Reconfigurable dipole receive array for dynamic parallel imaging at ultra-high magnetic field

被引:3
作者
Nikulin, Anton V. [1 ,2 ,3 ]
Glang, Felix [1 ]
Avdievich, Nikolai I. [1 ]
Bosch, Dario [1 ,2 ]
Steffen, Theodor [1 ]
Scheffler, Klaus [1 ,2 ]
机构
[1] Max Planck Inst Biol Cybernet, High Field MR Ctr, Tubingen, Germany
[2] Univ Tubingen, Dept Biomed Magnet Resonance, Tubingen, Germany
[3] Moscow Inst Phys & Technol, Ctr Photon & 2D Mat, Dolgoprudnyi, Russia
基金
欧洲研究理事会;
关键词
coil sensitivities; parallel imaging; reconfigurable RF coil; SENSE; ultra-high field MRI; COIL; SENSE; STRENGTH; BRAIN; LOOP; NMR;
D O I
10.1002/mrm.29745
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To extend the concept of 3D dynamic parallel imaging, we developed a prototype of an electronically reconfigurable dipole array that provides sensitivity alteration along the dipole length. Methods: We developed a radiofrequency array coil consisting of eight reconfigurable elevated-end dipole antennas. The receive sensitivity profile of each dipole can be electronically shifted toward one or the other end by electrical shortening or lengthening the dipole arms using positive-intrinsic-negative-diode lump-element switching units. Based on the results of electromagnetic simulations, we built the prototype and tested it at 9.4 T on phantom and healthy volunteer. A modified 3D SENSE reconstruction was used, and geometry factor (g-factor) calculations were performed to assess the new array coil. Results: Electromagnetic simulations showed that the new array coil was capable of alteration of its receive sensitivity profile along the dipole length. Electromagnetic and g-factor simulations showed closely agreeing predictions when compared to the measurements. The new dynamically reconfigurable dipole array provided significant improvement in geometry factor compared to static dipoles. We obtained up to 220% improvement for 3 x2 (Ry x Rz) acceleration compared to the static configuration case in terms of maximum g-factor and up to 54% in terms of mean g-factor for the same acceleration. Conclusion: We presented an 8-element prototype of a novel electronically reconfigurable dipole receive array that permits rapid sensitivity modulations along the dipole axes. Applying dynamic sensitivity modulation during image acquisition emulates two virtual rows of receive elements along the z-direction, and therefore improves parallel imaging performance for 3D acquisitions.
引用
收藏
页码:1713 / 1727
页数:15
相关论文
共 50 条
[21]   Imaging cortical multiple sclerosis lesions with ultra-high field MRI [J].
Madsen, Mads A. J. ;
Wiggermann, Vanessa ;
Bramow, Stephan ;
Christensen, Jeppe Romme ;
Sellebjerg, Finn ;
Siebner, Hartwig R. .
NEUROIMAGE-CLINICAL, 2021, 32
[22]   Radio-frequency coils for ultra-high field magnetic resonance [J].
Ipek, Ozlem .
ANALYTICAL BIOCHEMISTRY, 2017, 529 :10-16
[23]   The Anti-Depressive Effects of Ultra-High Static Magnetic Field [J].
Lv, Yue ;
Fan, Yixiang ;
Tian, Xiaofei ;
Yu, Biao ;
Song, Chao ;
Feng, Chuanlin ;
Zhang, Lei ;
Ji, Xinmiao ;
Zablotskii, Vitalii ;
Zhang, Xin .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2022, 56 (02) :354-365
[24]   Awake Mouse fMRI and Pupillary Recordings in the Ultra-High Magnetic Field [J].
Zeng, Hang ;
Jiang, Yuanyuan ;
Beer-Hammer, Sandra ;
Yu, Xin .
FRONTIERS IN NEUROSCIENCE, 2022, 16
[25]   Neuroimaging with ultra-high field MRI: Present and future [J].
Polimeni, Jonathan R. ;
Uludag, Kamil .
NEUROIMAGE, 2018, 168 :1-6
[26]   Noise amplification in parallel whole-head ultra-low-field magnetic resonance imaging using 306 detectors [J].
Lin, Fa-Hsuan ;
Vesanen, Panu T. ;
Nieminen, Jaakko O. ;
Hsu, Yi-Cheng ;
Zevenhoven, Koos C. J. ;
Dabek, Juhani ;
Parkkonen, Lauri T. ;
Zhdanov, Andrey ;
Ilmoniemi, Risto J. .
MAGNETIC RESONANCE IN MEDICINE, 2013, 70 (02) :595-600
[27]   A Bore-Integrated Patch Antenna Array for Whole-Body Excitation in Ultra-High-Field Magnetic Resonance Imaging [J].
Egorova, Svetlana S. ;
Lisachenko, Nikolai A. ;
Kretov, Egor I. ;
Gao, Yang ;
Zhang, Xiaotong ;
Glybovski, Stanislav B. ;
Solomakha, Georgiy A. .
IEEE ACCESS, 2025, 13 :23120-23130
[28]   Slotted-waveguide array radio frequency coil for ultra-high-field magnetic resonance imaging [J].
Ilic, Milan M. ;
Notaros, Branislav M. .
CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2018, 48B (01)
[29]   Parallel imaging strategies for high-speed Magnetic Resonance diffusion imaging [J].
Bammer, R ;
Stollberger, R ;
Augustin, M ;
Seifert, T ;
Strasser-Fuchs, S ;
Wach, P ;
Hartung, HP ;
Fazekas, F .
MEDICAL IMAGING 2000: PHYSIOLOGY AND FUNCTION FORM MULTIDIMENSIONAL IMAGES, 2000, 3978 :12-22
[30]   Ultra-high field (7T) functional magnetic resonance imaging in amyotrophic lateral sclerosis: a pilot study [J].
Barry, Robert L. ;
Babu, Suma ;
Anteraper, Sheeba Arnold ;
Triantafyllou, Christina ;
Keil, Boris ;
Rowe, Olivia E. ;
Rangaprakash, D. ;
Paganoni, Sabrina ;
Lawson, Robert ;
Dheel, Christina ;
Cernasov, Paul M. ;
Rosen, Bruce R. ;
Ratai, Eva-Maria ;
Atassi, Nazem .
NEUROIMAGE-CLINICAL, 2021, 30