Inter-rater reliability and agreement of 6 Minute Walk Test and 10 Meter Walk Test at comfortable walk speed in patients with acute stroke

被引:11
|
作者
Busk, Henriette [1 ,2 ,3 ]
Holm, Paetur [1 ,4 ]
Skou, Soren [1 ,4 ]
Seitner, Simon [2 ]
Siemsen, Troels [2 ]
Wienecke, Troels [2 ,5 ]
机构
[1] Naestved Slagelse Ringsted Hosp, Dept Physiotherapy & Occupat Therapy, Res Unit PROgrez, DK-4200 Slagelse, Denmark
[2] Zealand Univ Hosp, Dept Neurol, Roskilde, Denmark
[3] Univ Copenhagen, Dept Neurosci, Copenhagen, Denmark
[4] Univ Southern Denmark, Dept Sports Sci & Clin Biomech, Res Unit Musculoskeletal Funct & Physiotherapy, Odense, Denmark
[5] Univ Copenhagen, Dept Clin Med, Copenhagen, Denmark
关键词
Six Minute Walk Test; Ten Meter Walk Test; reliability; agreement; acute stroke; TEST-RETEST RELIABILITY; 6-MINUTE WALK; PROPORTIONAL RECOVERY; REHABILITATION; POSTSTROKE; VALIDITY; EXERCISE; TIME; RECOMMENDATIONS; INDIVIDUALS;
D O I
10.1080/09593985.2022.2030830
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: Remediation of gait problems is a key feature of neurological physiotherapy We aimed to investigate the inter-rater reliability and agreement of the Six Minute Walk Test (6MWT) and Ten Meter Walk Test (10MWT), at comfortable walking speed, in hospitalized acute ischemic stroke patients. Method: Forty acute first-time patients with brain stem or hemispheric ischemic stroke aged 67.4 +/- 12.5 (SD), able to walk with or without an assistive device, were tested by one of three physiotherapists. Test-retest reliability was evaluated using a one-way random effects single measures model (1,1) absolute agreement-type Interclass Correlation Coefficient (ICC). Agreement was evaluated using the Standard Error of Measurement (SEM) and Smallest Detectable Change (SDC). Results: Both tests demonstrated good reliability; ICC1,1 0.83 (CI 95% 0.70-0.90) (6MWT) and 0.76 (CI 95% 0.59-0.87) (10MWT). The 6MWT-SEM was 27.2 m (m) and the SDC was 75.4 m. The 10MWT-SEM was 0.36 meters per second (m/s) and the SDC was 1.0 m/s. Conclusion: Both tests demonstrated good inter-rater reliability, confirming their discriminative ability on a group of hospitalized first-time acute ischemic stroke patients. However, the measurement error was large for both tests, which is likely due to spontaneous neurological recovery and stress in the acute phase severely affecting the individual-level agreement estimate.
引用
收藏
页码:1024 / 1032
页数:9
相关论文
共 50 条
  • [21] Concurrent Validity and Test-Retest Reliability of the 3-Meter Backward Walk Test in Stroke Survivors
    Kapan, Ali
    Ristic, Milos
    Yang, Lin
    Kranz, Gottfried
    Waldhoer, Thomas
    HEALTHCARE, 2023, 11 (23)
  • [22] Interrater Reliability of the 6-Minute Walk Test in Women With Hip Fracture
    Overgaard, Jan Arnholtz
    Larsen, Camilla Marie
    Holtze, Steffen
    Ockholm, Kenneth
    Kristensen, Morten Tange
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2017, 40 (03) : 158 - 166
  • [23] Test-retest reliability, agreement, and minimal detectable change in the 6-minute walk test in patients with intermittent claudication
    Sandberg, Anna
    Cider, Asa
    Jivegard, Lennart
    Nordanstig, Joakim
    Wittboldt, Susanna
    Back, Maria
    JOURNAL OF VASCULAR SURGERY, 2020, 71 (01) : 197 - 203
  • [24] Reproducibility and relationships of the 6-minute walk test and shuttle walk test in children with cerebral palsy
    Silva, Natalia
    Cahalin, Lawrence
    Dal Corso, Simone
    Ross, Arena
    Oliveira, Claudia
    Sampaio, Luciana Malosa
    EUROPEAN RESPIRATORY JOURNAL, 2016, 48
  • [25] Reliability and validity of the 4-meter walk test in patients with multiple sclerosis
    Ozkan, Taskin
    Unluer, Nezehat Ozgul
    Ates-Sari, Yasemin
    Hangun, Suleyman Furkan
    Vural, Gonul
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2024, 87
  • [26] The Six-Minute Walk Test for adults with intellectual disability: A study of validity and reliability
    Nasuti, Gabriella
    Stuart-Hill, Lynneth
    Temple, Viviene A.
    JOURNAL OF INTELLECTUAL & DEVELOPMENTAL DISABILITY, 2013, 38 (01) : 31 - 38
  • [27] Reliability and Validity of the 10-Meter Walk Test (10MWT) in Adolescents and Young Adults with Down Syndrome
    Sanchez-Gonzalez, Juan Luis
    Llamas-Ramos, Ines
    Llamas-Ramos, Rocio
    Molina-Rueda, Francisco
    Carratala-Tejada, Maria
    Cuesta-Gomez, Alicia
    CHILDREN-BASEL, 2023, 10 (04):
  • [28] Inter-rater and Intra-rater Reliability of the Chinese Version of the Action Research Arm Test in People With Stroke
    Zhao, Jiang-Li
    Chen, Pei-Ming
    Zhang, Tao
    Li, Hai
    Lin, Qiang
    Mao, Yu-Rong
    Huang, Dong-Feng
    FRONTIERS IN NEUROLOGY, 2019, 10
  • [29] Reliability of the six-minute walk test in individuals with stroke: systematic review and meta-analysis
    Macchiavelli, Alice
    Giffone, Antonella
    Ferrarello, Francesco
    Paci, Matteo
    NEUROLOGICAL SCIENCES, 2021, 42 (01) : 81 - 87
  • [30] Safety of the Cardiopulmonary 6-Minute Walk Test
    Guimaraes, Guilherme Veiga
    Carvalho, Vitor Oliveira
    Belli, Juliana Fernanda
    ARQUIVOS BRASILEIROS DE CARDIOLOGIA, 2010, 95 (05) : 671 - 671