Effects of the PCM layer position on the comprehensive performance of a built-middle PV-Trombe wall system for building application in the heating season

被引:42
作者
Ke, Wei [1 ,2 ]
Ji, Jie [1 ,2 ]
Zhang, Chengyan [1 ,2 ]
Xie, Hao [1 ,2 ]
Tang, Yayun [1 ,2 ]
Wang, Chuyao [1 ,2 ]
机构
[1] Univ Sci & Technol China, Dept Thermal Sci & Energy Engn, Hefei 230026, Anhui, Peoples R China
[2] Key Lab Solar Thermal Convers Anhui Prov, Hefei 230026, Anhui, Peoples R China
基金
中国国家自然科学基金;
关键词
Solar energy; BIPV; T; PV-Trombe wall; Phase change material; Comparative analysis; Regional analysis; PHASE-CHANGE MATERIALS; VENETIAN BLIND; THERMAL PERFORMANCE; SIMULATION; VALIDATION; REDUCTION; FACADE; ROOM;
D O I
10.1016/j.energy.2022.126562
中图分类号
O414.1 [热力学];
学科分类号
摘要
Combining phase change materials (PCMs) with building envelope is a promising technology to increase indoor thermal comfort and decrease building energy consumption. However, most existing researches investigated on the PCM layer position in the building envelope only focused on the thermal effects. In this current work, three types of PV-Trombe wall systems with a PCM layer (PCM-PVTW) at different positions were proposed and the coupled impacts on the system's electrical and thermal performance were analyzed compared to the PVTW through numerical analysis based on the electrical and thermal energy outputs trade-off. A comparison case study of these wall systems was conducted under the three full days' ambient conditions in Hefei. Comprehensive performance of these systems in four selected cities in a typical winter week were investigated and the optimal PCM layer position was discussed. Main conclusions are: (1) The PVTW system with a PCM layer attached on the back surface of absorber (APCM-PVTW) achieved the best electrical performance but poorest passive space heating performance; (2) The PCM layer thickness has the greatest impact on the APCM-PVTW; (3) For the colder regions, it's better to place the PCM layer closer to the room side for a better comprehensive benefits.
引用
收藏
页数:23
相关论文
共 52 条
[1]   Performance augmentation of a PV/Trombe wall using Al2O3/Water nano-fluid: An experimental investigation [J].
Abed, Azhar Ahmed ;
Ahmed, Omer Khalil ;
Weis, Musa Mustafa ;
Hamada, Khalaf Ibrahim .
RENEWABLE ENERGY, 2020, 157 :515-529
[2]   Enhancement of the performance of Photovoltaic/Trombe wall system using the porous medium: Experimental and theoretical study [J].
Ahmed, Omer K. ;
Hamad, Khalaf I. ;
Salih, Abdulrazzaq M. .
ENERGY, 2019, 171 :14-26
[3]   Experimental evaluation of the optimal position of a macroencapsulated phase change material incorporated composite roof under hot climate conditions [J].
Al-Yasiri, Qudama ;
Szab, Marta .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 45
[4]  
[Anonymous], Energy Plus Weather Data by Region: Portugal
[5]  
[Anonymous], The Solar LongWave Environmental Irradiance Geometry model (SOLWEIG)
[6]  
[Anonymous], CARBON EMISSIONS CAL
[7]  
[Anonymous], 2020, China building energy consumption research report
[8]   Optimal positioning of phase change material and insulation through numerical investigations to reduce cooling loads in office buildings [J].
Arumugam, Pappu ;
Ramalingam, Velraj ;
Vellaichamy, Pandiyarajan .
JOURNAL OF ENERGY STORAGE, 2022, 52
[9]   Optimisation analysis of PCM-enhanced opaque building envelope components for the energy retrofitting of office buildings in Mediterranean climates [J].
Cascone, Ylenia ;
Capozzoli, Alfonso ;
Perino, Marco .
APPLIED ENERGY, 2018, 211 :929-953
[10]   Solar absorption in a ventilated facade with PCM. Experimental results [J].
de Gracia, Alvaro ;
Navarro, Lidia ;
Castell, Albert ;
Ruiz-Pardo, Alvaro ;
Alvarez, Servando ;
Cabeza, Luisa F. .
1ST INTERNATIONAL CONFERENCE ON SOLAR HEATING AND COOLING FOR BUILDINGS AND INDUSTRY (SHC 2012), 2012, 30 :986-994