Influence of office furniture on exposure risk to respiratory infection under mixing and displacement air distribution systems

被引:11
|
作者
Hatif, Ihab Hasan [1 ]
Kamar, Haslinda Mohamed [1 ,3 ]
Kamsah, Nazri [1 ]
Wong, Keng Yinn [1 ]
Tan, Huiyi [2 ]
机构
[1] Univ Teknol Malaysia, Fac Mech Engn, Johor Baharu, Malaysia
[2] Univ Teknol Malaysia, Fac Chem & Energy Engn, Johor Baharu, Malaysia
[3] Univ Teknol Malaysia, Fac Mech Engn, UTM, Skudai 81310, Johor, Malaysia
关键词
Exposure risk; Convective boundary layer; Office furniture; Physical barrier; Mixing ventilation; Displacement ventilation; AIRBORNE TRANSMISSION; DIFFERENT VENTILATION; INDOOR ENVIRONMENT; PERSONAL EXPOSURE; HUMAN-BODY; FLOW; CFD; OCCUPANTS; ROOM; DISPERSION;
D O I
10.1016/j.buildenv.2023.110292
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The furniture layout between two people complicates the interaction between indoor airflow, human thermal plume, and exhalation flow in the breathing microenvironment. It thus increases the uncertainty of exposure risk assessment. This study aims to investigate the effects of office furniture under two different air distribution systems on the transmission of respiratory contaminants and airborne cross-infection risk between two people using a computational fluid dynamics method. Two thermal manikins models with realistic breathing functions were simulated, sitting face to face at two separation distances between their mouths in a single-office room served by a mixing ventilation system (MV) and displacement ventilation system (DV). Tracer gas (N2O) was used to simulate small droplet nuclei pathogen-laden exhaled by the infected person, and the exposure risk was assessed using the intake fraction (IF) index. The results show that placing a desk in the microenvironment between two occupants increased the exposure risk by about 50% under DV conditions and 22% under MV conditions compared with the cases without a desk. The exposure risk was reduced remarkably by increasing the separating distance. The results show that the furniture layout significantly affects the airborne transmission risk and cross-infection, and this effect varies with the ventilation conditions and separation distances between the occupants.
引用
收藏
页数:14
相关论文
共 21 条
  • [1] Policy influence of formaldehyde exposure risk in air-conditioned office environment
    Mui, K. W.
    Wong, L. T.
    Hui, P. S.
    INDOOR AND BUILT ENVIRONMENT, 2008, 17 (05) : 449 - 454
  • [2] Influence of sensible cooling load on indoor air distribution in an office room with ceiling cooling and mixing ventilation
    Wu, Xiaozhou
    Wang, Haichao
    Gao, Jie
    Wang, Fenghao
    INDOOR AND BUILT ENVIRONMENT, 2021, 30 (07) : 957 - 969
  • [3] Investigation in performance of a hybrid under-floor air distribution with improved desk displacement ventilation system in a small office
    Rahmati, Bahram
    Heidarian, Ali
    Jadidi, Amir Mohammad
    APPLIED THERMAL ENGINEERING, 2018, 138 : 861 - 872
  • [4] Personal Exposure Risk Assessment of Respiratory Process under Effect of Limited Space Air Stability
    Deng X.
    Gong G.
    Wang R.
    He Y.
    Shi X.
    He X.
    Hunan Daxue Xuebao/Journal of Hunan University Natural Sciences, 2024, 51 (03): : 193 - 200
  • [5] Comparative evaluation of air distribution systems for controlling the airborne infection risk in indoor environments
    Hatif, Ihab Hasan
    Kamar, Haslinda Mohamed
    Kamsah, Nazri
    Wong, Keng Yinn
    JOURNAL OF BUILDING ENGINEERING, 2023, 79
  • [6] Experimental Research on the Temperature Distribution of Natural Displacement Ventilation in the Room under the Influence of Wind Pressure and Air Supply
    Liu, Zeqin
    Cai, Shuang
    Li, Size
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 989 - 995
  • [7] Contraction of Respiratory Viral Infection During air Travel: An Under-Recognized Health Risk for Athletes
    Ruuskanen, Olli
    Dollner, Henrik
    Luoto, Raakel
    Valtonen, Maarit
    Heinonen, Olli J.
    Waris, Matti
    SPORTS MEDICINE-OPEN, 2024, 10 (01)
  • [8] Comparison of Airflow and Contaminant Distributions in Rooms with Traditional Displacement Ventilation and Under-Floor Air Distribution Systems
    Lee, Kisup
    Zhang, Tengfei
    Jiang, Zheng
    Chen, Qingyan
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 2, 2009, 115 : 306 - +
  • [9] Study protocol: the effects of air pollution exposure and chronic respiratory disease on pneumonia risk in urban Malawian adults - the Acute Infection of the Respiratory Tract Study (The AIR Study)
    Hannah Jary
    Jane Mallewa
    Mulinda Nyirenda
    Brian Faragher
    Robert Heyderman
    Ingrid Peterson
    Stephen Gordon
    Kevin Mortimer
    BMC Pulmonary Medicine, 15
  • [10] Study protocol: the effects of air pollution exposure and chronic respiratory disease on pneumonia risk in urban Malawian adults - the Acute Infection of the Respiratory Tract Study (The AIR Study)
    Jary, Hannah
    Mallewa, Jane
    Nyirenda, Mulinda
    Faragher, Brian
    Heyderman, Robert
    Peterson, Ingrid
    Gordon, Stephen
    Mortimer, Kevin
    BMC PULMONARY MEDICINE, 2015, 15