Automated blood pressure measuring devices: how are they clinically validated for accuracy?

被引:5
|
作者
Ringrose, Jennifer S. [1 ,2 ]
Padwal, Raj [1 ,2 ]
机构
[1] Univ Alberta, Dept Med, Edmonton, AB, Canada
[2] Women & Childrens Hlth Res Inst, Edmonton, AB, Canada
关键词
HYPERTENSION-INTERNATIONAL-PROTOCOL; MEDICAL INSTRUMENTATION/EUROPEAN SOCIETY; EUROPEAN-SOCIETY; HYPERTENSION/INTERNATIONAL ORGANIZATION; UNIVERSAL STANDARD; ASSOCIATION; ADVANCEMENT; PREVENTION; MONITORS; ADULTS;
D O I
10.1038/s41371-022-00761-2
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Accurate blood pressure (BP) assessment is essential for the optimal diagnosis and management of hypertension. Contemporary clinical practice guidelines strongly endorse use of automated cuff blood pressure measuring devices (BPMD) as the preferred means of measuring and monitoring BP in the office, at home and with ambulatory blood pressure monitoring. To ensure that they are accurate, automated BPMDs should undergo clinical validation testing, performed using an established clinical validation standard. Unfortunately, most BPMDs sold on the global market have not been clinically validated. Furthermore, in the last thirty years, several different clinical validation protocols have been published, with major differences apparent between these standards, causing controversy with respect to which standard is considered acceptable for clinical validation. Complexly worded standards, multiple revisions, and firewalled access also contribute to a lack of understanding and use of clinical validation standards and the number of expert centers performing clinical validations is small. Recently, joint society collaborations have led to creation of the AAMI/ESH/ISO universal standard for the clinical validation of automated cuff BPMDs. Not only is this unified standard a necessary step, but oversight from regulators and influential stakeholders to ensure that only clinically validated BPMDs can be marketed is additionally needed.
引用
收藏
页码:101 / 107
页数:7
相关论文
共 50 条
  • [1] Automated blood pressure measuring devices: how are they clinically validated for accuracy?
    Jennifer S. Ringrose
    Raj Padwal
    Journal of Human Hypertension, 2023, 37 : 101 - 107
  • [2] How to find and use validated blood pressure measuring devices
    Dean S. Picone
    Raj Padwal
    George S. Stergiou
    Jordana B. Cohen
    Richard J. McManus
    Siegfried Eckert
    Kei Asayama
    Neil Atkins
    Michael Rakotz
    Cintia Lombardi
    Tammy M. Brady
    James E. Sharman
    Journal of Human Hypertension, 2023, 37 : 108 - 114
  • [3] How to find and use validated blood pressure measuring devices
    Picone, Dean S.
    Padwal, Raj
    Stergiou, George S.
    Cohen, Jordana B.
    McManus, Richard J.
    Eckert, Siegfried
    Asayama, Kei
    Atkins, Neil
    Rakotz, Michael
    Lombardi, Cintia
    Brady, Tammy M.
    Sharman, James E.
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (02) : 108 - 114
  • [4] The quest for accuracy of blood pressure measuring devices
    O'Brien, Eoin
    Stergiou, George S.
    Turner, Martin J.
    JOURNAL OF CLINICAL HYPERTENSION, 2018, 20 (07): : 1092 - 1095
  • [5] Automated 'oscillometric' blood pressure measuring devices: how they work and what they measure
    Sharman, James E.
    Tan, Isabella
    Stergiou, George S.
    Lombardi, Carolina
    Saladini, Francesca
    Butlin, Mark
    Padwal, Raj
    Asayama, Kei
    Avolio, Alberto
    Brady, Tammy M.
    Murray, Alan
    Parati, Gianfranco
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (02) : 93 - 100
  • [6] Automated ‘oscillometric’ blood pressure measuring devices: how they work and what they measure
    James E. Sharman
    Isabella Tan
    George S. Stergiou
    Carolina Lombardi
    Francesca Saladini
    Mark Butlin
    Raj Padwal
    Kei Asayama
    Alberto Avolio
    Tammy M. Brady
    Alan Murray
    Gianfranco Parati
    Journal of Human Hypertension, 2023, 37 : 93 - 100
  • [7] Journal of Human Hypertension special issue on the accuracy of automated blood pressure measuring devices
    James E. Sharman
    Journal of Human Hypertension, 2023, 37 : 91 - 92
  • [8] The influence of the method of data analysis on the reported accuracy of automated blood pressure measuring devices
    Braam, RL
    Thien, T
    JOURNAL OF HYPERTENSION, 2001, 19 (10) : 1765 - 1767
  • [9] Journal of Human Hypertension special issue on the accuracy of automated blood pressure measuring devices
    Sharman, James E.
    JOURNAL OF HUMAN HYPERTENSION, 2023, 37 (2) : 91 - 92
  • [10] AVAILABILITY OF PROPERLY VALIDATED AUTOMATED BLOOD PRESSURE MEASURING DEVICES FOR CHILDREN: STRIDE BP SYSTEMATIC REVIEW
    Menti, Ariadni
    Mariglis, Dimitrios
    Kyriakoulis, Konstantinos
    Kollias, Anastasios
    Palatini, Paolo
    Parati, Gianfranco
    Wang, Jiguang
    Schutte, Aletta
    Stergiou, George
    JOURNAL OF HYPERTENSION, 2024, 42 (SUPPL 3)