Reconfigurable dipole receive array for dynamic parallel imaging at ultra-high magnetic field

被引:3
作者
Nikulin, Anton V. [1 ,2 ,3 ]
Glang, Felix [1 ]
Avdievich, Nikolai I. [1 ]
Bosch, Dario [1 ,2 ]
Steffen, Theodor [1 ]
Scheffler, Klaus [1 ,2 ]
机构
[1] Max Planck Inst Biol Cybernet, High Field MR Ctr, Tubingen, Germany
[2] Univ Tubingen, Dept Biomed Magnet Resonance, Tubingen, Germany
[3] Moscow Inst Phys & Technol, Ctr Photon & 2D Mat, Dolgoprudnyi, Russia
基金
欧洲研究理事会;
关键词
coil sensitivities; parallel imaging; reconfigurable RF coil; SENSE; ultra-high field MRI; COIL; SENSE; STRENGTH; BRAIN; LOOP; NMR;
D O I
10.1002/mrm.29745
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To extend the concept of 3D dynamic parallel imaging, we developed a prototype of an electronically reconfigurable dipole array that provides sensitivity alteration along the dipole length. Methods: We developed a radiofrequency array coil consisting of eight reconfigurable elevated-end dipole antennas. The receive sensitivity profile of each dipole can be electronically shifted toward one or the other end by electrical shortening or lengthening the dipole arms using positive-intrinsic-negative-diode lump-element switching units. Based on the results of electromagnetic simulations, we built the prototype and tested it at 9.4 T on phantom and healthy volunteer. A modified 3D SENSE reconstruction was used, and geometry factor (g-factor) calculations were performed to assess the new array coil. Results: Electromagnetic simulations showed that the new array coil was capable of alteration of its receive sensitivity profile along the dipole length. Electromagnetic and g-factor simulations showed closely agreeing predictions when compared to the measurements. The new dynamically reconfigurable dipole array provided significant improvement in geometry factor compared to static dipoles. We obtained up to 220% improvement for 3 x2 (Ry x Rz) acceleration compared to the static configuration case in terms of maximum g-factor and up to 54% in terms of mean g-factor for the same acceleration. Conclusion: We presented an 8-element prototype of a novel electronically reconfigurable dipole receive array that permits rapid sensitivity modulations along the dipole axes. Applying dynamic sensitivity modulation during image acquisition emulates two virtual rows of receive elements along the z-direction, and therefore improves parallel imaging performance for 3D acquisitions.
引用
收藏
页码:1713 / 1727
页数:15
相关论文
共 50 条
[41]   The Travelling-Wave Primate System: A New Solution for Magnetic Resonance Imaging of Macaque Monkeys at 7 Tesla Ultra-High Field [J].
Herrmann, Tim ;
Mallow, Johannes ;
Plaumann, Markus ;
Luchtmann, Michael ;
Stadler, Joerg ;
Mylius, Judith ;
Brosch, Michael ;
Bernarding, Johannes .
PLOS ONE, 2015, 10 (06)
[42]   Susceptibility-Weighted Imaging at Ultra-High Field (7 T) in the Evaluation of Brain Tumors [J].
Zee, Chi S. ;
Yan, Chenyu .
WORLD NEUROSURGERY, 2012, 77 (5-6) :654-656
[43]   Proton and multinuclear magnetic resonance spectroscopy in the human brain at ultra-high field strength: A review [J].
Henning, Anke .
NEUROIMAGE, 2018, 168 :181-198
[44]   Epilepsy under the scope of ultra-high field MRI [J].
Rondinoni, Carlo ;
Magnun, Celso ;
da Silva, Alexandre Vallota ;
Heinsen, Helmut Manfred ;
Amaro, Edson, Jr. .
EPILEPSY & BEHAVIOR, 2021, 121
[45]   Editorial: In Vivo Magnetic Resonance at Ultra High Field [J].
Zhu, He ;
Moser, Ewald .
FRONTIERS IN PHYSICS, 2017, 5
[46]   Homogeneous B1+ for bilateral breast imaging at 7 T using a five dipole transmit array merged with a high density receive loop array [J].
Krikken, Erwin ;
Steensma, Bart R. ;
Voogt, Ingmar J. ;
Luijten, Peter R. ;
Klomp, Dennis W. J. ;
Raaijmakers, Alexander J. E. ;
Wijnen, Jannie P. .
NMR IN BIOMEDICINE, 2019, 32 (02)
[47]   Encoding methods for B1+ mapping in parallel transmit systems at ultra high field [J].
Tse, Desmond H. Y. ;
Poole, Michael S. ;
Magill, Arthur W. ;
Felder, Joerg ;
Brenner, Daniel ;
Shah, N. Jon .
JOURNAL OF MAGNETIC RESONANCE, 2014, 245 :125-132
[48]   High Acceleration with a Rotating Radiofrequency Coil Array (RRFCA) in Parallel Magnetic Resonance Imaging (MRI) [J].
Li, Mingyan ;
Jin, Jin ;
Trakic, Adnan ;
Liu, Feng ;
Weber, Ewald ;
Li, Yu ;
Crozier, Stuart .
2012 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2012, :1098-1101
[49]   Safety of Ultra-High Field MRI: What are the Specific Risks? [J].
van Osch M.J.P. ;
Webb A.G. .
Current Radiology Reports, 2 (8)
[50]   Dynamic magnetic resonance imaging of swallowing and laryngeal motion using parallel imaging at 3 T [J].
Breyer, Tobias ;
Echternach, Matthias ;
Arndt, Susan ;
Richter, Bernhard ;
Speck, Oliver ;
Schumacher, Martin ;
Markl, Michael .
MAGNETIC RESONANCE IMAGING, 2009, 27 (01) :48-54