Flexor Tendon Repair with Fast-Absorbable Sutures: A Rupture Incidence-Focused Analysis of a Case Series and a Review

被引:0
作者
Macionis, Valdas [1 ]
机构
[1] Fabijoniskiu 11, LT-07122 Vilnius, Lithuania
来源
MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL | 2024年 / 14卷 / 01期
关键词
Absorbable suture; flexor tendon; hand; repair; review; ENGINEERED TENDON; PASSIVE MOBILIZATION; ACTIVE MOBILIZATION; GLIDING RESISTANCE; IN-VIVO; STRENGTH; SURGERY; TENORRHAPHY; ABSORPTION; SIZE;
D O I
10.32098/mltj.01.2024.19
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hand flexor tendon repair with absorbable sutures has the advantage of leaving no foreign material within the tendon. However, clinical application of degradable materials in flexor tendon repair is limited to slow -absorbable PDS or Maxon sutures and commonly does not involve fast -absorbable sutures, probably, because of fear of ruptures. Meanwhile, a small number of reports have shown that in terms of tenorrhaphy failure fast -absorbable sutures are safe. It is also known that classical tendon repairs with a pull-out wire withstand intensive mobilization after wire removal. Furthermore, experimental research implies that fast -absorbable polyglycolic acid fibers seeded with tenocytes can strengthen tendon repair. The current article retrospectively analyses a series of 12 patients with predominantly complex hand injuries, in which 17 flexor digitorum profundus and four flexor pollicis longus tendon repairs with Vicryl (polyglactin 910, copolymer of polyglycolic and polylactic acid) were performed. Early postoperative passive mobilization was employed. The postoperative results were analyzed with particular reference to tenorrhaphy failure. Ruptures occurred in only two repairs. This was statistically insignificant when compared with a hypothetical set of cases consisting of only good and excellent outcomes. These results imply that hand flexor tendon repair with fast -absorbable sutures is rupture -safe if moderate postoperative mobilization is employed. However, as the calculated postoperative dynamics of the tenorrhaphy strength predicts failure of all fast -absorbable suture repairs during active motion at six weeks, more research is needed to clarify why this was not the case in the presented and other published series of patients.
引用
收藏
页码:219 / 227
页数:9
相关论文
共 82 条
[1]  
Acan A.E., 2018, KNOTS ORTHOPEDIC SUR, P21, DOI DOI 10.1007/978-3-662-56108-9_3
[2]   Gliding Resistance and Modifications of Gliding Surface of Tendon Clinical Perspectives [J].
Amadio, Peter C. .
HAND CLINICS, 2013, 29 (02) :159-+
[3]   Biomechanical and histologic characteristics of canine flexor tendon repair using early postoperative mobilization [J].
Aoki, M ;
Kubota, H ;
Pruitt, DL ;
Manske, PR .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (01) :107-114
[4]   Inflammatory reaction to suture materials after flexor tendon repair. A retrospective study of 594 patients [J].
Arner, Marianne ;
Unge, Linda ;
Franko, Mikael A. ;
Svingen, Jonas .
CASE REPORTS IN PLASTIC SURGERY AND HAND SURGERY, 2023, 10 (01)
[5]   Sterilization, toxicity, biocompatibility and clinical applications of polylactic acid polyglycolic acid copolymers [J].
Athanasiou, KA ;
Niederauer, GG ;
Agrawal, CM .
BIOMATERIALS, 1996, 17 (02) :93-102
[6]   Investigating the knot performance of silk, polyamide, polyester, and polypropylene sutures [J].
Bayraktar, EK ;
Hockenberger, AS .
TEXTILE RESEARCH JOURNAL, 2001, 71 (05) :435-440
[7]  
BEAUCHAMP PJ, 1988, J REPROD MED, V33, P615
[8]   Primary flexor tendons repair in zone 2: Current trends with GEMMSOR survey results [J].
Bigorre, N. ;
Delaquaize, F. ;
Degez, F. ;
Celerier, S. .
HAND SURGERY & REHABILITATION, 2018, 37 (05) :281-288
[9]   PROBLEMS OF TENDON SURGERY [J].
BOYES, JH .
AMERICAN JOURNAL OF SURGERY, 1965, 109 (03) :269-&
[10]  
BRUCK J C, 1985, Handchirurgie Mikrochirurgie Plastische Chirurgie, V17, P238