Development of ASTM International D8405-Standard Test Method for Evaluating PM2.5 Sensors or Sensor Systems Used in Indoor Applications

被引:1
|
作者
Mui, Wilton [1 ,3 ]
Kuang, Xiaobi Michelle [1 ]
Zhang, Hang [1 ]
Bhandari, Sahil [2 ]
Dominguez, Raul [1 ]
Polidori, Andrea [1 ]
Papapostolou, Vasileios [1 ]
机构
[1] South Coast Air Qual Management Dist, Diamond Bar, CA USA
[2] Univ British Columbia, Vancouver, BC, Canada
[3] South Coast Air Qual Management Dist, 21865 Copley Dr, Diamond Bar, CA 91765 USA
关键词
Air monitoring; indoor air; low-cost sensor; particulate; performance evaluation; test standard; AIR-QUALITY SENSORS; PARTICULATE MATTER; PARTICLE SENSORS; COST; PERFORMANCE; EXPOSURE;
D O I
10.1080/15459624.2023.2212739
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Sensors and sensor systems for monitoring fine particles with aerodynamic diameters smaller than 2.5 mu m can provide real-time feedback on indoor air quality and thus can help guide actions to manage indoor air pollutant concentrations. Standardized verification of the performance and accuracy of sensors and sensor systems is crucial for predicting the efficacy of such monitoring. A new ASTM International standard test method (ASTM D8405) was created for this need and is the most exacting laboratory protocol published to date for evaluating indoor air quality sensors and sensor systems measuring particles smaller than 2.5 mu m in diameter. ASTM D8405 subjects sensors and sensor systems to five test phases: (1) an initial particle concentration ramp; (2) exposure to various temperature and humidity conditions; (3) exposure to interfering particles; (4) temperature cycling; and (5) a final particle concentration ramp to assess drift. This paper discusses the development of the standard test method, key aspects of the testing process, example evaluation results, and a comparison of this standard test method against peer evaluation protocols.
引用
收藏
页码:373 / 389
页数:17
相关论文
共 2 条
  • [1] Development of a static test apparatus for evaluating the performance of three PM2.5 separators commonly used in China
    Peng Du
    Jianguo Liu
    Huaqiao Gui
    Jiaoshi Zhang
    Tongzhu Yu
    Jie Wang
    Yin Cheng
    Yihuai Lu
    Yawei Yao
    Qiang Fu
    ChihChieh Chen
    Journal of Environmental Sciences, 2020, 87 (01) : 238 - 249
  • [2] Development of a static test apparatus for evaluating the performance of three PM2.5 separators commonly used in China
    Du, Peng
    Liu, Jianguo
    Gui, Huaqiao
    Zhang, Jiaoshi
    Yu, Tongzhu
    Wang, Jie
    Cheng, Yin
    Lu, Yihuai
    Yao, Yawei
    Fu, Qiang
    Chen, ChihChieh
    JOURNAL OF ENVIRONMENTAL SCIENCES, 2020, 87 (87): : 238 - 249