Inter-rater reliability and agreement of 6 Minute Walk Test and 10 Meter Walk Test at comfortable walk speed in patients with acute stroke

被引:11
|
作者
Busk, Henriette [1 ,2 ,3 ]
Holm, Paetur [1 ,4 ]
Skou, Soren [1 ,4 ]
Seitner, Simon [2 ]
Siemsen, Troels [2 ]
Wienecke, Troels [2 ,5 ]
机构
[1] Naestved Slagelse Ringsted Hosp, Dept Physiotherapy & Occupat Therapy, Res Unit PROgrez, DK-4200 Slagelse, Denmark
[2] Zealand Univ Hosp, Dept Neurol, Roskilde, Denmark
[3] Univ Copenhagen, Dept Neurosci, Copenhagen, Denmark
[4] Univ Southern Denmark, Dept Sports Sci & Clin Biomech, Res Unit Musculoskeletal Funct & Physiotherapy, Odense, Denmark
[5] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
Six Minute Walk Test; Ten Meter Walk Test; reliability; agreement; acute stroke; TEST-RETEST RELIABILITY; 6-MINUTE WALK; PROPORTIONAL RECOVERY; REHABILITATION; POSTSTROKE; VALIDITY; EXERCISE; TIME; RECOMMENDATIONS; INDIVIDUALS;
D O I
10.1080/09593985.2022.2030830
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: Remediation of gait problems is a key feature of neurological physiotherapy We aimed to investigate the inter-rater reliability and agreement of the Six Minute Walk Test (6MWT) and Ten Meter Walk Test (10MWT), at comfortable walking speed, in hospitalized acute ischemic stroke patients. Method: Forty acute first-time patients with brain stem or hemispheric ischemic stroke aged 67.4 +/- 12.5 (SD), able to walk with or without an assistive device, were tested by one of three physiotherapists. Test-retest reliability was evaluated using a one-way random effects single measures model (1,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Agreement was evaluated using the Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC). Results: Both tests demonstrated good reliability; ICC1,1 0.83 (CI 95% 0.70-0.90) (6MWT) and 0.76 (CI 95% 0.59-0.87) (10MWT). The 6MWT-SEM was 27.2 m (m) and the SDC was 75.4 m. The 10MWT-SEM was 0.36 meters per second (m/s) and the SDC was 1.0 m/s. Conclusion: Both tests demonstrated good inter-rater reliability, confirming their discriminative ability on a group of hospitalized first-time acute ischemic stroke patients. However, the measurement error was large for both tests, which is likely due to spontaneous neurological recovery and stress in the acute phase severely affecting the individual-level agreement estimate.
引用
收藏
页码:1024 / 1032
页数:9
相关论文
共 50 条
  • [31] 4-meter walk test in patients with Parkinson's disease: A reliability and validity study
    Ozkan, Taskin
    Soke, Fatih
    Ataoglu, Nigar Esra Erkoc
    Karakoc, Selda
    Gulsen, Cagri
    Kocer, Bilge
    Comoglu, Selim Selcuk
    Kaplan, Funda
    Bora, Hatice Ayse Tokcaer
    GAIT & POSTURE, 2025, 119 : 87 - 92
  • [32] Reliability of the two-minute walk test in individuals with transtibial amputation
    Brooks, D
    Hunter, JP
    Parsons, J
    Livsey, E
    Quirt, J
    Devlin, M
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 2002, 83 (11): : 1562 - 1565
  • [33] Estimating endurance shuttle walk test speed using the six-minute walk test in people with chronic obstructive pulmonary disease
    Wootton, Sally L.
    Ng, Cindy
    McKeough, Zoe J.
    Jenkins, Sue
    Hill, Kylie
    Alison, Jennifer A.
    CHRONIC RESPIRATORY DISEASE, 2014, 11 (02) : 89 - 94
  • [34] Concurrent validity of walking speed measured by a wearable sensor and a stopwatch during the 10-meter walk test in individuals with stroke
    Cleland, Brice T.
    Alex, Titus
    Madhavan, Sangeetha
    GAIT & POSTURE, 2023, 107 : 61 - 66
  • [35] Validity of the Six-Minute Walk Test in Cancer Patients
    Schmidt, K.
    Vogt, L.
    Thiel, C.
    Jaeger, E.
    Banzer, W.
    INTERNATIONAL JOURNAL OF SPORTS MEDICINE, 2013, 34 (07) : 631 - 636
  • [36] Reliability of the Fox-walk test in patients with rheumatoid arthritis
    Verberkt, Cornelia Antonia
    Friden, Cecilia
    Grooten, Wilhelmus Johannes Andreas
    Opava, Christina H.
    DISABILITY AND REHABILITATION, 2012, 34 (23) : 2001 - 2006
  • [37] Gait Monitoring and Walk Distance Estimation With an Accelerometer During 6-Minute Walk Test
    Retory, Yann
    David, Pascal
    Niedzialkowski, Pauline
    de Picciotto, Carole
    Bonay, Marcel
    Petitjean, Michel
    RESPIRATORY CARE, 2019, 64 (08) : 923 - 930
  • [38] Reference value of 6-minute walk distance in patients with sub-acute stroke
    Kubo, Hiroki
    Nozoe, Masafumi
    Kanai, Masashi
    Furuichi, Asami
    Onishi, Akira
    Kajimoto, Kazuki
    Mase, Kyoshi
    Shimada, Shinichi
    TOPICS IN STROKE REHABILITATION, 2020, 27 (05) : 337 - 343
  • [39] Repeatability of the 6-Minute Walk Test in Adolescents and Adults With Cystic Fibrosis
    Ziegler, Bruna
    Eidt Rovedder, Paula Maria
    Oliveira, Claudine Lacerda
    de Abreu e Silva, Fernando
    Roth Dalcin, Paulo de Tarso
    RESPIRATORY CARE, 2010, 55 (08) : 1020 - 1025
  • [40] Reliability of the six-minute walk test in people with fibromyalgia
    Pankoff, BA
    Overend, TJ
    Lucy, SD
    White, KP
    ARTHRITIS CARE AND RESEARCH, 2000, 13 (05): : 291 - 295