Analysis of biometric parameters of cataract eyes measured with optical biometer Lenstar LS900, IOL Master 700, and OPD-SCAN III

被引:6
作者
Bao, Tong [1 ]
Wang, Lifeng [1 ]
Liu, Caihui [1 ]
Yang, Yajun [2 ]
Pang, Yunlei [3 ]
机构
[1] Chifeng Chaoju Eye Hosp, Dept Ophthalmol Examinat, Chifeng, Peoples R China
[2] Chifeng Chaoju Eye Hosp, Dept Cataract, Chifeng, Peoples R China
[3] Chifeng Chaoju Eye Hosp, Dept Ophthalm Plast Surg, Chifeng, Peoples R China
关键词
Biometry; Cataract; Swept source optical coherence tomography; Cornea indicators; CHAMBER DEPTH MEASUREMENTS; DEVICE;
D O I
10.1016/j.pdpdt.2023.103646
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To compare the characteristics of biometric measurements among the LS900, IOL Master, and OPD-SCAN III in patients with mild-to-moderate cataract. Methods: We recruited 85 eyes of 78 patients diagnosed with mild-to-moderate cataract at our hospital between January and April 2023. The K (average corneal curvature; K1 and K2), astigmatism (AST), and white to white (WTW) were measured using those three devices, respectively. Differences and correlations between those measures based on the device were explored. Results: The K1, K2, and AST were highly consistent among the groups (P = 0.851, P = 0.626, P = 0.473, respectively). The WTW measured by IOL Master were larger than those measured by the LS900 and OPD-SCAN III (all P < 0.001). However, all three devices were highly correlated in all measures (P < 0.001). Bland-Altman plots indicated a significant agreement between three devices in all measurements (P < 0.001). Conclusions: K1, K2, and AST in patients with mild-to-moderate cataract were similar among all three devices, whereas the WTW were not. WTW measurement differences between three devices should be concerned in cataract cases.
引用
收藏
页数:4
相关论文
共 15 条
[11]   Comparison of Axial Length, Corneal Curvature, and Anterior Chamber Depth Measurements of 2 Recently Introduced Devices to a Known Biometer [J].
Shajari, Mehdi ;
Cremonese, Carla ;
Petermann, Kerstin ;
Singh, Pankaj ;
Mueller, Michael ;
Kohnen, Thomas .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2017, 178 :58-64
[12]   Comparison of Corneal Diameter and Anterior Chamber Depth Measurements Using 4 Different Devices [J].
Shajari, Mehdi ;
Lehmann, Ulrike C. ;
Kohnen, Thomas .
CORNEA, 2016, 35 (06) :838-842
[13]  
Song Jae Shin, 2020, Korean J Ophthalmol, V34, P126, DOI 10.3341/kjo.2019.0102
[14]   Characteristics and factors associated with the position of the haptic after ICL V4C implantation [J].
Tan, Weina ;
Chen, Qian ;
Yang, Ruibo ;
Wang, Zheng ;
Zeng, Qingyan ;
Lei, Xiaohua ;
Jin, Lina ;
Zhao, Shaozhen .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2023, 49 (04) :416-422
[15]   Effect of pupil dilation on biometry measurements and intraocular lens power in eyes with high myopia [J].
Xi, Wenqun ;
Yang, Mingmin ;
Wan, Jinci ;
Wang, Yuan ;
Qiao, Yuanjiao ;
Huang, Xiaosheng ;
Liu, Xinhua ;
Fan, Ning ;
Liu, Shenwen ;
Zeng, Kun ;
Chen, Sheng .
FRONTIERS IN MEDICINE, 2022, 9