area (A(W)) of the CT axial scan at the same z-location. Images of the CTDIvol phantoms (32 cm, 16 cm, and similar to 1 cm) and ACR phantom (Gammex 464) were acquired on four scanners. The relationship between the A(W) and PPV over bar $\overline {{\rm{PPV}}} $ was used to calculate the WED from the CT localizer for patient scans. A total of 790 CT examinations of the chest and abdominopelvic regions were used in this study. The effective diameter (ED) was calculated from the CT localizer. The LAR was calculated based on the patient chest and abdomen using the National Cancer Institute Dosimetry System for Computed Tomography (NCICT). The radiation sensitivity index (RSI) and risk differentiability index (RDI) were calculated for SSDE and CTDIvol. ResultsThe WED from CT localizers and CT axials scans show good correlation (R-2 = 0.96) with the maximum percentage difference being 13.45%. The NDC from WED correlates poorly with LAR for lungs (R-2 = 0.18) and stomach (R-2 = 0.19), however that is the best correlation. ConclusionThe SSDE can be determined within 20% as recommended by the report of AAPM TG 220. The CTDIvol and SSDE are not good surrogates for radiation risk, however the sensitivity for SSDE improves when using WED instead of ED.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Size-Specific Dose Estimate and Effective Dose for Pediatric Computed Tomography
    Khan, Rukhsar
    Shah, Mudasir Ashraf
    Wahab, Shagufta
    Khan, Rizwan Ahmad
    JOURNAL OF MEDICAL PHYSICS, 2025, 50 (01) : 173 - 183
  • [2] Radiation dose of head and abdomen-pelvis computed tomography examinations using size-specific dose estimate
    Ahmadifard, M.
    Bakhshandeh, M.
    Mohammadbeigi, A.
    Khoshgard, K.
    INTERNATIONAL JOURNAL OF RADIATION RESEARCH, 2022, 20 (01): : 185 - 189
  • [3] Correlations Between Body Weight and Size- Specific Dose Estimate on Thoracic Computed Tomography Examination
    Wati, A. L.
    Anam, C.
    Nitasari, A.
    Syarifudin
    Dougherty, G.
    ATOM INDONESIA, 2022, 48 (01) : 61 - 65
  • [4] ACCURACY OF SIZE-SPECIFIC DOSE ESTIMATE CALCULATION FROM CENTER SLICE IN COMPUTED TOMOGRAPHY
    Boos, Johannes
    Kroepil, Patric
    Bethge, Oliver Th.
    Aissa, Joel
    Schleich, Christoph
    Sawicki, Lino Morris
    Heinzler, Niklas
    Antoch, Gerald
    Thomas, Christoph
    RADIATION PROTECTION DOSIMETRY, 2018, 178 (01) : 8 - 19
  • [5] Radiation Dose Reduction for Computed Tomography Localizer Radiography Using an Ag Additional Filter
    Nomura, Keiichi
    Fujii, Keisuke
    Goto, Takahiro
    Tsukagoshi, Shinsuke
    Ota, Hiroyuki
    Iwabuchi, Yuto
    Suzuki, Hidenobu
    Muramatsu, Yoshihisa
    Kobayashi, Tatsushi
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (01) : 84 - 92
  • [6] Effect of table height displacement and patient center deviation on size-specific dose estimates calculated from computed tomography localizer radiographs
    Kuriyama, Kazuki
    Matsubara, Kosuke
    Hisahara, Shu
    Nagata, Yukie
    Nosaka, Rumiko
    Goto, Rika
    Yanano, Nobutaka
    Shimizu, Kanichiro
    Shoji, Tomokazu
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2020, 43 (02) : 665 - 672
  • [7] Novel method of attenuation-based estimating patient size from single CT localizer radiograph
    Lee, Chang-Lae
    Han, Kwanhee
    Cho, Minkook
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2022, 81 (05) : 434 - 440
  • [8] Radiation dose assessment of pediatric computed tomography of the chest: the need to consider patient size
    Dowich, Vanessa
    Torres, Felipe Soares
    Nietto, Andressa Lima
    Timm, Vitor Silva
    Anes, Mauricio
    Bacelar, Alexandre
    Marostica, Paulo Jose Cauduro
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (20) : 2008 - 2013
  • [9] Technical Note: Radiation dose reduction from computed tomography localizer radiographs using a tin spectral shaping filter
    Saltybaeva, Natalia
    Krauss, Andreas
    Alkadhi, Hatem
    MEDICAL PHYSICS, 2019, 46 (02) : 544 - 549
  • [10] Size-specific dose estimates calculated using patient size measurements from scanned projection radiograph in high-resolution chest computed tomography
    Brindhaban, Ajit
    JOURNAL OF MEDICAL RADIATION SCIENCES, 2025, 72 (01) : 85 - 92