Assessment of fetal corpus callosum biometry by 3D super-resolution reconstructed T2-weighted magnetic resonance imaging

被引:1
作者
Lamon, Samuel [1 ,2 ,3 ,4 ]
de Dumast, Priscille [1 ,2 ,3 ]
Sanchez, Thomas [1 ,2 ,3 ]
Dunet, Vincent [1 ,2 ]
Pomar, Leo [2 ,4 ,5 ]
Vial, Yvan [2 ,4 ]
Koob, Meriam [1 ,2 ]
Cuadra, Meritxell Bach [1 ,2 ,3 ]
机构
[1] Lausanne Univ Hosp, Dept Radiol, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] CIBM Ctr Biomed Imaging, Lausanne, Switzerland
[4] Lausanne Univ Hosp, Dept Woman Mother Child, Ultrasound & Fetal Med, Lausanne, Switzerland
[5] Univ Appl Sci & Arts Western Switzerland, Sch Hlth Sci HESAV, Lausanne, Switzerland
来源
FRONTIERS IN NEUROLOGY | 2024年 / 15卷
基金
瑞士国家科学基金会;
关键词
super-resolution reconstruction; magnetic resonance imaging; ultrasound; biometry; fetal brain; corpus callosum; corpus callosum segments; agenesis of the corpus callosum; UPDATED SONOGRAPHIC EXAMINATION; VOLUME RECONSTRUCTION; BRAIN MRI; PERFORMANCE;
D O I
10.3389/fneur.2024.1358741
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To assess the accuracy of corpus callosum (CC) biometry, including sub-segments, using 3D super-resolution fetal brain MRI (SR) compared to 2D or 3D ultrasound (US) and clinical low-resolution T2-weighted MRI (T2WS).Method Fetal brain biometry was conducted by two observers on 57 subjects [21-35 weeks of gestational age (GA)], including 11 cases of partial CC agenesis. Measures were performed by a junior observer (obs1) on US, T2WS and SR and by a senior neuroradiologist (obs2) on T2WS and SR. CC biometric regression with GA was established. Statistical analysis assessed agreement within and between modalities and observers.Results This study shows robust SR to US concordance across gestation, surpassing T2WS. In obs1, SR aligns with US, except for genu and CC length (CCL), enhancing splenium visibility. In obs2, SR closely corresponds to US, differing in rostrum and CCL. The anterior CC (rostrum and genu) exhibits higher variability. SR's regression aligns better with literature (US) for CCL, splenium and body than T2WS. SR is the method with the least missing values.Conclusion SR yields CC biometry akin to US (excluding anterior CC). Thanks to superior 3D visualization and better through plane spatial resolution, SR allows to perform CC biometry more frequently than T2WS.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] CT-Guided, Unsupervised Super-Resolution Reconstruction of Single 3D Magnetic Resonance Image
    Wang, Jiale
    Heimann, Alexander F.
    Tannast, Moritz
    Zheng, Guoyan
    MEDICAL IMAGE COMPUTING AND COMPUTER ASSISTED INTERVENTION, MICCAI 2023, PT I, 2023, 14220 : 497 - 507
  • [22] Value of T2-weighted magnetic resonance imaging in the assessment of wall inflammation and fibrosis in Crohn's disease
    Maccioni, F.
    Staltari, I.
    Pino, A. R.
    Tiberti, A.
    ABDOMINAL IMAGING, 2012, 37 (06): : 944 - 957
  • [23] Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla
    Vos, E. K.
    Lagemaat, M. W.
    Barentsz, J. O.
    Fuetterer, J. J.
    Zamecnik, P.
    Roozen, H.
    Orzada, S.
    Bitz, A. K.
    Maas, M. C.
    Scheenen, T. W. J.
    EUROPEAN RADIOLOGY, 2014, 24 (08) : 1950 - 1958
  • [24] 3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements
    Pier, Danielle B.
    Gholipour, Ali
    Afacan, Onur
    Velasco-Annis, Clemente
    Clancy, Sean
    Kapur, Kush
    Estroff, Judy A.
    Warfield, Simon K.
    JOURNAL OF NEUROIMAGING, 2016, 26 (05) : 539 - 544
  • [25] 3D In Vitro Ultrasound Super-Resolution Imaging using a Clinical System
    Christensen-Jeffries, Kirsten
    Harput, Sevan
    Brown, Jemma
    Zhang, Ge
    Zhu, Jiaqi
    Tang, Meng-Xing
    Dunsby, Christopher
    Eckersley, Robert
    2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
  • [26] Deep learning-based super-resolution of 3D magnetic resonance images by regularly spaced shifting
    Thurnhofer-Hemsi, Karl
    Lopez-Rubio, Ezequiel
    Dominguez, Enrique
    Marcos Luque-Baena, Rafael
    Roe-Vellve, Nuria
    NEUROCOMPUTING, 2020, 398 : 314 - 327
  • [27] Data Quality Assessment for Super-Resolution Fetal Brain MR Imaging: A Retrospective 1.5 T Study
    Rubert, Nicholas
    Bardo, Dianna M. E.
    Vaughn, Jennifer
    Cornejo, Patricia
    Goncalves, Luis F.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (04) : 1349 - 1360
  • [28] Automatic segmentation of human supraclavicular adipose tissue using high-resolution T2-weighted magnetic resonance imaging
    Wu, Bingxia
    Cheng, Chuanli
    Qi, Yulong
    Zhou, Hongyu
    Peng, Hao
    Wan, Qian
    Liu, Xin
    Zheng, Hairong
    Zhang, Huimao
    Zou, Chao
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (04) : 641 - 649
  • [29] High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis
    El Sanharawi, Imane
    Tzarouchi, Loukia
    Cardoen, Liesbeth
    Martinerie, Laetitia
    Leger, Juliane
    Carel, Jean-Claude
    Elmaleh-Berges, Monique
    Alison, Marianne
    PEDIATRIC RADIOLOGY, 2017, 47 (05) : 599 - 605
  • [30] Automatic segmentation of human supraclavicular adipose tissue using high-resolution T2-weighted magnetic resonance imaging
    Bingxia Wu
    Chuanli Cheng
    Yulong Qi
    Hongyu Zhou
    Hao Peng
    Qian Wan
    Xin Liu
    Hairong Zheng
    Huimao Zhang
    Chao Zou
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 641 - 649