Case Studies for Supplying the Alternating Current Auxiliary Systems of Substations with a Voltage Equal to or Higher than 230 kV

被引:2
作者
Cavalcanti, Mariana de Morais [1 ]
Costa, Tatiane [2 ]
Pereira, Alex C. [3 ]
Jatoba, Eduardo B. [3 ]
Filho, Jose Bione de Melo [3 ]
Barreto, Elisabete [3 ]
Mohamed, Mohamed A. [4 ]
Ilinca, Adrian [5 ]
Marinho, Manoel H. N. [1 ]
机构
[1] Univ Pernambuco UPE, PostGrad Program Syst Engn PPGES, BR-50100010 Recife, PE, Brazil
[2] Edson Mororo Moura Inst Technol ITEMM, 733 Padre Carapuceiro St, BR-51020280 Recife, PE, Brazil
[3] Sao Francisco Hydroelect Co Chesf, BR-50761901 Recife, PE, Brazil
[4] Minia Univ, Fac Engn, Dept Elect Engn, Al Minya 61519, Egypt
[5] Ecole Technol Super, Dept Mech Engn, 1100 Rue Notre Dame Ouest, Montreal, PQ H3C 1K3, Canada
关键词
BESS; diesel generation; auxiliary services; substation; photovoltaic; HOMER;
D O I
10.3390/en16145396
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
This paper presents case studies for replacing diesel generators (DGs) that are used as the main and emergency power sources for alternating current (AC) auxiliary services in substations (SS) within the transmission network (voltage greater than or equal to 230 kV). The objective of this research is to present a solution that is more reliable, environmentally friendly, and financially viable than DGs. To achieve this, the proposed solutions incorporate Battery Energy Storage Systems (BESSs) with or without the integration of Photovoltaic (PV) Systems. These solutions were simulated using the HOMER PRO Version 3.14.5 software for the Messias SS /AL, and the results were analyzed and compared to the DG in terms of reliability, financial viability, and environmental impact. Based on the conducted analyses, the BESS solution with the PV system was found to be the most suitable for the main source. However, in the case of the emergency source, if one of the main sources is a DG/BESS, maintaining the emergency DG is the preferable option. If both main sources are independent, the BESS solution with the PV system is a suitable solution.
引用
收藏
页数:25
相关论文
共 43 条
  • [31] Uses, Cost-Benefit Analysis, and Markets of Energy Storage Systems for Electric Grid Applications
    Liu, Jinqiang
    Hu, Chao
    Kimber, Anne
    Wang, Zhaoyu
    [J]. JOURNAL OF ENERGY STORAGE, 2020, 32
  • [32] Materioteca UFSC, US
  • [33] Meireles T., WWF
  • [34] Merlin V.L., US
  • [35] Miller NW, 1996, ELEVENTH ANNUAL BATTERY CONFERENCE ON APPLICATIONS AND ADVANCES, P235, DOI 10.1109/BCAA.1996.485001
  • [36] moura, MOURA BATTERIE
  • [37] Case Study of Backup Application with Energy Storage in Microgrids
    Nascimento, Rafaela
    Ramos, Felipe
    Pinheiro, Aline
    de Araujo Silva Jr, Washington
    Arcanjo, Ayrlw M. C.
    Dias Filho, Roberto F.
    Mohamed, Mohamed A. A.
    Marinho, Manoel H. N.
    [J]. ENERGIES, 2022, 15 (24)
  • [38] Operational Data Analysis of a Battery Energy Storage System to Support Wind Energy Generation
    Pontes, Luana
    Costa, Tatiane
    Souza, Amanda
    Dantas, Nicolau
    Vasconcelos, Andrea
    Rissi, Guilherme
    Dias, Roberto
    Mohamed, Mohamed A.
    Siano, Pierluigi
    Marinho, Manoel
    [J]. ENERGIES, 2023, 16 (03)
  • [39] Development of Operation Strategy for Battery Energy Storage System into Hybrid AC Microgrids
    Ramos, Felipe
    Pinheiro, Aline
    Nascimento, Rafaela
    Silva Junior, Washington de Araujo
    Mohamed, Mohamed A.
    Annuk, Andres
    Marinho, Manoel H. N.
    [J]. SUSTAINABILITY, 2022, 14 (21)
  • [40] Recarbrio, about us