Femoral Neck System versus Three Cannulated Screws for Fixation of Femoral Neck Fractures in Younger Patients: A Retrospective Cohort Study

被引:5
|
作者
Yan, Shuang G. [1 ]
Cui, Yiliang [1 ]
Li, Di [2 ,6 ]
Liu, Fanxiao [3 ]
Hua, Xingyi [1 ]
Schmidutz, Florian [4 ,5 ]
机构
[1] Anhui Med Univ, Affiliated Hosp 1, Dept Orthopaed Surg, Hefei, Peoples R China
[2] Naval Med Univ, Changhai Hosp, Affiliated Hosp 1, Dept Orthopaed Surg, Shanghai, Peoples R China
[3] Shandong First Med Univ, Shandong Prov Hosp, Dept Orthopaed, Jinan, Peoples R China
[4] Univ Hosp Munich LMU, Dept Orthopaed Surg Phys Med & Rehabil, Munich, Germany
[5] Ortho Zentrum Rosenheim, Rosenheim, Germany
[6] Naval Med Univ, Changhai Hosp, Dept Orthopaed Surg, Shanghai, Peoples R China
关键词
Cannulated cancellous screws; femoral neck fracture; femoral neck system; internal fixation; ADULTS; HIP;
D O I
10.1080/08941939.2023.2266752
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: To compare the clinical results of a new femoral neck system (FNS) and cannulated compression screws (CCS) for the treatment of femoral neck fractures in younger patients.Methods: Retrospective study was performed in younger patients with femoral neck fractures that were treated with FNS or CCS from August 2017 to August 2022. The hip functional outcomes were assessed with the Harris hip score (HHS). Secondary outcomes included the surgical time, surgical blood loss, satisfaction visual analog scale (VAS), fluoroscopy frequency, fracture healing time and complications.Results: A total of 49 patients (22 FNS and 27 CCS) with a minimum follow-up of 12 months were included. There was also no significant difference in HHSs (p = 0.27) and satisfaction VAS (p = 0.10) between them. Patients with FNS had more blood loss (50.45 +/- 5.28 mL vs. 20.67 +/- 4.71 ml, p < 0.01), lower fluoroscopy frequency (16.64 +/- 3.32 vs. 23.59 +/- 3.39, p < 0.01) and lower fracture healing time (3.76 +/- 0.42 vs. 4.46 +/- 0.59 months, p < 0.01). The femoral neck shortening and incidence of nail withdrawal in the FNS group was significantly lower than CCS group (2.91 +/- 1.95 vs. 4.44 +/- 1.52 mm, p < 0.01; 4.5% vs. 22.2%, p = 0.03).Conclusions: The FNS and CCS get similar hip functions. The FNS can reduce fluoroscopy exposure and the complications such as femoral neck shortening and nail withdrawal. Thus, FNS can be an alternative to CCS for the fixation of femoral neck fractures in younger patients.
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Femoral neck system versus inverted cannulated cancellous screw for the treatment of femoral neck fractures in adults: a preliminary comparative study
    Tang, Yunfeng
    Zhang, Zhen
    Wang, Limin
    Xiong, Wei
    Fang, Qian
    Wang, Guanglin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2021, 16 (01)
  • [32] What is the Fate of Undisplaced Femoral Neck Fractures Treated With Cannulated Screws?
    Slullitel, Pablo A.
    Latallade, Valentino
    Huespe, Ivan A.
    Lucero-Viviani, Nicolas
    Buttaro, Martin A.
    JOURNAL OF ARTHROPLASTY, 2024, 39 (01) : 111 - 117
  • [33] Cannulated Screws or Hemiarthroplasty for Femoral Neck Fractures: Is There a Mortality Difference?
    Thompson, Austen L.
    Kuttner, Nicolas P.
    Greenberg, Marc
    Hidden, Krystin A.
    Yuan, Brandon J.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2024, 38 (11) : 596 - 601
  • [34] A comparative study of internal fixation with porous tantalum screws and cannulated screws in the treatment of femoral neck fractures
    Dewei Zhao
    Yu Zhang
    Liangliang Cheng
    Zhijie Ma
    Feng Wang
    Xing Qiu
    Jiawei Ying
    Tianwei Zhang
    Fuyang Wang
    Scientific Reports, 15 (1)
  • [35] Comparison of femoral neck system and three cannulated cancellous screws in the treatment of vertical femoral neck fractures: clinical observation and finite element analysis
    Shaolong Huang
    Yazhong Zhang
    Xu Zhang
    Chengqiang Zhou
    Wenbo Li
    Yunqing Wang
    Bin Wang
    Ziqiang Zhu
    BioMedical Engineering OnLine, 22
  • [36] Internal fixation using fully threaded cannulated compression screws for fresh femoral neck fractures in adults
    Yuan, Kai-xuan
    Yang, Fan
    Fu, Kai
    Zhu, Dao-yu
    Jiang, Chen-yi
    Jin, Dong-xu
    Wang, Ze-hao
    Peng, Xiao-yuan
    Gao, You-Shui
    Luo, Peng-bo
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2022, 17 (01)
  • [37] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Zheng Wang
    Yong Yang
    Gangning Feng
    Haohui Guo
    Zhirong Chen
    Yaogeng Chen
    Qunhua Jin
    BioMedical Engineering OnLine, 21
  • [38] Is there an increased risk for subtrochanteric stress fracture with the Femoral Neck System versus multiple cannulated screws fixation?
    Hsu, Megan R.
    Shu, Henry T.
    Luksameearunothai, Kitchai
    Margalit, Adam
    Yu, Andrew T.
    Hasenboehler, Erik A.
    Shafiq, Babar
    JOURNAL OF ORTHOPAEDICS, 2022, 30 : 127 - 133
  • [39] Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures
    Xu, Xiangyu
    Fan, Jixing
    Zhou, Fang
    Lv, Yang
    Tian, Yun
    Ji, Hongquan
    Zhang, Zhishan
    Guo, Yan
    Yang, Zhongwei
    Hou, Guojin
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54 : S28 - S35
  • [40] Biomechanical comparison of the femoral neck system versus InterTan nail and three cannulated screws for unstable Pauwels type III femoral neck fracture
    Wang, Zheng
    Yang, Yong
    Feng, Gangning
    Guo, Haohui
    Chen, Zhirong
    Chen, Yaogeng
    Jin, Qunhua