Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study

被引:5
|
作者
Yan, Shuang G. [1 ]
Cui, Yiliang [1 ]
Li, Di [2 ,6 ]
Liu, Fanxiao [3 ]
Hua, Xingyi [1 ]
Schmidutz, Florian [4 ,5 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, Hefei, Peoples R China
[2] Naval Med Univ, Changhai Hosp, Affiliated Hosp 1, Dept Orthopaed Surg, Shanghai, Peoples R China
[3] Shandong First Med Univ, Shandong Prov Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Univ Hosp Munich LMU, Dept Orthopaed Surg Phys Med & Rehabil, Munich, Germany
[5] Ortho Zentrum Rosenheim, Rosenheim, Germany
[6] Naval Med Univ, Changhai Hosp, Dept Orthopaed Surg, Shanghai, Peoples R China
关键词
Cannulated cancellous screws; femoral neck fracture; femoral neck system; internal fixation; ADULTS; HIP;
D O I
10.1080/08941939.2023.2266752
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the clinical results of a new femoral neck system (FNS) and cannulated compression screws (CCS) for the treatment of femoral neck fractures in younger patients.Methods: Retrospective study was performed in younger patients with femoral neck fractures that were treated with FNS or CCS from August 2017 to August 2022. The hip functional outcomes were assessed with the Harris hip score (HHS). Secondary outcomes included the surgical time, surgical blood loss, satisfaction visual analog scale (VAS), fluoroscopy frequency, fracture healing time and complications.Results: A total of 49 patients (22 FNS and 27 CCS) with a minimum follow-up of 12 months were included. There was also no significant difference in HHSs (p = 0.27) and satisfaction VAS (p = 0.10) between them. Patients with FNS had more blood loss (50.45 +/- 5.28 mL vs. 20.67 +/- 4.71 ml, p < 0.01), lower fluoroscopy frequency (16.64 +/- 3.32 vs. 23.59 +/- 3.39, p < 0.01) and lower fracture healing time (3.76 +/- 0.42 vs. 4.46 +/- 0.59 months, p < 0.01). The femoral neck shortening and incidence of nail withdrawal in the FNS group was significantly lower than CCS group (2.91 +/- 1.95 vs. 4.44 +/- 1.52 mm, p < 0.01; 4.5% vs. 22.2%, p = 0.03).Conclusions: The FNS and CCS get similar hip functions. The FNS can reduce fluoroscopy exposure and the complications such as femoral neck shortening and nail withdrawal. Thus, FNS can be an alternative to CCS for the fixation of femoral neck fractures in younger patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Nonanatomical reduction of femoral neck fractures in young patients treated with femoral neck system: a retrospective cohort study
    Jiang, Qilong
    Liu, Yang
    Bai, Xinwen
    Deng, Yu
    Cao, Yong
    Yu, Chengxiang
    Song, Qizhi
    Li, Yan
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [42] Nonanatomical reduction of femoral neck fractures in young patients treated with femoral neck system: a retrospective cohort study
    Qilong Jiang
    Yang Liu
    Xinwen Bai
    Yu Deng
    Yong Cao
    Chengxiang Yu
    Qizhi Song
    Yan Li
    BMC Musculoskeletal Disorders, 24
  • [43] Proximal Femoral Locking Plate With Cannulated Screws for the Treatment of Femoral Neck Fractures
    Lin, Dasheng
    Lian, Kejian
    Ding, Zhenqi
    Zhai, Wenliang
    Hong, Jiayuan
    ORTHOPEDICS, 2012, 35 (01) : E1 - E5
  • [44] Multiple cannulated screw fixation of young femoral neck fractures
    Kim, Joo Yong
    Kong, Gyu Min
    Park, Dae Hyun
    Kim, Dae Yoo
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2015, 31 (06) : 1517 - 1520
  • [45] Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study
    Yunfeng Tang
    Zhen Zhang
    Limin Wang
    Wei Xiong
    Qian Fang
    Guanglin Wang
    Journal of Orthopaedic Surgery and Research, 16
  • [46] The comparison of femoral neck system and cancellous screws internal fixation for femoral neck fracture
    Jiang, Tao
    Gao, Han
    Xu, Bin
    Lv, Fuxin
    Liu, Tao
    BIOTECHNOLOGY AND GENETIC ENGINEERING REVIEWS, 2024, 40 (03) : 1947 - 1958
  • [47] Bio-mechanical effects of femoral neck system versus cannulated screws on treating young patients with Pauwels type III femoral neck fractures: a finite element analysis
    Fan, Xiao
    Zhou, Yimin
    Dai, Shiyou
    Lao, Kecheng
    Zhang, Qiliang
    Yu, Tengbo
    BMC MUSCULOSKELETAL DISORDERS, 2024, 25 (01)
  • [48] A new angle and its relationship with early fixation failure of femoral neck fractures treated with three cannulated compression screws
    Zhang, Y. L.
    Zhang, W.
    Zhang, C. Q.
    ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2017, 103 (02) : 229 - 234
  • [49] Biomechanical Evaluation of the Femoral Neck System in Unstable Pauwels III Femoral Neck Fractures: A Comparison with the Dynamic Hip Screw and Cannulated Screws
    Stoffel, Karl
    Zderic, Ivan
    Gras, Florian
    Sommer, Christoph
    Eberli, Ursula
    Mueller, David
    Oswald, Martin
    Gueorguiev, Boyko
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2017, 31 (03) : 131 - 137
  • [50] Biomechanical Research of Three Parallel Cannulated Compression Screws in Oblique Triangle Configuration for Fixation of Femoral Neck Unstable Fractures
    Zhang, Ru-Yi
    Zhang, Wu-Peng
    Yang, Guang-Min
    Wang, Dao-Feng
    Su, Peng
    Zhang, Yi
    Nie, Shao-Bo
    Li, Jia
    Zhao, Zhe
    Li, Jian-Tao
    Zhang, Li-Cheng
    Tang, Pei-Fu
    ORTHOPAEDIC SURGERY, 2024, 16 (04) : 953 - 964