Assessment of fetal corpus callosum biometry by 3D super-resolution reconstructed T2-weighted magnetic resonance imaging

被引:1
作者
Lamon, Samuel [1 ,2 ,3 ,4 ]
de Dumast, Priscille [1 ,2 ,3 ]
Sanchez, Thomas [1 ,2 ,3 ]
Dunet, Vincent [1 ,2 ]
Pomar, Leo [2 ,4 ,5 ]
Vial, Yvan [2 ,4 ]
Koob, Meriam [1 ,2 ]
Cuadra, Meritxell Bach [1 ,2 ,3 ]
机构
[1] Lausanne Univ Hosp, Dept Radiol, Lausanne, Switzerland
[2] Univ Lausanne, Lausanne, Switzerland
[3] CIBM Ctr Biomed Imaging, Lausanne, Switzerland
[4] Lausanne Univ Hosp, Dept Woman Mother Child, Ultrasound & Fetal Med, Lausanne, Switzerland
[5] Univ Appl Sci & Arts Western Switzerland, Sch Hlth Sci HESAV, Lausanne, Switzerland
来源
FRONTIERS IN NEUROLOGY | 2024年 / 15卷
基金
瑞士国家科学基金会;
关键词
super-resolution reconstruction; magnetic resonance imaging; ultrasound; biometry; fetal brain; corpus callosum; corpus callosum segments; agenesis of the corpus callosum; UPDATED SONOGRAPHIC EXAMINATION; VOLUME RECONSTRUCTION; BRAIN MRI; PERFORMANCE;
D O I
10.3389/fneur.2024.1358741
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective To assess the accuracy of corpus callosum (CC) biometry, including sub-segments, using 3D super-resolution fetal brain MRI (SR) compared to 2D or 3D ultrasound (US) and clinical low-resolution T2-weighted MRI (T2WS).Method Fetal brain biometry was conducted by two observers on 57 subjects [21-35 weeks of gestational age (GA)], including 11 cases of partial CC agenesis. Measures were performed by a junior observer (obs1) on US, T2WS and SR and by a senior neuroradiologist (obs2) on T2WS and SR. CC biometric regression with GA was established. Statistical analysis assessed agreement within and between modalities and observers.Results This study shows robust SR to US concordance across gestation, surpassing T2WS. In obs1, SR aligns with US, except for genu and CC length (CCL), enhancing splenium visibility. In obs2, SR closely corresponds to US, differing in rostrum and CCL. The anterior CC (rostrum and genu) exhibits higher variability. SR's regression aligns better with literature (US) for CCL, splenium and body than T2WS. SR is the method with the least missing values.Conclusion SR yields CC biometry akin to US (excluding anterior CC). Thanks to superior 3D visualization and better through plane spatial resolution, SR allows to perform CC biometry more frequently than T2WS.
引用
收藏
页数:11
相关论文
共 50 条
[21]   Value of T2-weighted magnetic resonance imaging in the assessment of wall inflammation and fibrosis in Crohn’s disease [J].
F. Maccioni ;
I. Staltari ;
A. R. Pino ;
A. Tiberti .
Abdominal Imaging, 2012, 37 :944-957
[22]   Value of T2-weighted magnetic resonance imaging in the assessment of wall inflammation and fibrosis in Crohn's disease [J].
Maccioni, F. ;
Staltari, I. ;
Pino, A. R. ;
Tiberti, A. .
ABDOMINAL IMAGING, 2012, 37 (06) :944-957
[23]   A comparison study between 3D T2-weighted SPACE and conventional 2D T2-weighted turbo spin echo in assessment of carotid plaque [J].
Peng Lv ;
Yuanyuan Dai ;
Jiang Lin ;
Weisheng Zhang ;
Hao Liu ;
Hui Liu ;
Xiao Tang .
The International Journal of Cardiovascular Imaging, 2017, 33 :395-400
[24]   Accelerated High-resolution T1-and T2-weighted Breast MRI with Deep Learning Super-resolution Reconstruction [J].
Mesropyan, Narine ;
Katemann, Christoph ;
Leutner, Claudia ;
Sommer, Alexandra ;
Isaak, Alexander ;
Weber, Oliver M. ;
Peeters, Johannes M. ;
Dell, Tatjana ;
Bischoff, Leon ;
Kuetting, Daniel ;
Pieper, Claus C. ;
Lakghomi, Asadeh ;
Luetkens, Julian A. .
ACADEMIC RADIOLOGY, 2025, 32 (06) :3147-3156
[25]   Image quality and cancer visibility of T2-weighted Magnetic Resonance Imaging of the prostate at 7 Tesla [J].
Vos, E. K. ;
Lagemaat, M. W. ;
Barentsz, J. O. ;
Fuetterer, J. J. ;
Zamecnik, P. ;
Roozen, H. ;
Orzada, S. ;
Bitz, A. K. ;
Maas, M. C. ;
Scheenen, T. W. J. .
EUROPEAN RADIOLOGY, 2014, 24 (08) :1950-1958
[26]   3D Super-Resolution Motion-Corrected MRI: Validation of Fetal Posterior Fossa Measurements [J].
Pier, Danielle B. ;
Gholipour, Ali ;
Afacan, Onur ;
Velasco-Annis, Clemente ;
Clancy, Sean ;
Kapur, Kush ;
Estroff, Judy A. ;
Warfield, Simon K. .
JOURNAL OF NEUROIMAGING, 2016, 26 (05) :539-544
[27]   3D In Vitro Ultrasound Super-Resolution Imaging using a Clinical System [J].
Christensen-Jeffries, Kirsten ;
Harput, Sevan ;
Brown, Jemma ;
Zhang, Ge ;
Zhu, Jiaqi ;
Tang, Meng-Xing ;
Dunsby, Christopher ;
Eckersley, Robert .
2018 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2018,
[28]   Deep learning-based super-resolution of 3D magnetic resonance images by regularly spaced shifting [J].
Thurnhofer-Hemsi, Karl ;
Lopez-Rubio, Ezequiel ;
Dominguez, Enrique ;
Marcos Luque-Baena, Rafael ;
Roe-Vellve, Nuria .
NEUROCOMPUTING, 2020, 398 :314-327
[29]   High-resolution heavily T2-weighted magnetic resonance imaging for evaluation of the pituitary stalk in children with ectopic neurohypophysis [J].
Imane El Sanharawi ;
Loukia Tzarouchi ;
Liesbeth Cardoen ;
Laetitia Martinerie ;
Juliane Leger ;
Jean-Claude Carel ;
Monique Elmaleh-Berges ;
Marianne Alison .
Pediatric Radiology, 2017, 47 :599-605
[30]   Data Quality Assessment for Super-Resolution Fetal Brain MR Imaging: A Retrospective 1.5 T Study [J].
Rubert, Nicholas ;
Bardo, Dianna M. E. ;
Vaughn, Jennifer ;
Cornejo, Patricia ;
Goncalves, Luis F. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (04) :1349-1360