Quantitative and qualitative image quality assessment in shoulder examinations with a first-generation photon-counting detector CT

被引:9
作者
Patzer, Theresa Sophie [1 ]
Kunz, Andreas Steven [1 ]
Huflage, Henner [1 ]
Luetkens, Karsten Sebastian [1 ]
Conrads, Nora [1 ]
Gruschwitz, Philipp [1 ]
Pannenbecker, Pauline [1 ]
Erguen, Sueleyman [2 ]
Bley, Thorsten Alexander [1 ]
Grunz, Jan-Peter [1 ]
机构
[1] Univ Hosp Wurzburg, Dept Diagnost & Intervent Radiol, Oberdurrbacher Str 6, D-97080 Wurzburg, Germany
[2] Univ Wurzburg, Inst Anat & Cell Biol, Koellikerstr 6, D-97070 Wurzburg, Germany
关键词
COMPUTED-TOMOGRAPHY; FORMALIN;
D O I
10.1038/s41598-023-35367-2
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Photon-counting detector (PCD) CT allows for ultra-high-resolution (UHR) examinations of the shoulder without requiring an additional post-patient comb filter to narrow the detector aperture. This study was designed to compare the PCD performance with a high-end energy-integrating detector (EID) CT. Sixteen cadaveric shoulders were examined with both scanners using dose-matched 120 kVp acquisition protocols (low-dose/full-dose: CTDIvol=5.0/10.0 mGy). Specimens were scanned in UHR mode with the PCD-CT, whereas EID-CT examinations were conducted in accordance with the clinical standard as "non-UHR". Reconstruction of EID data employed the sharpest kernel available for standard-resolution scans (rho(50)=12.3 lp/cm), while PCD data were reconstructed with both a comparable kernel (11.8 lp/cm) and a sharper dedicated bone kernel (16.5 lp/cm). Six radiologists with 2-9 years of experience in musculoskeletal imaging rated image quality subjectively. Interrater agreement was analyzed by calculation of the intraclass correlation coefficient in a two-way random effects model. Quantitative analyses comprised noise recording and calculating signal-to-noise ratios based on attenuation measurements in bone and soft tissue. Subjective image quality was higher in UHR-PCD-CT than in EID-CT and non-UHR-PCD-CT datasets (all p<0.001). While low-dose UHR-PCD-CT was considered superior to full-dose non-UHR studies on either scanner (all p<0.001), ratings of low-dose non-UHR-PCD-CT and full-dose EID-CT examinations did not differ (p>0.99). Interrater reliability was moderate, indicated by a single measures intraclass correlation coefficient of 0.66 (95% confidence interval: 0.58-0.73; p<0.001). Image noise was lowest and signal-to-noise ratios were highest in non-UHR-PCD-CT reconstructions at either dose level (p<0.001). This investigation demonstrates that superior depiction of trabecular microstructure and considerable denoising can be realized without additional radiation dose by employing a PCD for shoulder CT imaging. Allowing for UHR scans without dose penalty, PCD-CT appears as a promising alternative to EID-CT for shoulder trauma assessment in clinical routine.
引用
收藏
页数:8
相关论文
共 29 条
  • [1] Ultra-high-resolution imaging of the shoulder and pelvis using photon-counting-detector CT: a feasibility study in patients
    Baffour, Francis, I
    Rajendran, Kishore
    Glazebrook, Katrina N.
    Thorne, Jamison E.
    Larson, Nicholas B.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    [J]. EUROPEAN RADIOLOGY, 2022, 32 (10) : 7079 - 7086
  • [2] Influence of formalin fixation on the biomechanical properties of human diaphyseal bone
    Burkhart, Klaus J.
    Nowak, Tobias E.
    Blum, Jochen
    Kuhn, Sebastian
    Welker, Marcel
    Sternstein, Werner
    Mueller, Lars P.
    Rommens, Pol M.
    [J]. BIOMEDIZINISCHE TECHNIK, 2010, 55 (06): : 361 - 365
  • [3] Management of Scapular Fractures
    Cole, Peter A.
    Gauger, Erich M.
    Schroder, Lisa K.
    [J]. JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2012, 20 (03) : 130 - 141
  • [4] Injury Mechanism of Acute Anterior Shoulder Dislocation Associated with Glenoid and Greater Tuberosity Fractures: A Study Based on Fracture Morphology
    Dai, Fei
    Xiang, Ming
    Yang, Jin-song
    Chen, Hang
    Hu, Xiao-chuan
    Zhang, Qing
    Li, Yi-ping
    [J]. ORTHOPAEDIC SURGERY, 2020, 12 (05) : 1421 - 1429
  • [5] Photon-counting CT review
    Flohr, Thomas
    Petersilka, Martin
    Henning, Andre
    Ulzheimer, Stefan
    Ferda, Jiri
    Schmidt, Bernhard
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 79 : 126 - 136
  • [6] Effect of 10% formalin on radiographic optical density of bone specimens
    Fonseca, A. A.
    Cherubini, K.
    Veeck, E. B.
    Ladeira, R. S.
    Carapeto, L. P.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2008, 37 (03) : 137 - 141
  • [7] How to deal with a glenoid fracture
    Frich, Lars Henrik
    Larsen, Morten Schultz
    [J]. EFORT OPEN REVIEWS, 2017, 2 (05): : 151 - 157
  • [8] Spectral Shaping Via Tin Prefiltration in Ultra-High-Resolution Photon-Counting and Energy-Integrating Detector CT of the Temporal Bone
    Grunz, Jan-Peter
    Heidenreich, Julius Frederik
    Lennartz, Simon
    Weighardt, Jens Philipp
    Bley, Thorsten Alexander
    Erguen, Sueleyman
    Petritsch, Bernhard
    Huflage, Henner
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (12) : 819 - 825
  • [9] Ultra-Low-Dose Photon-Counting CT Imaging of the Paranasal Sinus With Tin Prefiltration How Low Can We Go?
    Grunz, Jan-Peter
    Petritsch, Bernhard
    Luetkens, Karsten Sebastian
    Kunz, Andreas Steven
    Lennartz, Simon
    Ergun, Suleyman
    Bley, Thorsten Alexander
    Huflage, Henner
    [J]. INVESTIGATIVE RADIOLOGY, 2022, 57 (11) : 728 - 733
  • [10] Image Quality Assessment for Clinical Cadmium Telluride-Based Photon-Counting Computed Tomography Detector in Cadaveric Wrist Imaging
    Grunz, Jan-Peter
    Huflage, Henner
    Heidenreich, Julius Frederik
    Erguen, Suleyman
    Petersilka, Martin
    Allmendinger, Thomas
    Bley, Thorsten Alexander
    Petritsch, Bernhard
    [J]. INVESTIGATIVE RADIOLOGY, 2021, 56 (12) : 785 - 790