Regenerator performance using freezing concentration for heat source tower heat pump system

被引:5
|
作者
Han, Chong [1 ,2 ]
Yu, Muyang [1 ,2 ]
Hou, Chongchong [1 ,2 ]
Jiang, Huimin [3 ]
Chen, Chuanbao [3 ]
Yao, Yang [1 ,2 ]
Ni, Long [1 ,2 ]
机构
[1] Harbin Inst Technol, Sch Architecture, Harbin 150090, Peoples R China
[2] Minist Ind & Informat Technol, Key Lab Cold Reg Urban & Rural Human Settlement En, Harbin, Peoples R China
[3] Nanjing Wuzhou Refrigerat Grp Co Ltd, Nanjing, Peoples R China
基金
中国国家自然科学基金;
关键词
Heat source tower heat pump; Freeze concentration; Refrigeration; Heat transfer; Freezing process; DESICCANT;
D O I
10.1016/j.applthermaleng.2023.121053
中图分类号
O414.1 [热力学];
学科分类号
摘要
Freeze concentration has a good regeneration effect and is easy for latent heat utilization. The electronic expansion valve opening has a great impact on the icing process. Hence, to investigate variations in the freezing process and gain the optimum regeneration effect, a solution regenerator was tested under different system-side control strategies. The solution volume flow was 5 m3/h and the electronic expansion valve opening degree (OEEV) was from 100% to 50%. For ice-covering growth, ice in low opening degree spent a long time to cover the plate. The area of ice under 100% to 65% OEEV was 1.43 times that under 50% OEEV. Peak velocities from 100% to 50% OEEV all appeared in the early stage of icing development. Moreover, the low opening degree made the ice distribute unevenness. The percentage slope of 100% OEEV was 1.23% and that of 50% OEEV was 3.46%. In addition, decreasing ice thickness uniformity was beneficial to the separation process. The separation ratio from 100% to 50% OEEV was 49.51%, 51.67%, 57.88%, and 74.54%, respectively. Both the low average thickness growth rate and high separation ratio were beneficial to increase the regeneration concentration. The effective specific ice production rate was from 100% to 50% OEEV was 5.99 kg/kWh, 6.18 kg/kWh, 6.94 kg/kWh, and 6.88 kg/kWh, respectively. Results showed that 65% OEEV operation was optimum for the solution regenerator unit using freeze concentration.
引用
收藏
页数:15
相关论文
共 50 条
  • [31] Multifactor analysis on beach well infiltration intake system for seawater source heat pump
    Jia, Xin
    Lin Duanmu
    Shu, Haiwen
    ENERGY AND BUILDINGS, 2017, 154 : 244 - 253
  • [32] Large-area seepage and heat transfer model of beach well infiltration intake system for seawater source heat pump
    Xin, Jia
    Lin, Duanmu
    Shu Haiwen
    ENERGY AND BUILDINGS, 2018, 158 : 1593 - 1601
  • [33] 4E analyses of novel dual-heat source/sink ejector-compression heat pump system
    Liu, Jian
    Tian, Xue
    Lin, Zhang
    BUILDING AND ENVIRONMENT, 2021, 196
  • [34] Heating Performance of Solar Heat Pump Heating System With Aluminum Tube Collector
    Wu Zhenkui
    Yang Peihong
    Jiang Hui
    Wei Yili
    Zhang Jihong
    Zhang Zilei
    Zhang Xiaoming
    IEEE ACCESS, 2021, 9 (09): : 26491 - 26501
  • [35] Review of energy efficiency and system performance of residential heat pump water heaters
    Willem, H.
    Lin, Y.
    Lekov, A.
    ENERGY AND BUILDINGS, 2017, 143 : 191 - 201
  • [36] Effect of heat transfer on the performance of a thermoelectric heat pump driven by a thermoelectric generator
    Chen, Lingen
    Meng, Fankai
    Sun, Fengrui
    REVISTA MEXICANA DE FISICA, 2009, 55 (04) : 282 - 291
  • [37] Experimental test on heating performance of backwash falling film sewage source heat pump unit
    Zhang Q.
    Yang Y.
    Zhang X.
    Liu F.
    Huagong Jinzhan/Chemical Industry and Engineering Progress, 2022, 41 (05): : 2698 - 2705
  • [38] Performance investigation of air-source heat pump heating system with novel thermal storage refrigerant-heated panel
    Shao S.
    Zhang H.
    You S.
    Zheng W.
    Huagong Xuebao/CIESC Journal, 2020, 71 (08): : 3480 - 3489
  • [39] Experimental Study on a Heat-Source Tower under Different Configurations
    Cheng, Jianlin
    Li, Nianping
    Cui, Haijiao
    Li, Tengbo
    JOURNAL OF ENERGY ENGINEERING, 2020, 146 (03)
  • [40] PERFORMANCE OF REFRIGERATION & HEAT PUMP SYSTEM BY USING BINARY MIXTURES OF R32/R744
    Sun, Zhili
    Li, Minxia
    Ma, Yitai
    Wang, Pai
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 551 - 561