Investigation on the Effect of Debris Position on the Sensitivity of the Inductive Debris Sensor

被引:10
作者
Ma, Laihao [1 ]
Zhang, Hongpeng [1 ]
Zheng, Wenbo [1 ]
Shi, Haotian [1 ]
Wang, Chengjie [1 ]
Xie, Yucai [1 ]
机构
[1] Dalian Maritime Univ, Marine Engn Coll, Dalian 116026, Peoples R China
基金
中国国家自然科学基金;
关键词
Sensors; Magnetic fields; Oils; Sensitivity; Magnetic sensors; Inductance; Impedance; Wear debris; inductive debris sensor; radial position; sensitivity; WEAR DEBRIS; IDENTIFICATION;
D O I
10.1109/JSEN.2022.3155256
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The uneven radial magnetic field distribution in the planar coil will lead to debris detection errors, especially for inductive debris sensors with high throughput and sensitivity, so the effect of debris position on the detection sensitivity should be addressed. In this study, based on spatial magnetic field analysis of planar coil, the characteristics of impedance signals induced by debris at different positions in planar coil were investigated under different frequencies, debris sizes and velocities. The experimental results demonstrated that the double peaks generated in the induced signals can be eliminated without sacrificing the sensitivity by placing the sensor channel at the coil inner wall, and the sensitivity can be improved by observing resistance signals, increasing the frequencies and reducing debris velocities.
引用
收藏
页码:4438 / 4444
页数:7
相关论文
共 23 条
  • [1] MAGNETIC-FIELD EVALUATION FOR THICK ANNULAR CONDUCTORS
    AZZERBONI, B
    CARDELLI, E
    RAUGI, M
    TELLINI, A
    TINA, G
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 1993, 29 (03) : 2090 - 2094
  • [2] A high throughput inductive pulse sensor for online oil debris monitoring
    Du, Li
    Zhe, Jiang
    [J]. TRIBOLOGY INTERNATIONAL, 2011, 44 (02) : 175 - 179
  • [3] Real-time monitoring of wear debris in lubrication oil using a microfluidic inductive Coulter counting device
    Du, Li
    Zhe, Jiang
    Carletta, Joan
    Veillette, Robert
    Choy, Fred
    [J]. MICROFLUIDICS AND NANOFLUIDICS, 2010, 9 (06) : 1241 - 1245
  • [4] Feng L. Yang, IEEE SENSORS J
  • [5] Radial inductive debris detection sensor and performance analysis
    Hong, Wei
    Wang, Shaoping
    Tomovic, Mileta
    Han, Lei
    Shi, Jian
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2013, 24 (12)
  • [6] Comprehensive Improvement of the Sensitivity and Detectability of a Large-Aperture Electromagnetic Wear Particle Detector
    Jia, Ran
    Ma, Biao
    Zheng, Changsong
    Ba, Xin
    Wang, Liyong
    Du, Qiu
    Wang, Kai
    [J]. SENSORS, 2019, 19 (14)
  • [7] Optical Spectroscopy for Analysis and Monitoring of Metalworking Fluids
    Kiefer, Johannes
    Seidel, Benedikt
    Meyer, Daniel
    [J]. APPLIED SPECTROSCOPY, 2018, 72 (12) : 1790 - 1797
  • [8] High-sensitivity distinguishing and detection method for wear debris in oil of marine machinery
    Ma, Laihao
    Shi, Haotian
    Zhang, Hongpeng
    Li, Guobin
    Shen, Yan
    Zeng, Naibin
    [J]. OCEAN ENGINEERING, 2020, 215 (215)
  • [9] Oil Metal Debris Detection Sensor Using Ferrite Core and Flat Channel for Sensitivity Improvement and High Throughput
    Ma, Laihao
    Zhang, Hongpeng
    Qiao, Weiliang
    Han, Xiaoshuang
    Zeng, Lin
    Shi, Haotian
    [J]. IEEE SENSORS JOURNAL, 2020, 20 (13) : 7303 - 7309
  • [10] Multifunctional Detection Sensor and Sensitivity Improvement of a Double Solenoid Coil Sensor
    Ma, Laihao
    Xu, Zhiwei
    Zhang, Hongpeng
    Qiao, Weiliang
    Chen, Haiquan
    [J]. MICROMACHINES, 2019, 10 (06)